Component guide · Intermediate · 3 min read
MAX30100 Pulse Oximeter Sensor

Pinout, Wiring and Code
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
The MAX30100 is an optical heart rate and blood oxygen (SpO2) sensor. It shines red and infrared light into a fingertip and measures the reflected light, and talks over I2C at address 0x57. Many cheap modules pull the I2C lines up to 1.8 V, which stops them working with 5 V boards until the pull-ups are moved to 3.3 V. It is the older sibling of the MAX30102.
Key specs at a glance
- Measures
- Heart rate and SpO2 (red + IR LEDs and photodetector)
- Interface
- I2C, address 0x57
- Supply
- Module 3.3 to 5 V in; chip runs at 1.8 V and 3.3 V
- Current
- About 0.6 to 1.2 mA, up to 50 mA LED pulses
- Sample rate
- 50 to 1000 samples per second
- Built-in
- Ambient light cancellation, temperature sensor
What the MAX30100 sensor is
The sensor measures how much light passes back through the blood in your fingertip. Each heartbeat changes the blood volume, which shows up as a small ripple, and the ratio of red to infrared absorption gives an estimate of oxygen saturation.
Most purple MAX30100 boards have 4.7 kΩ pull-ups tied to the 1.8 V rail. Arduino boards then cannot read it. The fix is to cut the pull-ups' link to 1.8 V and connect them to 3.3 V, or add external 4.7 kΩ pull-ups to 3.3 V. This is a learning module, not a medical device. Do not use it to diagnose or monitor a health condition.
MAX30100 sensor pinout
The pins on the MAX30100 sensor and what each one does.
| Pin | Function |
|---|---|
| VIN | Supply, 3.3 to 5 V (regulators make 1.8 V and 3.3 V) |
| GND | Ground |
| SCL | I2C clock |
| SDA | I2C data |
| INT | Interrupt output, active low (optional) |
- VIN
- Supply, 3.3 to 5 V (regulators make 1.8 V and 3.3 V)
- GND
- Ground
- SCL
- I2C clock
- SDA
- I2C data
- INT
- Interrupt output, active low (optional)
Wiring the MAX30100 sensor
If an I2C scanner does not find 0x57, check the pull-ups: measure SDA to GND with the module powered. Around 1.8 V means the pull-up fix is needed.
| MAX30100 sensor pin | Arduino Uno | ESP32 |
|---|---|---|
| VIN | 5V | 3V3 |
| GND | GND | GND |
| SCL | A5 (with pull-up fix) | GPIO 22 |
| SDA | A4 (with pull-up fix) | GPIO 21 |
| INT | D2 (optional) | GPIO 19 (optional) |
- VIN
- Arduino Uno:
- 5V
- ESP32:
- 3V3
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- SCL
- Arduino Uno:
- A5 (with pull-up fix)
- ESP32:
- GPIO 22
- SDA
- Arduino Uno:
- A4 (with pull-up fix)
- ESP32:
- GPIO 21
- INT
- Arduino Uno:
- D2 (optional)
- ESP32:
- GPIO 19 (optional)
Example code
Install MAX30100lib by OXullo Intersecans. Do not use delay() in loop(); the library needs update() called many times a second.
#include <Wire.h>
#include "MAX30100_PulseOximeter.h"
PulseOximeter pox;
uint32_t last = 0;
void onBeat() { Serial.println("Beat"); }
void setup() {
Serial.begin(115200);
if (!pox.begin()) { Serial.println("MAX30100 not found"); while (1); }
pox.setIRLedCurrent(MAX30100_LED_CURR_7_6MA);
pox.setOnBeatDetectedCallback(onBeat);
}
void loop() {
pox.update(); // call as often as possible
if (millis() - last > 1000) {
Serial.print("HR: "); Serial.print(pox.getHeartRate());
Serial.print(" bpm SpO2: "); Serial.print(pox.getSpO2()); Serial.println(" %");
last = millis();
}
}Setup and tuning
if your board ties them to 1.8 V.
rest the finger lightly; pressing hard squeezes the blood out and flattens the signal.
cover the finger and sensor from room light.
movement swamps the small pulse signal; wait 10 to 20 seconds for readings to settle.
What you need
Shop this list5 of 6 found in our store · ₹912
Generic MAX30100 Pulse Oximeter Heart Rate Sensor Module – I2C Interface: the part this guide coversMAX30100 Pulse Oximeter Heart Rate Sensor Module – I2C Interface₹85- Uno R3 development board: the controller used in the wiring tableFind this part
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389
0.96 inch OLED display 128x64: to show readings without a computer0.96" OLED Display 128x64₹139Closest match, check the specs
Resistor assortment kit: 4.7 kΩ pull-ups to 3.3 V if neededResistor Assortment Kit₹250
Dupont jumper wires: for the connectionsDupont Jumper Wires (40 pcs)₹49Closest match, check the specs
Alternatives and when to choose them
- MAX30102 heart rate sensor: the newer chip, with a bigger FIFO, better resolution and fewer module problems.
- AD8232 ECG module: records the heart's electrical signal with electrodes instead of light.
- ECG, EMG and biopotential sensors: other ways to read signals from the body.
Common mistakes to avoid
- Using a module with 1.8 V pull-ups on a 5 V Arduino without the pull-up fix.
- Pressing the finger hard on the sensor.
- Using delay() in loop(), which starves the library and gives no readings.
- Treating the SpO2 value as a medical reading.
Frequently asked questions
Why does my MAX30100 not show up on I2C?
Most often the module's pull-ups go to 1.8 V. Move them to 3.3 V or add external 4.7 kΩ pull-ups to 3.3 V.
What is the MAX30100 I2C address?
0x57, the same as the MAX30102.
MAX30100 or MAX30102?
Choose the MAX30102 for new projects; it has better resolution and is easier to get working.
Why are my readings zero?
update() is not called often enough, the finger is moving, or light is leaking in.
Is it accurate enough for medical use?
No. It is good for learning and demos only.
Parts for this guide
Keep learning
Sources
- MAX30100 pulse oximeter and heart-rate sensor datasheet (Maxim Integrated)
- MAX30100lib library documentation (OXullo Intersecans)
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.