Component guide · Intermediate · 5 min read
Analog Humidity Sensors

HR202 and HR202L Elements and Modules, AMT1001, HS1101LF Capacitive, Honeywell HIH-4602 and HIH-5030, Multicomp HCZ Resistive Elements, HS-S10 and HS-S36 Water Vapor Sensors, Asair AHS01IB and DFRobot Steam Sensor
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
Before digital sensors like the SHT3x, humidity was measured with raw elements. Resistive types (HR202, Multicomp HCZ, AMT1001) change resistance with humidity and need AC drive; capacitive HS1101LF changes capacitance and needs a 555 oscillator. Honeywell HIH-4602 and HIH-5030 give a ready voltage proportional to RH. Steam and water vapor sensors detect condensation, not exact RH.
Key specs at a glance
- Resistive
- HR202, HCZ: about 20-90% RH, ±5%, AC drive only
- Capacitive
- HS1101LF: about 180 pF, 1-99% RH
- Voltage output
- HIH-4602, HIH-5030: ratiometric 0.5-2.7V at 3.3V supply
- AMT1001
- Analog RH 0-3V plus thermistor
- Steam sensors
- Analog or I2C, detect water film on the board
- Modules
- HR202 comparator modules give a digital threshold or drive a relay
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1HR 202 Humidity Detection Sensor Module – Digital Output, Adjustable Sensitivity₹45
Option 2HR202 Humidity Sensitive Switch Relay Module – Adjustable Threshold, 250V AC Relay₹197
Option 3HR202L Humidity Sensor with Shell – Analog Output₹23
Option 4HR202L Humidity Sensor without shell – Analog Polymer Sensor₹14
Option 5AMT1001 Resistive Humidity & Temperature Sensor Module – Analog Output₹197
Option 6HS1101LF Humidity Sensor – Capacitive RH Sensor, 1-99% RH, -60°C to 140°C₹369
What the Analog humidity elements: HR202, AMT1001, HS1101LF, Honeywell HIH, Multicomp HCZ and steam sensors is
These are raw humidity sensing parts: resistive and capacitive elements that change with moisture, and voltage-output sensors that give a ready analog humidity signal.
For a new project, a digital SHT3x or AHT20 is simpler and more accurate. Use these elements when repairing existing equipment, in teaching labs, or for HIH sensors where a plain analog voltage suits a PLC or ADC.
Never put DC through a resistive element; it polarises and drifts. The HR202 modules handle this. HIH sensors need temperature correction: true RH = sensor RH / (1.0546 - 0.00216 × T). The comparator modules only switch at a set level, they do not measure.
Analog humidity elements: HR202, AMT1001, HS1101LF, Honeywell HIH, Multicomp HCZ and steam sensors pinout
The pins on the Analog humidity elements: HR202, AMT1001, HS1101LF, Honeywell HIH, Multicomp HCZ and steam sensors and what each one does.
| Pin | Function |
|---|---|
| VCC | 3.3 or 5V (modules, HIH) |
| GND | Ground |
| AO / Vout | Analog output |
| DO | Threshold output on comparator modules |
| Element leads | Two pins on bare HR202, HS1101, HCZ |
- VCC
- 3.3 or 5V (modules, HIH)
- GND
- Ground
- AO / Vout
- Analog output
- DO
- Threshold output on comparator modules
- Element leads
- Two pins on bare HR202, HS1101, HCZ
Wiring the Analog humidity elements: HR202, AMT1001, HS1101LF, Honeywell HIH, Multicomp HCZ and steam sensors
Keep sensors out of direct sun and away from heat sources on the board.
| Analog humidity elements: HR202, AMT1001, HS1101LF, Honeywell HIH, Multicomp HCZ and steam sensors pin | Arduino | Note |
|---|---|---|
| HIH-5030 Vout | A0 | Supply 3.3V, ratiometric |
| HR202 module AO | A1 | Inverse: higher RH, lower voltage |
| HR202 module DO | D2 | Set threshold with the pot |
- HIH-5030 Vout
- Arduino:
- A0
- Note:
- Supply 3.3V, ratiometric
- HR202 module AO
- Arduino:
- A1
- Note:
- Inverse: higher RH, lower voltage
- HR202 module DO
- Arduino:
- D2
- Note:
- Set threshold with the pot
Example code
HIH-5030 is rated at 2.7-5.5V; the formula is ratiometric so use the real supply voltage.
const float VS = 5.0; // supply voltage used for the HIH
const float tempC = 25.0; // use a real temperature sensor here
void setup() { Serial.begin(9600); }
void loop() {
float v = analogRead(A0) * VS / 1023.0;
float rhSensor = (v / VS - 0.1515) / 0.00636; // HIH datasheet line
float rhTrue = rhSensor / (1.0546 - 0.00216 * tempC); // temperature correction
Serial.print("RH "); Serial.print(rhTrue, 1); Serial.println(" %");
delay(1000);
}Setup and tuning
drive HR202 and HCZ elements with an AC signal or alternating pins; DC slowly damages them.
put the HS1101LF in a 555 circuit and measure the frequency, which falls as humidity rises.
read HIH-4602 or HIH-5030 with analogRead and use the datasheet formula with your supply voltage.
humidity readings depend on temperature, so measure temperature too and apply the datasheet correction.
HR202 modules with a pot only give a wet or dry output. Use them for thresholds, not measurements.
What you need
Shop this list18 of 19 found in our store · ₹12,877
Generic HR 202 Humidity Detection Sensor Module – Digital Output, Adjustable Sensitivity: the part this guide coversHR 202 Humidity Detection Sensor Module – Digital Output, Adjustable Sensitivity₹45
Generic HR202 Humidity Sensitive Switch Relay Module – Adjustable Threshold, 250V AC Relay: another version this guide coversHR202 Humidity Sensitive Switch Relay Module – Adjustable Threshold, 250V AC Relay₹197
HR202L Humidity Sensor with Shell – Analog Output: another version this guide coversHR202L Humidity Sensor with Shell – Analog Output₹23
HR202L Humidity Sensor without shell – Analog Polymer Sensor: another version this guide coversHR202L Humidity Sensor without shell – Analog Polymer Sensor₹14
AMT1001 Resistive Humidity & Temperature Sensor Module – Analog Output: another version this guide coversAMT1001 Resistive Humidity & Temperature Sensor Module – Analog Output₹197
HS1101LF Humidity Sensor – Capacitive RH Sensor, 1-99% RH, -60°C to 140°C: another version this guide coversHS1101LF Humidity Sensor – Capacitive RH Sensor, 1-99% RH, -60°C to 140°C₹369
Honeywell HIH 4602 Humidity Sensor, 0% to 100% RH, Analog Output, Through Hole: another version this guide coversHoneywell HIH 4602 Humidity Sensor, 0% to 100% RH, Analog Output, Through Hole₹8,919
Honeywell HIH-5030-001 Humidity Sensor, 0-100% RH, Analog Output, SMD/SMT: another version this guide coversHoneywell HIH-5030-001 Humidity Sensor, 0-100% RH, Analog Output, SMD/SMT₹1,199
Multicomp Pro HCZ Series Humidity Sensor, 20% to 90% RH, ±5% Accuracy, Through Hole Enclosed: another version this guide coversMulticomp Pro HCZ Series Humidity Sensor, 20% to 90% RH, ±5% Accuracy, Through Hole Enclosed₹149
Multicomp Pro Humidity Sensor, 20% to 90% RH, 3% Accuracy, 1V Supply, Through Hole: another version this guide coversMulticomp Pro Humidity Sensor, 20% to 90% RH, 3% Accuracy, 1V Supply, Through Hole₹309
Multicomp Pro Humidity Sensor, 20% to 90% RH, 5% Accuracy, 1V, Through Hole: another version this guide coversMulticomp Pro Humidity Sensor, 20% to 90% RH, 5% Accuracy, 1V, Through Hole₹249
HS-S10A Water Vapor Sensor – 5V DC, Plastic Housing: another version this guide coversHS-S10A Water Vapor Sensor – 5V DC, Plastic Housing₹68
HS-S10P Water Vapor Sensor Module – High-Precision Humidity Detection: another version this guide coversHS-S10P Water Vapor Sensor Module – High-Precision Humidity Detection₹90
HS-S36-L Water Vapor Sensor – 5V DC, High-Precision Humidity Detection: another version this guide coversHS-S36-L Water Vapor Sensor – 5V DC, High-Precision Humidity Detection₹88
Asair AHS01IB Steam Sensor Module – I2C Digital Interface: another version this guide coversAsair AHS01IB Steam Sensor Module – I2C Digital Interface₹669
DFRobot Gravity Steam Sensor – Analog Output Module: another version this guide coversDFRobot Gravity Steam Sensor – Analog Output Module₹175- Uno R3 development board: the controller used in the wiring tableFind this part
Dupont jumper wires: for the connectionsDupont Jumper Wires (40 pcs)₹49Closest match, check the specs
Solderless breadboard: to build without solderingSolderless Breadboard₹68
Alternatives and when to choose them
- SHT3x humidity sensors: accurate digital choice.
- AHT20 humidity sensor: cheap digital choice.
- Humidity transmitters: 4-20 mA for industry.
Common mistakes to avoid
- Driving a resistive element with steady DC.
- Ignoring temperature correction on voltage-output sensors.
- Using a wet/dry comparator module to measure humidity percentage.
- Using the 5 V formula with a 3.3 V supply on ratiometric sensors.
Frequently asked questions
Can I connect an HR202 element straight to analogRead?
Not with steady DC. It needs AC drive, so use a module with an oscillator or switch the pins in software.
How accurate are these elements?
Resistive elements are about ±5% RH, while the Honeywell HIH sensors are about ±3.5% RH when corrected for temperature.
Why use an analog humidity sensor today?
They suit simple threshold circuits, legacy designs and teaching; digital sensors like the SHT31 are easier for new projects.
What does a steam sensor detect?
It detects water film or droplets on the board, not percent humidity, so it suits condensation alarms.
How do I read the HS1101LF with an Arduino?
Use it in a 555 oscillator and measure the frequency with pulseIn or a frequency counter library.
Parts for this guide
Projects that use it
Put this into practice: 1 step-by-step build in our project library uses parts from this guide.
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.