The MQ-7 is a metal-oxide sensor for carbon monoxide (CO) from 20 to 2,000 ppm. The datasheet runs its heater in a cycle, 60 s at 5 V then 90 s at 1.4 V, and reads at the end of the low phase. Most modules keep the heater at 5 V, which shows trends but not accurate ppm. Use it for learning projects, not as a safety alarm.
Key specs at a glance
- Detects
- Carbon Monoxide
- Range
- About 20 to 2,000 ppm CO
- Heater
- 5 V, about 150 mA (about 0.75 W)
- Output
- Analog (AO) and digital threshold (DO) on modules
- Warm-up
- A few minutes before use; 24 to 48 hours of burn-in for stable readings
- Heater cycle
- Datasheet method: 5 V for 60 s, then 1.4 V for 90 s, read at the end of the low phase
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
What the MQ-7 is
The MQ-7 detects carbon monoxide (CO), the poisonous gas from incomplete burning. It is meant to run with a two-step heater cycle: a hot phase at 5 V cleans the sensing layer, and CO is measured during a cooler phase at 1.4 V.
Most low-cost modules power the heater from a constant 5 V, so they show changes in CO but are less accurate than the datasheet method. MQ sensors are for hobby and learning projects. They are not certified gas alarms; for safety use an approved detector.
MQ-7 pinout
The pins on the MQ-7 and what each one does.
| Pin | Function |
|---|---|
| VCC | 5 V supply for the heater and the comparator |
| GND | Ground |
| AO | Analog output: rises as the gas level rises |
| DO | Digital output from the LM393 comparator; switches at the level set by the trim pot |
- VCC
- 5 V supply for the heater and the comparator
- GND
- Ground
- AO
- Analog output: rises as the gas level rises
- DO
- Digital output from the LM393 comparator; switches at the level set by the trim pot
Wiring the MQ-7
The heater draws about 150 mA, so power it from the 5 V rail, not a 3.3 V pin. The analog output can reach 5 V, so an ESP32 needs a divider (10 kΩ over 20 kΩ gives a third off) on AO.
| MQ-7 pin | Arduino Uno | ESP32 |
|---|---|---|
| VCC | 5V | 5V (VIN) |
| GND | GND | GND |
| AO | A0 | GPIO 34 through a 10k/20k divider |
| DO | D2 (optional) | GPIO 27 (optional, via divider) |
- VCC
- Arduino Uno:
- 5V
- ESP32:
- 5V (VIN)
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- AO
- Arduino Uno:
- A0
- ESP32:
- GPIO 34 through a 10k/20k divider
- DO
- Arduino Uno:
- D2 (optional)
- ESP32:
- GPIO 27 (optional, via divider)
Example code
Rs/R0 falls as the gas level rises. Convert it to ppm with the curve in the datasheet; treat the result as an estimate, not a certified reading.
const int AO = A0;
const float RL = 10.0; // load resistor on the module, kOhm (check yours)
const float CLEAN_AIR = 27.5; // Rs/R0 in clean air from the datasheet curve
float R0 = 0;
float readRs() {
long sum = 0;
for (int i = 0; i < 50; i++) { sum += analogRead(AO); delay(5); }
float v = (sum / 50.0) * 5.0 / 1023.0;
return RL * (5.0 - v) / v; // sensor resistance, kOhm
}
void setup() {
Serial.begin(115200);
Serial.println("Warming up 3 minutes in clean air...");
delay(180000);
R0 = readRs() / CLEAN_AIR; // calibrate in clean air
Serial.print("R0 = "); Serial.println(R0);
}
void loop() {
float ratio = readRs() / R0; // lower ratio = more gas
Serial.print("Rs/R0 = "); Serial.println(ratio, 2);
delay(1000);
}Setup and tuning
for better readings, switch the heater with a logic-level MOSFET and PWM it to about 1.4 V average for 90 s after each 60 s at 5 V; read just before the hot phase starts.
R0 in clean outdoor air.
CO mixes with air, so mount it at breathing height.
What you need
Shop this list4 of 6 found in our store · ₹671
MQ-7 carbon monoxide gas sensor module: the sensor this guide coversMQ-7 CO Carbon Monoxide Gas Sensor Module – Analog & Digital Output₹116Closest match, check the specs
Waveshare MQ-7 Carbon Monoxide Sensor Module – 20-2000ppm CO Detection: another version this guide coversWaveshare MQ-7 Carbon Monoxide Sensor Module – 20-2000ppm CO Detection₹479- Uno R3 development board: the controller used in the wiring tableFind this part
- IRLZ44N logic-level MOSFET: to cycle the heater as the datasheet asksFind this part
Buzzer module 3.3-5 V: for an audible alarmBuzzer Module 3.3–5V₹27
Dupont jumper wires: for the connectionsDupont Jumper Wires (40 pcs)₹49Closest match, check the specs
Alternatives and when to choose them
- MQ-9: CO plus combustible gases.
- Electrochemical gas sensors: accurate, selective CO measurement.
- MQ gas sensors: the family compared.
Try it: Voltage divider calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Running the heater at a constant 5 V and expecting datasheet accuracy.
- Using it as a life-safety CO alarm.
- Calibrating R0 indoors near a stove.
- Testing with car exhaust in a closed space.
Frequently asked questions
What does the MQ-7 detect?
Carbon monoxide, with some response to hydrogen.
Why does the MQ-7 need a heater cycle?
The hot phase cleans the sensor and the low phase gives the CO reading; it is how the datasheet calibrates it.
Can I use it without cycling?
Yes for rough trends, but readings are less accurate.
Is it a CO alarm?
No. Use a certified CO alarm for safety.
Does it work on 3.3 V boards?
The heater needs 5 V; divide the analog output for 3.3 V ADCs.