Component guide · Intermediate · 4 min read
Wind Sensors and Anemometers

FirstRate FST200 Cup and Heated Wind Speed and Direction Sensors, SN-3003 Mini Ultrasonic Wind Sensor, NU200 200kHz Ultrasonic Transducers, DFRobot PAV3015 Air Velocity, Fluke 925, UNI-T UT363 and UT363S, HTC AVM-03 and OWON OWM5500
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
Fixed wind sensors go on a mast and report to a logger or PLC. Cup types (FirstRate FST200) are simple and give 4-20 mA or RS485; heated versions keep working in ice. Ultrasonic sensors such as the SN-3003 have no moving parts and measure speed and direction together. PAV3015 measures low air speed in ducts. Handheld anemometers are for quick HVAC and site checks.
Key specs at a glance
- Range
- 0.5-50 m/s cup, 0-30 m/s handhelds, 0-15 m/s PAV3015
- Outputs
- 4-20 mA, RS485 Modbus, pulse; I2C on PAV3015
- Supply
- 12-30V DC for mast sensors
- Direction
- 0-360° on FST200-205 and ultrasonic models
- Heated
- FST200-205A for icing conditions
- NU200
- 200 kHz transducer pairs for building ultrasonic anemometers
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1FirstRate FST200-1000 Wind Speed Sensor, 0.5-50 m/s Range, 4-20mA Output, 1.5m Cable₹6,339
Option 2FirstRate FST200-1002 Wind Speed Sensor, 0.5-50m/s, 4-20mA Output, 1.5m Cable₹5,809
Option 3FirstRate FST200-201 Wind Speed Anemometer Sensor, 0.5-50 m/s Range, 4-20mA Output, M12 Connector w/ 1.5m Cable₹7,619
Option 4FirstRate FST200-205 Wind Speed & Wind Direction Integrated Sensor, Output 4-20mA, Range 0-50m/s, 0-360°, M12 Connector with 5m Cable₹21,759
Option 5FirstRate FST200-205A Heated Wind Speed & Direction Sensor, 0-50m/s, 0-360°, RS485, M12 Connector w/ 5m Cable₹26,729
Option 6Mini Ultrasonic Wind Speed and Direction Meter SN-3003-CFSFX-N01 – RS485 Modbus₹10,119
What the Wind speed and direction sensors and handheld anemometers (FirstRate, ultrasonic, PAV3015, Fluke, UNI-T) is
Wind speed sensors and anemometers, using cups or ultrasonic sensing, measure wind speed (and sometimes direction) for weather stations, solar plants and cranes.
Mount mast sensors at least 2m above roofs or obstacles, and align the direction sensor's north mark to true north. For 4-20 mA, use a 250Ω resistor to get 1-5V at an ADC, then scale: speed = (mA - 4) / 16 × full scale.
Handhelds: vane types (Fluke 925, UT363S) suit duct and grille airflow; the split UT363S lets you hold the head in a duct and read the display outside. The NU200 transducers are parts for your own design, not a finished sensor.
Wind speed and direction sensors and handheld anemometers (FirstRate, ultrasonic, PAV3015, Fluke, UNI-T) pinout
The pins on the Wind speed and direction sensors and handheld anemometers (FirstRate, ultrasonic, PAV3015, Fluke, UNI-T) and what each one does.
| Pin | Function |
|---|---|
| Red / brown | 12-24V DC + |
| Black | GND |
| Yellow | 4-20 mA or RS485 A |
| Blue / green | RS485 B or second channel |
| M12 | Connector on FST200-201 and -205A |
- Red / brown
- 12-24V DC +
- Black
- GND
- Yellow
- 4-20 mA or RS485 A
- Blue / green
- RS485 B or second channel
- M12
- Connector on FST200-201 and -205A
Wiring the Wind speed and direction sensors and handheld anemometers (FirstRate, ultrasonic, PAV3015, Fluke, UNI-T)
Use surge protection on long mast cables; lightning is the most common cause of failure.
| Wind speed and direction sensors and handheld anemometers (FirstRate, ultrasonic, PAV3015, Fluke, UNI-T) pin | Connection | Note |
|---|---|---|
| V+ | 24V DC | Shared ground |
| 4-20 mA out | 250Ω to GND, ADC across it | 1-5V for 4-20 mA |
| RS485 A/B | Converter | Modbus RTU |
- V+
- Connection:
- 24V DC
- Note:
- Shared ground
- 4-20 mA out
- Connection:
- 250Ω to GND, ADC across it
- Note:
- 1-5V for 4-20 mA
- RS485 A/B
- Connection:
- Converter
- Note:
- Modbus RTU
Example code
Use a precision 250Ω resistor; a 1% error in the resistor is a 1% error in wind speed.
const float R = 250.0; // shunt resistor
const float FULL = 50.0; // m/s at 20 mA
void setup() { Serial.begin(9600); }
void loop() {
float v = analogRead(A0) * 5.0 / 1023.0;
float mA = v / R * 1000.0;
float speed = (mA - 4.0) / 16.0 * FULL;
if (speed < 0) speed = 0;
Serial.print(mA, 2); Serial.print(" mA ");
Serial.print(speed, 1); Serial.println(" m/s");
delay(1000);
}Setup and tuning
pulse, 0 to 5 V, 4 to 20 mA or RS485 Modbus depending on model.
count pulses with an interrupt and use the maker's factor for m/s.
mount at the top of a mast, away from buildings, ideally 10 m high for standard data.
align the wind vane's north mark.
check supply voltage for analog and RS485 versions.
What you need
Shop this list17 of 19 found in our store · ₹1,59,738
FirstRate FST200-1000 Wind Speed Sensor, 0.5-50 m/s Range, 4-20mA Output, 1.5m Cable: the part this guide coversFirstRate FST200-1000 Wind Speed Sensor, 0.5-50 m/s Range, 4-20mA Output, 1.5m Cable₹6,339
FirstRate FST200-1002 Wind Speed Sensor, 0.5-50m/s, 4-20mA Output, 1.5m Cable: another version this guide coversFirstRate FST200-1002 Wind Speed Sensor, 0.5-50m/s, 4-20mA Output, 1.5m Cable₹5,809
FirstRate FST200-201 Wind Speed Anemometer Sensor, 0.5-50 m/s Range, 4-20mA Output, M12 Connector w/ 1.5m Cable: another version this guide coversFirstRate FST200-201 Wind Speed Anemometer Sensor, 0.5-50 m/s Range, 4-20mA Output, M12 Connector w/ 1.5m Cable₹7,619
FirstRate FST200-205 Wind Speed & Wind Direction Integrated Sensor, Output 4-20mA, Range 0-50m/s, 0-360°, M12 Connector with 5m Cable: another version this guide coversFirstRate FST200-205 Wind Speed & Wind Direction Integrated Sensor, Output 4-20mA, Range 0-50m/s, 0-360°, M12 Connector with 5m Cable₹21,759
FirstRate FST200-205A Heated Wind Speed & Direction Sensor, 0-50m/s, 0-360°, RS485, M12 Connector w/ 5m Cable: another version this guide coversFirstRate FST200-205A Heated Wind Speed & Direction Sensor, 0-50m/s, 0-360°, RS485, M12 Connector w/ 5m Cable₹26,729
Mini Ultrasonic Wind Speed and Direction Meter SN-3003-CFSFX-N01 – RS485 Modbus: another version this guide coversMini Ultrasonic Wind Speed and Direction Meter SN-3003-CFSFX-N01 – RS485 Modbus₹10,119
NU200E12TR-1G 12mm 200kHz Ultrasonic Wind Speed Sensor: another version this guide coversNU200E12TR-1G 12mm 200kHz Ultrasonic Wind Speed Sensor₹7,032
NU200E12TR-1T 12mm 200kHz Ultrasonic Wind Speed Sensor – IP68 Stainless Steel: another version this guide coversNU200E12TR-1T 12mm 200kHz Ultrasonic Wind Speed Sensor – IP68 Stainless Steel₹39,689
DFRobot Gravity PAV3015 Air Velocity Sensor (0-15 m/s, I2C) – Module w/ Cable: another version this guide coversDFRobot Gravity PAV3015 Air Velocity Sensor (0-15 m/s, I2C) – Module w/ Cable₹5,379
Generic Anemometer Digital Handheld Wind Speed Meter: another version this guide coversAnemometer Digital Handheld Wind Speed Meter₹884
Fluke 925 ESP Vane Anemometer: another version this guide coversFluke 925 ESP Vane Anemometer₹18,645
HTC AVM-03 Mini Anemometer 0-30m/s with Temperature Range -20.0~60.0ºC: another version this guide coversHTC AVM-03 Mini Anemometer 0-30m/s with Temperature Range -20.0~60.0ºC₹1,509
OWON OWM5500 Smart Anemometer – LCD Display, USB-C Charging: another version this guide coversOWON OWM5500 Smart Anemometer – LCD Display, USB-C Charging₹3,669
UNI-T UT363 Digital Anemometer with Temperature & Backlight LCD – 0-30m/s Wind Speed Meter: another version this guide coversUNI-T UT363 Digital Anemometer with Temperature & Backlight LCD – 0-30m/s Wind Speed Meter₹1,511
UNI-T UT363S Anemometer Wind Speed Meter 0.4~30m/s, Temperature Measurement, Split Sensor, Backlight LCD: another version this guide coversUNI-T UT363S Anemometer Wind Speed Meter 0.4~30m/s, Temperature Measurement, Split Sensor, Backlight LCD₹2,929- Uno R3 development board: the controller used in the wiring tableFind this part
Dupont jumper wires: for the connectionsDupont Jumper Wires (40 pcs)₹49Closest match, check the specs
Solderless breadboard: to build without solderingSolderless Breadboard₹68- USB to RS485 converter: to test Modbus sensors from a PCFind this part
Alternatives and when to choose them
- Weather station sensors: hobby cup and vane sets.
- Rain gauges and solar radiation sensors: the rest of a station.
- Industrial ultrasonic sensors: distance, not wind.
Common mistakes to avoid
- Mounting in wind shadows.
- Wrong pulse factor.
- No debounce on reed outputs.
- Misaligned vane.
Frequently asked questions
How do I convert anemometer pulses to wind speed?
Count pulses per second and multiply by the maker's factor.
Why does my reading seem low?
Buildings or trees block the wind; mount the sensor higher and in the open.
Are ultrasonic anemometers better?
They have no moving parts and measure low speeds well.
Can I read RS485 anemometers with ESP32?
Yes. Use an RS485 module and a Modbus library to read the registers.
How do I align the wind vane?
Turn the vane until its north mark points to true north, then tighten it.
Parts for this guide
- ₹6,339View
- ₹5,809View
FirstRate FST200-201 Wind Speed Anemometer Sensor, 0.5-50 m/s Range, 4-20mA Output, M12 Connector w/ 1.5m Cable₹7,619View
FirstRate FST200-205 Wind Speed & Wind Direction Integrated Sensor, Output 4-20mA, Range 0-50m/s, 0-360°, M12 Connector with 5m Cable₹21,759View
FirstRate FST200-205A Heated Wind Speed & Direction Sensor, 0-50m/s, 0-360°, RS485, M12 Connector w/ 5m Cable₹26,729View- ₹10,119View
- ₹7,032View
- ₹39,689View
- ₹5,379View
- ₹884View
- ₹18,645View
- ₹1,509View
- ₹3,669View
- ₹1,511View
UNI-T UT363S Anemometer Wind Speed Meter 0.4~30m/s, Temperature Measurement, Split Sensor, Backlight LCD₹2,929View- ₹359View
- ₹49View
- ₹68View
- ₹74View
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.