The MQ-135 is a heated gas sensor that responds to ammonia, benzene, alcohol, smoke and other pollutants, so its analog output works as a general indoor air quality indicator. It needs 5 V, about 150 mA and a warm-up period. It is not a real CO2 sensor: for accurate CO2 use an NDIR sensor such as the MH-Z19 or SCD40.
Key specs at a glance
- Detects
- NH3, NOx, alcohol, benzene, smoke, CO2 (weak response)
- Range
- About 10 to 1000 ppm for ammonia and benzene (needs calibration)
- Heater
- 5 V, about 150 mA
- Outputs
- AO analog, DO digital with trimmer threshold
- Warm-up
- Minutes for use, 24 to 48 hours burn-in for new sensors
- Supply
- 5 V
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1MQ-135 Air Quality & Gas Detector Sensor Module for Arduino – Analog & TTL Output₹114
Option 2MQ-135 Air Quality Sensor Harmful Gas Detection Module – Analog & Digital Output₹114
Option 3Waveshare MQ-135 Air Quality Gas Sensor Module – Analog/Digital Output₹459
Option 4Winsen MQ135 Semiconductor Air Quality Sensor – SnO2 Gas Detection Module₹239
What the MQ-135 air quality sensor is
Like the MQ-2, the MQ-135 is a heated tin dioxide sensor whose resistance drops in the presence of certain gases. Its material is tuned toward air pollutants, which makes it a popular cheap air quality indicator for classrooms and kitchens.
Many tutorials print a CO2 ppm number from it. That number is an estimate based on assumptions; the sensor reacts much more strongly to other gases, so use it as an index, not a measurement.
MQ-135 air quality sensor pinout
The pins on the MQ-135 air quality sensor and what each one does.
| Pin | Function |
|---|---|
| VCC | 5 V |
| GND | Ground |
| AO | Analog output, higher = more pollutants |
| DO | Digital alarm output (trimmer threshold) |
- VCC
- 5 V
- GND
- Ground
- AO
- Analog output, higher = more pollutants
- DO
- Digital alarm output (trimmer threshold)
Wiring the MQ-135 air quality sensor
Scale AO with a divider before an ESP32 pin. Keep the sensor away from the board's regulator so its heat does not affect other sensors.
| MQ-135 air quality sensor pin | Arduino Uno | ESP32 |
|---|---|---|
| VCC | 5V | 5V (VIN) |
| GND | GND | GND |
| AO | A0 | GPIO 34 via 10k/20k divider |
| DO | D2 | GPIO 27 |
- VCC
- Arduino Uno:
- 5V
- ESP32:
- 5V (VIN)
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- AO
- Arduino Uno:
- A0
- ESP32:
- GPIO 34 via 10k/20k divider
- DO
- Arduino Uno:
- D2
- ESP32:
- GPIO 27
Example code
The thresholds are examples. Record values in fresh outdoor air and in your room to set your own levels.
const int AO_PIN = A0;
float avg = 0;
void setup() {
Serial.begin(9600);
delay(120000); // 2 minute warm-up
avg = analogRead(AO_PIN);
}
void loop() {
avg = avg * 0.9 + analogRead(AO_PIN) * 0.1; // smooth the reading
const char* level = avg < 200 ? "good" : avg < 350 ? "moderate" : "poor";
Serial.print((int)avg); Serial.print(" "); Serial.println(level);
delay(1000);
}Setup and tuning
after burn-in, note the reading outdoors or by an open window. Compare indoor values against it.
change the reading; pair it with an AHT20 if you want to compensate.
(MQ135 library) use a reference resistance R0 that you must calibrate; without it the numbers are not meaningful.
a rising trend over an hour is a good trigger to open a window.
What you need
Shop this list6 of 6 found in our store · ₹1,454
MQ-135 air quality and gas detector module: the common moduleMQ-135 Air Quality & Gas Detector Sensor Module for Arduino – Analog & TTL Output₹114
MQ-135 harmful gas detection module: alternative boardMQ-135 Air Quality Sensor Harmful Gas Detection Module – Analog & Digital Output₹114
Waveshare MQ-135 air quality gas sensor: Waveshare boardWaveshare MQ-135 Air Quality Gas Sensor Module – Analog/Digital Output₹459
Winsen MQ135 air quality sensor: the original maker's sensorWinsen MQ135 Semiconductor Air Quality Sensor – SnO2 Gas Detection Module₹239
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389
0.96 inch OLED display 128x64: to show readings without a computer0.96" OLED Display 128x64₹139Closest match, check the specs
Alternatives and when to choose them
- CO2 NDIR sensors: MH-Z19, SCD40 for real CO2 ppm.
- VOC sensors: SGP30, ENS160 with digital output.
- PM2.5 dust sensors: for smoke and dust particles.
Try it: Voltage divider calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Treating its output as accurate CO2 ppm.
- Reading before warm-up.
- Powering the heater from a 3.3 V pin.
- Mounting it inside a closed box with the controller.
Frequently asked questions
Can the MQ-135 measure CO2?
Only roughly. It responds more strongly to other gases; use an NDIR sensor for real CO2 values.
What does a higher reading mean?
More pollutants such as ammonia, alcohol, smoke or benzene in the air.
How long is the warm-up?
A few minutes for use; a new sensor needs 24 to 48 hours of burn-in.
Does it work with ESP32?
Yes, powered from 5 V with the analog output scaled to 3.3 V.
MQ-135 or MQ-2?
MQ-135 for air quality, MQ-2 for flammable gas and smoke.
Why does the reading drift?
Temperature, humidity and sensor ageing. Re-check the clean-air baseline regularly.