Component guide · Beginner · 3 min read
Humidity Controllers

XH-M452 12V Temperature and Humidity Controller, ZFX-13001 12V Capacitive Humidity Controller and MH13001 Digital Humidity Controller with Probe, 10A
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
These small boards switch a humidifier, fan or dehumidifier on and off to hold a humidity set point, with no coding. They have a display, buttons, a humidity probe and a relay. You set the target, the hysteresis and whether the relay turns on below the set point (humidify) or above it (dehumidify). Typical uses are egg incubators, mushroom and grow boxes and storage cabinets.
Key specs at a glance
- Supply
- 12V DC on all three
- Relay
- Up to 10A contacts; check the module label
- Modes
- Humidify (on below) or dehumidify (on above)
- Hysteresis
- Adjustable on/off gap
- Probe
- Capacitive or SHT-type on a lead
- XH-M452
- Also controls temperature
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1XH-M452 Temperature and Humidity Controller Module, 12V₹435
Option 2ZFX-13001 12V Capacitive Humidity Controller₹1,551
Option 3MH13001 Digital Humidity Controller with Probe, 10A₹271
What the Humidity controller modules: XH-M452, ZFX-13001 and MH13001 with relay outputs is
The XH-M452 and similar humidity controller modules read a humidity sensor and switch a relay to turn a humidifier, dehumidifier or fan on and off at set levels.
Set the mode first, then the set point and a hysteresis of 3-5% RH so the relay does not click constantly. Mount the probe where the air represents the space, not in the mist stream of a humidifier.
Even though the relay is rated for mains, keep 230V wiring in a closed box with a fuse, and use a contactor for heaters or large loads. For logging or remote control, use a microcontroller with a digital sensor instead.
Humidity controller modules: XH-M452, ZFX-13001 and MH13001 with relay outputs pinout
The pins on the Humidity controller modules: XH-M452, ZFX-13001 and MH13001 with relay outputs and what each one does.
| Pin | Function |
|---|---|
| 12V / GND | Supply |
| COM | Relay common |
| NO | Normally open, closes when output is on |
| NC | Normally closed |
| Probe | Humidity probe socket |
- 12V / GND
- Supply
- COM
- Relay common
- NO
- Normally open, closes when output is on
- NC
- Normally closed
- Probe
- Humidity probe socket
Wiring the Humidity controller modules: XH-M452, ZFX-13001 and MH13001 with relay outputs
Disconnect mains before wiring the relay, and keep low-voltage and mains wires apart.
| Humidity controller modules: XH-M452, ZFX-13001 and MH13001 with relay outputs pin | Connection | Note |
|---|---|---|
| 12V | 12V adapter | Polarity marked |
| COM / NO | Humidifier or fan supply | Fused |
| Probe | Probe socket | Keep out of mist |
- 12V
- Connection:
- 12V adapter
- Note:
- Polarity marked
- COM / NO
- Connection:
- Humidifier or fan supply
- Note:
- Fused
- Probe
- Connection:
- Probe socket
- Note:
- Keep out of mist
Example code
Menu keys differ by model; the leaflet with the board lists the button sequence.
1. Power the board from 12V and check it shows humidity.
2. Choose humidify mode (relay ON below set point).
3. Set the target, for example 55% RH for incubation.
4. Set hysteresis to 3-5% RH.
5. Wire the humidifier through COM and NO with a fuse.
6. Watch a full on/off cycle and adjust the hysteresis if it switches too often.Setup and tuning
feed the stated supply (often 12 V DC or 5 V).
plug in the supplied humidity probe and keep it in the space you control.
set humidify or dehumidify mode in the menu.
set the on and off humidity values with a small gap (hysteresis).
switch large or mains loads through a contactor or rated relay inside an enclosure.
What you need
Shop this list3 of 3 found in our store · ₹2,257
XH-M452 Temperature and Humidity Controller Module, 12V: the part this guide coversXH-M452 Temperature and Humidity Controller Module, 12V₹435
ZFX-13001 12V Capacitive Humidity Controller: another version this guide coversZFX-13001 12V Capacitive Humidity Controller₹1,551
MH13001 Digital Humidity Controller with Probe, 10A: another version this guide coversMH13001 Digital Humidity Controller with Probe, 10A₹271
Alternatives and when to choose them
- Analog humidity elements: HR202 relay modules.
- SHT3x humidity sensors: build your own controller.
- Humidity transmitters: for PLC systems.
Common mistakes to avoid
- Switching mains without an enclosure.
- Too small a hysteresis gap.
- Placing the sensor near the humidifier output.
- Exceeding the relay current.
Frequently asked questions
How do I set the XH-M452 to control a humidifier?
Choose humidify mode and set the low and high humidity points.
Can the relay switch mains devices?
Only within its rating and inside a safe enclosure wired by a qualified person.
Why does the relay click on and off often?
The gap between set points is too small; widen it.
Is the humidity reading accurate?
Roughly ±3 to 5 %; check it against a reference.
Can I extend the sensor cable?
Short extensions are fine; long ones can add errors.