Component guide · Beginner · 3 min read
MQ-9 CO and Combustible Gas Sensor

Pinout, Wiring and Code
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
The MQ-9 is a metal-oxide gas sensor for carbon monoxide and combustible gases such as methane and LPG. It is designed to cycle its heater between 5 V and 1.5 V, reading gases in the hot phase and CO in the cool phase. Modules give analog and digital outputs. Power it from 5 V and use it for learning, not as a safety alarm.
Key specs at a glance
- Detects
- CO and Combustible Gas
- Range
- CO about 10 to 1,000 ppm (low-heat phase); methane and LPG about 100 to 10,000 ppm (high-heat phase)
- Heater
- 5 V, about 150 mA (about 0.75 W)
- Output
- Analog (AO) and digital threshold (DO) on modules
- Warm-up
- A few minutes before use; 24 to 48 hours of burn-in for stable readings
- Heater cycle
- Datasheet method: 5 V for 60 s (combustible gases), 1.5 V for 90 s (CO)
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
What the MQ-9 is
The MQ-9 detects carbon monoxide and combustible gases such as methane and LPG. Like the MQ-7, it is designed for a heater cycle: the high phase measures combustible gases and cleans the sensor, and the low phase measures CO.
Modules with a constant 5 V heater mainly show combustible gas changes. MQ sensors are for hobby and learning projects. They are not certified gas alarms; for safety use an approved detector.
MQ-9 pinout
The pins on the MQ-9 and what each one does.
| Pin | Function |
|---|---|
| VCC | 5 V supply for the heater and the comparator |
| GND | Ground |
| AO | Analog output: rises as the gas level rises |
| DO | Digital output from the LM393 comparator; switches at the level set by the trim pot |
- VCC
- 5 V supply for the heater and the comparator
- GND
- Ground
- AO
- Analog output: rises as the gas level rises
- DO
- Digital output from the LM393 comparator; switches at the level set by the trim pot
Wiring the MQ-9
The heater draws about 150 mA, so power it from the 5 V rail, not a 3.3 V pin. The analog output can reach 5 V, so an ESP32 needs a divider (10 kΩ over 20 kΩ gives a third off) on AO.
| MQ-9 pin | Arduino Uno | ESP32 |
|---|---|---|
| VCC | 5V | 5V (VIN) |
| GND | GND | GND |
| AO | A0 | GPIO 34 through a 10k/20k divider |
| DO | D2 (optional) | GPIO 27 (optional, via divider) |
- VCC
- Arduino Uno:
- 5V
- ESP32:
- 5V (VIN)
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- AO
- Arduino Uno:
- A0
- ESP32:
- GPIO 34 through a 10k/20k divider
- DO
- Arduino Uno:
- D2 (optional)
- ESP32:
- GPIO 27 (optional, via divider)
Example code
Rs/R0 falls as the gas level rises. Convert it to ppm with the curve in the datasheet; treat the result as an estimate, not a certified reading.
const int AO = A0;
const float RL = 10.0; // load resistor on the module, kOhm (check yours)
const float CLEAN_AIR = 9.6; // Rs/R0 in clean air from the datasheet curve
float R0 = 0;
float readRs() {
long sum = 0;
for (int i = 0; i < 50; i++) { sum += analogRead(AO); delay(5); }
float v = (sum / 50.0) * 5.0 / 1023.0;
return RL * (5.0 - v) / v; // sensor resistance, kOhm
}
void setup() {
Serial.begin(115200);
Serial.println("Warming up 3 minutes in clean air...");
delay(180000);
R0 = readRs() / CLEAN_AIR; // calibrate in clean air
Serial.print("R0 = "); Serial.println(R0);
}
void loop() {
float ratio = readRs() / R0; // lower ratio = more gas
Serial.print("Rs/R0 = "); Serial.println(ratio, 2);
delay(1000);
}Setup and tuning
read combustible gases at the end of the 5 V phase and CO at the end of the 1.5 V phase.
set R0 in clean air (clean-air ratio about 9.6).
for 24 to 48 hours when new.
record readings over a day to see the normal range before setting an alarm level.
What you need
Shop this list6 of 7 found in our store · ₹2,667
MQ-9 CO, methane and LPG gas sensor module: the sensor this guide coversMQ-9 CO, Methane & LPG Gas Sensor Module – 5V DC, Analog & Digital Output₹119Closest match, check the specs
DFRobot Gravity Analog CO/Combustible Gas Sensor MQ9 Module: another version this guide coversDFRobot Gravity Analog CO/Combustible Gas Sensor MQ9 Module₹1,019
Seeed Studio Studio Grove MQ9 Gas Sensor Module for CO & Combustible Gas Detection – Analog Output: another version this guide coversSeeed Studio Grove MQ9 Gas Sensor Module for CO & Combustible Gas Detection – Analog Output₹1,259Closest match, check the specs- Uno R3 development board: the controller used in the wiring tableFind this part
IRLZ44N logic-level MOSFET: to cycle the heaterIRLZ44N Logic-Level N-Channel MOSFET₹42Closest match, check the specs
16x2 LCD with I2C: to show readings on a character display16×2 LCD with I2C (RG1602A)₹179Closest match, check the specs
Dupont jumper wires: for the connectionsDupont Jumper Wires (40 pcs)₹49Closest match, check the specs
Alternatives and when to choose them
- MQ-7: focused on CO.
- MQ-5: focused on LPG.
- MQ gas sensors: the family compared.
Try it: Voltage divider calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Expecting CO readings with the heater at a constant 5 V.
- Using it as a certified safety detector.
- Not burning in a new sensor.
- Comparing readings from different modules without calibrating each.
Frequently asked questions
What does the MQ-9 detect?
Carbon monoxide in its low-heat phase and methane, LPG and other combustible gases in its high-heat phase.
Do I need the heater cycle?
For CO readings, yes; for combustible gas trends a constant 5 V works.
Is the MQ-9 better than the MQ-7?
It covers more gases; the MQ-7 is more focused on CO.
Can it power from 3.3 V?
No, the heater needs 5 V.
How do I get ppm?
From the datasheet curves using Rs/R0; treat results as estimates.