Component guide · Intermediate · 4 min read
Radar Level Sensors

Renke RS-RAD, FirstRate FSTRD-905, NanoRadar WTR10 and Hi-Link LD2413, LD7901B, LD8001
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
Radar level sensors measure the distance to a liquid or solid surface with microwaves, unaffected by temperature, wind, vapour or foam that upset ultrasonic sensors. The Renke and FirstRate units read up to 65 m and output RS485 Modbus; the NanoRadar WTR10 reads 0.1 to 30 m with about 3 mm accuracy. Hi-Link's LD8001 and LD7901B are 80 GHz modules for building your own.
Key specs at a glance
- Frequency
- 24 GHz (LD2413) or 77 to 81 GHz (LD8001, LD7901B, WTR10)
- Range
- Up to 30 m (WTR10), 65 m (Renke, FirstRate)
- Accuracy
- About plus or minus 3 to 10 mm
- Output
- RS485 Modbus (industrial); UART, SPI or I2C (modules)
- Supply
- About 12 to 24 V (industrial), 3.3 to 5 V (modules)
- Beam
- Narrow at 80 GHz, about 3 to 8 degrees
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Renke RS-RAD-N01-1-EX Radar Level Sensor, RS485, 0.1-65m Range, IP67₹29,479
Option 2FirstRate FSTRD-905 Radar Tank Level Sensor, Range: 0.1m-65m, RS485 Output, 10m Cable₹32,989
Option 3NanoRadar WTR10 60GHz FMCW Water Level Radar – 0.1-30m Range, 3mm Accuracy₹26,169
Option 4Hi-Link HLK-LD2413 Liquid Level Detection Radar Sensor (23GHz-27GHz)₹1,989
Option 5Hi-Link HLK-LD7901B Liquid Level Detection Radar Sensor (79GHz ~ 81GHz)₹7,561
Option 6Hi-Link HLK-LD8001 Liquid Level Detection Radar Sensor (79-81GHz) – SPI/UART/I2C Interface₹4,889
What the Radar level sensors (24 GHz and 80 GHz) is
Radar level sensors measure liquid or solid levels in tanks and silos using 26 GHz or 80 GHz radar, without contact, and output 4 to 20 mA, HART or RS485.
80 GHz radars have a narrow beam, so they fit narrow tanks and ignore walls and ladders. Install them square to the surface and away from inlets where liquid pours in.
Level is tank height minus the measured distance. Most industrial units do this for you once you set the empty-tank height.
Radar level sensors (24 GHz and 80 GHz) pinout
The pins on the Radar level sensors (24 GHz and 80 GHz) and what each one does.
| Pin | Function |
|---|---|
| V+ | Supply |
| GND | Ground |
| A+ / B- | RS485 (industrial) |
| TX / RX or SDA / SCL | Modules |
- V+
- Supply
- GND
- Ground
- A+ / B-
- RS485 (industrial)
- TX / RX or SDA / SCL
- Modules
Wiring the Radar level sensors (24 GHz and 80 GHz)
Connect the Radar level sensors (24 GHz and 80 GHz) like this.
| Radar level sensors (24 GHz and 80 GHz) pin | Arduino Uno | ESP32 |
|---|---|---|
| V+ (red/brown) | 12 V supply + | 12 V supply + |
| V- / GND (black) | Supply - and board GND | Supply - and board GND |
| A+ (yellow) | MAX485 A | MAX485 A |
| B- (white/blue) | MAX485 B | MAX485 B |
| MAX485 RO / DI | D10 / D11 (SoftwareSerial) | GPIO 16 / GPIO 17 |
| MAX485 DE+RE | D4 | GPIO 4 |
- V+ (red/brown)
- Arduino Uno:
- 12 V supply +
- ESP32:
- 12 V supply +
- V- / GND (black)
- Arduino Uno:
- Supply - and board GND
- ESP32:
- Supply - and board GND
- A+ (yellow)
- Arduino Uno:
- MAX485 A
- ESP32:
- MAX485 A
- B- (white/blue)
- Arduino Uno:
- MAX485 B
- ESP32:
- MAX485 B
- MAX485 RO / DI
- Arduino Uno:
- D10 / D11 (SoftwareSerial)
- ESP32:
- GPIO 16 / GPIO 17
- MAX485 DE+RE
- Arduino Uno:
- D4
- ESP32:
- GPIO 4
Example code
Check the manual for which register holds the distance or level, and its scale.
// Read an RS485 Modbus RTU sensor with a MAX485 module (ModbusMaster library)
#include <ModbusMaster.h>
const int DE_RE = 4; // tie DE and RE together
ModbusMaster node;
void preTx() { digitalWrite(DE_RE, HIGH); }
void postTx() { digitalWrite(DE_RE, LOW); }
void setup() {
Serial.begin(115200);
Serial2.begin(9600, SERIAL_8N1, 16, 17);
pinMode(DE_RE, OUTPUT); postTx();
node.begin(1, Serial2); // slave address 1 (check the manual)
node.preTransmission(preTx);
node.postTransmission(postTx);
}
void loop() {
if (node.readHoldingRegisters(0x0000, 2) == node.ku8MBSuccess) {
Serial.print("Reg 0: "); Serial.print(node.getResponseBuffer(0));
Serial.print(" Reg 1: "); Serial.println(node.getResponseBuffer(1));
} else {
Serial.println("No reply - check A/B, address and baud");
}
delay(1000);
}Setup and tuning
fit on top of the tank, away from the inlet and walls, aimed straight down.
80 GHz units have narrow beams for small tanks and obstacles; 26 GHz suits larger vessels.
wire 4 to 20 mA to a PLC or use RS485 Modbus.
set empty and full distances, and map false echoes from fittings.
most are 24 V DC two-wire loop powered.
What you need
Shop this list11 of 11 found in our store · ₹1,11,293
Renke RS-RAD-N01-1-EX Radar Level Sensor, RS485, 0.1-65m Range, IP67: the part this guide coversRenke RS-RAD-N01-1-EX Radar Level Sensor, RS485, 0.1-65m Range, IP67₹29,479
FirstRate FSTRD-905 Radar Tank Level Sensor, Range: 0.1m-65m, RS485 Output, 10m Cable: another version this guide coversFirstRate FSTRD-905 Radar Tank Level Sensor, Range: 0.1m-65m, RS485 Output, 10m Cable₹32,989
NanoRadar WTR10 60GHz FMCW Water Level Radar – 0.1-30m Range, 3mm Accuracy: another version this guide coversNanoRadar WTR10 60GHz FMCW Water Level Radar – 0.1-30m Range, 3mm Accuracy₹26,169
Hi-Link HLK-LD2413 Liquid Level Detection Radar Sensor (23GHz-27GHz): another version this guide coversHi-Link HLK-LD2413 Liquid Level Detection Radar Sensor (23GHz-27GHz)₹1,989
Hi-Link HLK-LD7901B Liquid Level Detection Radar Sensor (79GHz ~ 81GHz): another version this guide coversHi-Link HLK-LD7901B Liquid Level Detection Radar Sensor (79GHz ~ 81GHz)₹7,561
Hi-Link HLK-LD8001 Liquid Level Detection Radar Sensor (79-81GHz) – SPI/UART/I2C Interface: another version this guide coversHi-Link HLK-LD8001 Liquid Level Detection Radar Sensor (79-81GHz) – SPI/UART/I2C Interface₹4,889
Hi-Link HLK-LD8001B Liquid Level Detection Radar Sensor (79-81GHz) – SPI/UART/I2C Interface: another version this guide coversHi-Link HLK-LD8001B Liquid Level Detection Radar Sensor (79-81GHz) – SPI/UART/I2C Interface₹5,829
MAX485 RS-485 to TTL module: to read RS485 versions from a microcontrollerMAX485 RS-485 to TTL Module₹28
USB to RS485 converter adapter: to test RS485 versions from a PCUSB to RS485 Converter Adapter₹74
SMPS power supply in metal enclosure (5/12/24 V): a 12 V or 24 V supplySMPS Power Supply, Metal Enclosure (5V / 12V / 24V)₹298Closest match, check the specs
DYP A02YYUW waterproof ultrasonic sensor: a cheaper ultrasonic level optionDYP A02YYUW Waterproof Ultrasonic Sensor UART IP67 3–450cm₹1,989Closest match, check the specs
Alternatives and when to choose them
- Ultrasonic level sensors: cheaper, short tanks.
- Submersible transmitters: pressure-based, in the liquid.
- Liquid level sensors: overview of all methods.
Common mistakes to avoid
- Mounting next to the inlet.
- Skipping false echo mapping.
- Wrong empty and full settings.
- Using wide-beam sensors in narrow tanks.
Frequently asked questions
Why use radar instead of ultrasonic for level?
Radar is not affected by temperature, vapour or dust, so it is more reliable.
Why does my radar read the wrong level?
False echoes from fittings or the tank wall; run false echo mapping.
Can radar measure solids like grain?
Yes, many radar sensors measure powders and grains in silos.
How do I read 4 to 20 mA in a PLC?
Wire it to an analog input and scale 4 mA as empty and 20 mA as full.
Does foam affect radar?
Heavy foam can absorb radar signals; test in your process.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.