Component guide · Intermediate · 4 min read
PUSR USR-TCP232, USR-N510 and USR-W610 Serial Servers

Setup and Modes
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
PUSR makes serial to network converters in every size: the USR-TCP232-T2 and ED2 are small TTL modules for your own boards, the USR-N510 is a boxed RS232/RS485 serial server, the USR-W610 adds Wi-Fi and the USR-WIFI232-B2 is a UART to Wi-Fi module. All are set up with PUSR's USR-VCOM and setup tools or a web page, then run as TCP server, TCP client, UDP or Modbus gateway.
Key specs at a glance
- USR-TCP232-T2 / ED2
- TTL UART to Ethernet module, 3.3 V
- USR-N510
- RS232/RS485/RS422 to Ethernet serial server
- USR-W610
- RS232/RS485 to Wi-Fi and Ethernet, can act as a router
- USR-WIFI232-B2
- UART to Wi-Fi module, AT commands
- USR-M100
- Edge gateway with RS485, IO and Modbus/MQTT logic
- USR-LG206
- LoRa data transfer unit for RS232/RS485 links
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1USR-TCP232-T2 Serial to Ethernet Module₹1,097
Option 2PUSR Serial to Ethernet Converter₹2,000
Option 3PUSR Serial Device Server (1 / 2 / 4 Port)₹4,550
Option 4PUSR Industrial Wi-Fi Serial Server and Router₹4,150
Option 5PUSR USR-WIFI232-B2 Industrial UART to WiFi Module₹6,919
Option 6PUSR Edge IoT Gateway and Controller₹8,700
What the PUSR USR-TCP232 and USR-N510 serial server is
The T2 and ED2 modules sit on a microcontroller's UART and handle the TCP/IP stack, so a Uno or STM32 gets networking with plain serial writes. The boxed servers take RS485 field wiring and 5 to 36 V power.
The USR-M100 goes further: it polls Modbus devices itself and publishes data over MQTT to a cloud or Node-RED. The USR-LG206 pairs with another LG206 to carry an RS485 link over LoRa where cables are impractical.
PUSR USR-TCP232 and USR-N510 serial server pinout
The pins on the PUSR USR-TCP232 and USR-N510 serial server and what each one does.
| Pin | Function |
|---|---|
| TXD / RXD (modules) | 3.3 V TTL UART to the controller |
| RST / Reload (modules) | Reset and factory restore |
| A+ / B- (servers) | RS485 bus |
| DB9 (servers) | RS232 |
| RJ45 | Ethernet |
| DC IN | 5 to 36 V on boxed units |
- TXD / RXD (modules)
- 3.3 V TTL UART to the controller
- RST / Reload (modules)
- Reset and factory restore
- A+ / B- (servers)
- RS485 bus
- DB9 (servers)
- RS232
- RJ45
- Ethernet
- DC IN
- 5 to 36 V on boxed units
Wiring the PUSR USR-TCP232 and USR-N510 serial server
This table is for the USR-TCP232-T2 module, which is 3.3 V only. Boxed servers wire A+ and B- to the RS485 bus and take 12 or 24 V on the power terminal.
| PUSR USR-TCP232 and USR-N510 serial server pin | Arduino Uno | ESP32 |
|---|---|---|
| VCC | 3.3V (not 5V) | 3V3 |
| GND | GND | GND |
| RXD | D1 TX via divider | GPIO 17 (TX2) |
| TXD | D0 RX | GPIO 16 (RX2) |
| RJ45 | Router | Router |
- VCC
- Arduino Uno:
- 3.3V (not 5V)
- ESP32:
- 3V3
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- RXD
- Arduino Uno:
- D1 TX via divider
- ESP32:
- GPIO 17 (TX2)
- TXD
- Arduino Uno:
- D0 RX
- ESP32:
- GPIO 16 (RX2)
- RJ45
- Arduino Uno:
- Router
- ESP32:
- Router
Example code
Set the module to TCP client mode with your server's IP and port using the PUSR setup software first; after that every byte on the UART is sent over the network.
HardwareSerial usr(2);
void setup() {
usr.begin(115200, SERIAL_8N1, 16, 17); // match the module's serial settings
}
void loop() {
float t = 27.5; // replace with a real sensor value
usr.printf("{\"temp\":%.1f}\n", t); // module forwards it to the TCP server
delay(10000);
}Setup and tuning
PUSR's setup tool finds devices on the LAN; most also have a web page at 192.168.0.7.
TCP server for virtual COM, TCP client to push to a server, Modbus TCP to RTU for SCADA.
enable these in client mode so a server knows which device connected.
keep the latest firmware for stable Wi-Fi on the W610 and WIFI232-B2.
run A, B and a ground or shield wire; A to A and B to B on every device.
fit 120 ohm resistors only at the two ends of a long bus.
daisy-chain the devices; avoid stars and long stubs.
every device on one bus needs the same baud rate and parity and a unique Modbus address.
What you need
Shop this list11 of 12 found in our store · ₹25,887
USR-TCP232-T2 Serial to Ethernet Module: the part this guide coversUSR-TCP232-T2 Serial to Ethernet Module₹1,097
PUSR Serial to Ethernet Converter: another version this guide coversPUSR Serial to Ethernet Converter₹2,000
PUSR Serial Device Server (1 / 2 / 4 Port): another version this guide coversPUSR Serial Device Server (1 / 2 / 4 Port)₹4,550
PUSR Industrial Wi-Fi Serial Server and Router: another version this guide coversPUSR Industrial Wi-Fi Serial Server and Router₹4,150
PUSR USR-WIFI232-B2 Industrial UART to WiFi Module: another version this guide coversUSR-WIFI232-B2 Industrial UART to Wi-Fi Module₹1,509
PUSR Edge IoT Gateway and Controller: another version this guide coversPUSR Edge IoT Gateway and Controller₹8,700
PUSR USR-LG206 LoRa Ad-Hoc Network Data Transfer Unit: another version this guide coversPUSR USR-LG206 LoRa Ad-Hoc Network Data Transfer Unit₹3,000
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389- Uno R3 development board: the controller used in the wiring tableFind this part
SMPS power supply in metal enclosure (5/12/24 V): a 12 or 24 V supply for the deviceSMPS Power Supply, Metal Enclosure (5V / 12V / 24V)₹298Closest match, check the specs
CAT5E Ethernet LAN cable 1 m: to connect the device to a router or switchCAT5E Ethernet LAN Cable, 1 Metre₹120Closest match, check the specs
USB to RS485 converter adapter: to test the bus from a PCUSB to RS485 Converter Adapter₹74
Alternatives and when to choose them
- RS485 to Ethernet serial servers: Waveshare equivalents.
- W5500 Ethernet: add Ethernet to a microcontroller over SPI instead.
- Serial device servers: the general idea.
Common mistakes to avoid
- 5 V on the T2 module.
- Leaving the default IP in a different subnet.
- Wrong mode: TCP client when the software expects to connect to the device.
- Baud rate mismatch between UART and module settings.
Frequently asked questions
Can a Uno use the USR-TCP232-T2?
Yes, through a level shifter; the module handles TCP/IP.
What is USR-VCOM?
PUSR's virtual COM driver for serial servers.
Does the USR-N510 support Modbus TCP?
Yes, it can convert Modbus TCP to Modbus RTU.
What does the USR-M100 add?
Edge logic: it polls devices itself and sends data by MQTT.
When is the USR-LG206 useful?
To link two RS485 sites over LoRa where cable is not practical.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.