Component guide · Intermediate · 3 min read
MQ-131 Ozone Gas Sensor (Low and High Concentration) and Mikroe Ozone 2 Click

By Geekobot Learning Team · Updated 29 Oct 2026
On this page
The MQ-131 is a metal-oxide ozone sensor. The low-concentration black version reads about 10 ppb to 2 ppm for air quality, while the high-concentration version reads about 10 to 1000 ppm for ozone generators. Unlike most MQ sensors its resistance rises with ozone. It needs a 5 V heater, a long warm-up and calibration to give useful numbers.
Key specs at a glance
- Heater
- 5 V, about 150 to 200 mA
- Range
- 10 ppb to 2 ppm (low), 10 to 1000 ppm (high)
- Output
- Analog (module adds digital threshold)
- Warm-up
- Minutes for a reading; 24 to 48 hours burn-in
- Load resistor
- On the module, often adjustable
- Cross-sensitivity
- Cl2 and NO2
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1MQ-131 Ozone Gas Detection Sensor Module – 10PPB-2PPM Range, Analog & Digital Output₹1,779
Option 2MQ-131 Ozone Gas Detection Sensor Module – Analog & TTL Output₹1,481
Option 3MQ-131 Ozone Gas Detection Sensor – 10-1000 ppm, Analog Output₹719
Option 4Winsen MQ131 High-Concentration Ozone Gas Sensor – Semiconductor Sensor₹2,099
Option 5Mikroe OZONE 2 CLICK (Mikroe-2767) – MQ131 Ozone (O₃) Gas Sensor Board, Analog & SPI, mikroBUS₹4,069
What the MQ-131 ozone sensor is
The MQ131 is a metal-oxide ozone sensor whose resistance changes with ozone concentration, used in ozone generator monitors and air quality projects.
Check which version you have before choosing the curve: the low-concentration one is for room air, the high one for ozone machines.
Ozone is reactive and breaks down fast, so place the sensor where the air moves past it.
MQ-131 ozone sensor pinout
The pins on the MQ-131 ozone sensor and what each one does.
| Pin | Function |
|---|---|
| VCC | 5 V |
| GND | Ground |
| AO | Analog output |
| DO | Threshold output |
- VCC
- 5 V
- GND
- Ground
- AO
- Analog output
- DO
- Threshold output
Wiring the MQ-131 ozone sensor
The heater draws about 150 mA or more. Do not power it from an ESP32 3.3 V pin.
| MQ-131 ozone sensor pin | Arduino Uno | ESP32 |
|---|---|---|
| VCC | 5 V | 5 V (VIN) |
| GND | GND | GND |
| AO | A0 | GPIO 34 via 10 k / 20 k divider |
| DO | D2 | GPIO 27 |
- VCC
- Arduino Uno:
- 5 V
- ESP32:
- 5 V (VIN)
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- AO
- Arduino Uno:
- A0
- ESP32:
- GPIO 34 via 10 k / 20 k divider
- DO
- Arduino Uno:
- D2
- ESP32:
- GPIO 27
Example code
For ozone, Rs/R0 rises as concentration rises.
const float RL = 10.0; // load resistor on the module, kilo-ohms (check yours)
float R0 = 10.0; // sensor resistance in clean air, set by calibration
float rs() {
long sum = 0;
for (int i = 0; i < 32; i++) sum += analogRead(A0);
float v = sum / 32.0 * 5.0 / 1023.0;
return RL * (5.0 - v) / v;
}
void setup() {
Serial.begin(115200);
delay(120000); // let the heater warm up (much longer for the first use)
R0 = rs(); // calibrate in clean air
}
void loop() {
float ratio = rs() / R0; // look up ppm from the datasheet curve for your gas
Serial.print("Rs/R0 = "); Serial.println(ratio, 3);
delay(1000);
}Setup and tuning
feed 5 V to the heater; it draws about 150 mA or more.
read the output through the module's load resistor on an analog pin.
burn in for 24 to 48 hours on first use.
use the datasheet curve and a known reference for accuracy.
ozone is harmful; ventilate and do not breathe it.
What you need
Shop this list9 of 10 found in our store · ₹10,876
MQ-131 Ozone Gas Detection Sensor Module – 10PPB-2PPM Range, Analog & Digital Output: the part this guide coversMQ-131 Ozone Gas Detection Sensor Module – 10PPB-2PPM Range, Analog & Digital Output₹1,779
MQ-131 Ozone Gas Detection Sensor Module – Analog & TTL Output: another version this guide coversMQ-131 Ozone Gas Detection Sensor Module – Analog & TTL Output₹1,481
MQ-131 Ozone Gas Detection Sensor – 10-1000 ppm, Analog Output: another version this guide coversMQ-131 Ozone Gas Detection Sensor – 10-1000 ppm, Analog Output₹719
Winsen MQ131 High-Concentration Ozone Gas Sensor – Semiconductor Sensor: another version this guide coversWinsen MQ131 High-Concentration Ozone Gas Sensor – Semiconductor Sensor₹2,099
Mikroe OZONE 2 CLICK (Mikroe-2767) – MQ131 Ozone (O₃) Gas Sensor Board, Analog & SPI, mikroBUS: another version this guide coversMikroe OZONE 2 CLICK (Mikroe-2767) – MQ131 Ozone (O₃) Gas Sensor Board, Analog & SPI, mikroBUS₹4,069- Uno R3 development board: the controller used in the wiring tableFind this part
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389
ADS1115 16-bit 4-channel ADC module: to read small sensor voltages accuratelyADS1115 16-Bit 4-Channel ADC Module₹199
Buzzer module 3.3-5 V: for an audible alarmBuzzer Module 3.3–5V₹27
MQ-135 air quality sensor module: a low-cost general air quality sensorMQ-135 Air Quality & Gas Detector Sensor Module for Arduino – Analog & TTL Output₹114Closest match, check the specs
Alternatives and when to choose them
- MQ gas sensors: the whole MQ family.
- DFRobot Gravity ozone: calibrated I2C ozone.
- Electrochemical gas sensors: ME3-O3 and others.
Common mistakes to avoid
- Reading before warm-up.
- Using it as a safety device.
- Breathing ozone during tests.
- Powering the heater from a GPIO.
Frequently asked questions
Can the MQ131 measure exact ozone ppm?
Only roughly, after calibration against a known ozone level.
Why do readings drift?
Temperature, humidity and incomplete warm-up all shift the reading.
Is ozone dangerous?
Yes. Ozone irritates the lungs, so ventilate the space and limit exposure.
Can I power the heater from a pin?
No. The heater draws too much current; feed it from the 5 V rail.
Which MQ131 version should I use?
Low and high concentration versions exist; pick by range.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.