Component guide · Intermediate · 3 min read
Hi-Link Isolated DC-DC Converter Modules (B0505, B0512, URB4805)

Wiring and Uses
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
Hi-Link isolated DC-DC modules give an output that is electrically separated from the input, with no shared ground. B0505 and B0512 parts make 5 V or 12 V from 5 V at 1 to 2 W, and URB parts give a regulated output from wide inputs like 48 V. Isolation breaks ground loops and protects microcontrollers in RS485, sensor and industrial circuits.
Key specs at a glance
- Isolation
- About 1,000 to 1,500 V DC
- Power
- 1 W or 2 W (B series), 3 to 6 W (URB)
- Input
- Fixed, e.g. 5 V (B0505) or 18 to 75 V (URB4805)
- Output
- 5, 12 V and others
- Regulation
- B series unregulated (LS versions regulated); URB regulated
- Package
- SIP-4 or DIP
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 11W Isolated DC-DC Converter Module₹119
Option 2Hi-Link Isolated DC-DC Converter Family₹200
Option 3Isolated DC-DC Converter Module (1W / 2W)₹78
What the Hi-Link isolated DC-DC module is
An isolated DC-DC module converts one DC voltage to another through a small internal transformer, so its output has no electrical connection to its input. That isolation breaks ground loops and protects controllers.
Unregulated B series outputs rise at light load; keep at least 10 percent load or choose the regulated LS version. Input and output grounds must stay separate, or the isolation is lost.
Hi-Link isolated DC-DC module pinout
The pins on the Hi-Link isolated DC-DC module and what each one does.
| Pin | Function |
|---|---|
| VIN / GND (in) | Input side |
| +VO / 0V (out) | Isolated output |
| NC | Not connected (some) |
- VIN / GND (in)
- Input side
- +VO / 0V (out)
- Isolated output
- NC
- Not connected (some)
Wiring the Hi-Link isolated DC-DC module
Connect the Hi-Link isolated DC-DC module like this.
| Hi-Link isolated DC-DC module pin | B0505 example | URB example |
|---|---|---|
| Input | 5 V from the controller side | 48 V bus (URB4805) |
| Output | Isolated RS485 transceiver supply | 5 V logic |
- Input
- B0505 example:
- 5 V from the controller side
- URB example:
- 48 V bus (URB4805)
- Output
- B0505 example:
- Isolated RS485 transceiver supply
- URB example:
- 5 V logic
Example code
A minimal sketch to check the part works.
Keep the two grounds apart. Add the input and output
capacitors from the datasheet (often 4.7 to 10 uF).Setup and tuning
fit the input and output capacitors from the datasheet close to the pins.
unregulated B-series parts rise well above their rated voltage with little load; add a small load resistor or use a regulated LS or URB part.
keep a clear gap between input and output copper so the isolation is not bridged.
never join input ground and output ground, or the isolation is lost.
a 1 W 5 V module gives only 200 mA.
What you need
Shop this list5 of 5 found in our store · ₹963
1W Isolated DC-DC Converter Module: the part this guide covers1W Isolated DC-DC Converter Module₹119
Hi-Link Isolated DC-DC Converter Family: another version this guide coversHi-Link Isolated DC-DC Converter Family₹200
Isolated DC-DC Converter Module (1W / 2W): another version this guide coversIsolated DC-DC Converter Module (1W / 2W)₹78
Digital multimeter: to check supply and signal voltagesDigital Multimeter₹177
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389
Alternatives and when to choose them
- Hi-Link AC-DC modules: mains input.
- RS485 and RS232: isolated transceivers.
- Voltage regulators.
Common mistakes to avoid
- Joining the input and output grounds, which removes the isolation.
- Running an unregulated module with no load, so the output voltage is too high.
- Expecting more than the watt rating.
- Placing input and output tracks close together on the PCB.
Frequently asked questions
Why use an isolated DC-DC module?
To break ground loops between systems and protect the controller, for example on RS485 lines or sensors on long cables.
Is the output regulated?
The plain B-series parts are not, so the voltage changes with load. LS and URB parts are regulated.
How much current does a 1 W module give?
About 200 mA at 5 V. A 2 W module gives about 400 mA.
Can it power an ESP32?
Only very light loads, because Wi-Fi peaks go above 1 W. Use a larger regulated module for an ESP32.
Is there a module for 48 V systems?
Yes. The URB4805 family accepts about 18 to 75 V and gives a regulated 5 V output.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.