Component guide · Intermediate · 3 min read
Winsen MH-Z14A, MH-Z16 and MH-410D NDIR CO2 Sensors

UART, PWM and Analog Wiring
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
The MH-Z14A and MH-Z16 are Winsen NDIR CO2 sensors that use the same UART commands as the MH-Z19. The MH-Z14A is a long board with 0 to 5000 ppm range and UART, PWM and analog outputs. The MH-Z16 has a larger optical chamber with ranges up to 10 percent volume for greenhouses and fermentation. The MH-410D is an NDIR module for industrial CO2.
Key specs at a glance
- Supply
- 4.5 to 5.5 V
- Range
- 0 to 2000, 5000 or 10,000 ppm (MH-Z14A); up to 10% vol (MH-Z16)
- Interface
- UART 9600 (3.3 V logic), PWM, analog 0.4 to 2 V
- Accuracy
- About plus or minus 50 ppm plus 5% of reading
- Warm-up
- About 3 minutes
- Current
- Under 100 to 150 mA average
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Winsen MH-Z14 NDIR CO2 Sensor Module – UART/Analog/PWM Output₹3,611
Option 2Winsen MH-Z14A IR CO2 Sensor Module – UART/Analog/PWM Output₹3,396
Option 3Winsen MH-Z16 NDIR CO2 Sensor Module – UART/PWM Output₹3,839
Option 4MH-Z16 NDIR CO2 Sensor 0-1% Volume – UART/PWM Output₹5,179
Option 5Winsen MH-410D NDIR CO2 Gas Sensor – UART/Analog Output₹10,049
What the MH-Z14, MH-Z16 and MH-410D NDIR CO2 sensors is
The Winsen MH-Z14 and MH-Z16 are NDIR CO2 sensors with UART, PWM and analog outputs; the MH-Z16 measures up to higher ranges for greenhouses and industry.
Send FF 01 86 00 00 00 00 00 79 and the sensor replies with nine bytes; CO2 ppm is byte 2 x 256 + byte 3.
Automatic baseline correction assumes the sensor sees 400 ppm at least once a day. Turn it off in greenhouses that never air out.
MH-Z14, MH-Z16 and MH-410D NDIR CO2 sensors pinout
The pins on the MH-Z14, MH-Z16 and MH-410D NDIR CO2 sensors and what each one does.
| Pin | Function |
|---|---|
| Vin | 5 V |
| GND | Ground |
| TXD / RXD | UART |
| PWM | Pulse output |
| Vo | Analog output |
- Vin
- 5 V
- GND
- Ground
- TXD / RXD
- UART
- PWM
- Pulse output
- Vo
- Analog output
Wiring the MH-Z14, MH-Z16 and MH-410D NDIR CO2 sensors
Connect the MH-Z14, MH-Z16 and MH-410D NDIR CO2 sensors like this.
| MH-Z14, MH-Z16 and MH-410D NDIR CO2 sensors pin | Arduino Uno | ESP32 |
|---|---|---|
| Module VCC | 5 V | 5 V (VIN) |
| Module GND | GND | GND |
| Module TXD | D10 (SoftwareSerial RX) | GPIO 16 (RX2) |
| Module RXD | D11 through a divider if the module is 3.3 V | GPIO 17 (TX2) |
- Module VCC
- Arduino Uno:
- 5 V
- ESP32:
- 5 V (VIN)
- Module GND
- Arduino Uno:
- GND
- ESP32:
- GND
- Module TXD
- Arduino Uno:
- D10 (SoftwareSerial RX)
- ESP32:
- GPIO 16 (RX2)
- Module RXD
- Arduino Uno:
- D11 through a divider if the module is 3.3 V
- ESP32:
- GPIO 17 (TX2)
Example code
A minimal sketch to check the part works.
const uint8_t CMD[9] = {0xFF, 0x01, 0x86, 0, 0, 0, 0, 0, 0x79};
void setup() {
Serial.begin(115200);
Serial2.begin(9600, SERIAL_8N1, 16, 17);
}
void loop() {
Serial2.write(CMD, 9);
uint8_t r[9];
if (Serial2.readBytes(r, 9) == 9 && r[0] == 0xFF && r[1] == 0x86) {
Serial.print(r[2] * 256 + r[3]); Serial.println(" ppm");
}
delay(5000);
}Setup and tuning
feed 4.5 to 5.5 V at about 150 mA.
read at 9600 baud with the read command; use 3.3 V levels as rated.
wait about 3 minutes after power-up.
auto baseline assumes fresh air daily; turn it off in greenhouses.
let air reach the sensor freely.
What you need
Shop this list9 of 10 found in our store · ₹29,499
Winsen MH-Z14 NDIR CO2 Sensor Module – UART/Analog/PWM Output: the part this guide coversWinsen MH-Z14 NDIR CO2 Sensor Module – UART/Analog/PWM Output₹3,611
Winsen MH-Z14A IR CO2 Sensor Module – UART/Analog/PWM Output: another version this guide coversWinsen MH-Z14A IR CO2 Sensor Module – UART/Analog/PWM Output₹3,396
Winsen MH-Z16 NDIR CO2 Sensor Module – UART/PWM Output: another version this guide coversWinsen MH-Z16 NDIR CO2 Sensor Module – UART/PWM Output₹3,839
MH-Z16 NDIR CO2 Sensor 0-1% Volume – UART/PWM Output: another version this guide coversMH-Z16 NDIR CO2 Sensor 0-1% Volume – UART/PWM Output₹5,179
Winsen MH-410D NDIR CO2 Gas Sensor – UART/Analog Output: another version this guide coversWinsen MH-410D NDIR CO2 Gas Sensor – UART/Analog Output₹10,049
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389- Uno R3 development board: the controller used in the wiring tableFind this part
USB to TTL serial converter: to talk to the module from a PCUSB to TTL Serial Converter (CH340G / CP2102 / FT232RL / PL2303)₹85Closest match, check the specs
0.96 inch OLED display 128x64: to show readings without a computer0.96" OLED Display 128x64₹139Closest match, check the specs
MH-Z19C NDIR CO2 sensor: the popular low-cost NDIR CO2 sensorWinsen MH-Z19C NDIR CO2 Sensor HVAC/IAQ – UART/PWM Output₹2,812Closest match, check the specs
Alternatives and when to choose them
- MH-Z19 sensor: smaller, same commands.
- CO2 NDIR sensors: background and choosing.
- SCD30 sensor: I2C with temperature and humidity.
Common mistakes to avoid
- Leaving auto-calibration on in greenhouses.
- Weak 5 V supply.
- Reading before warm-up.
- Blocking air flow.
Frequently asked questions
What range do the MH-Z14 and MH-Z16 measure?
Commonly 0 to 5000 ppm; MH-Z16 versions reach up to 10,000 ppm or more.
Why do readings drift down?
Auto baseline calibration assumes 400 ppm fresh air; turn it off if needed.
Can I read it with ESP32?
Yes. Read it over UART at 9600 baud, powering the sensor from 5 V.
How long does it warm up?
About 3 minutes after power-up before readings are reliable.
Is NDIR better than chemical CO2 sensors?
Yes. NDIR measures CO2 directly with infrared, so it is more accurate and stable.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.