Component guide · Intermediate · 4 min read
Oxygen Sensors

Galvanic Cells (Asair AO-02 to AO-09, Winsen ME2-O2, MED-O2), Ultrasonic and Fluorescent O2 Modules
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
Oxygen sensors come in three types. Galvanic cells (Asair AO series, Winsen ME2-O2, MED-O2) make a small voltage, about 9 to 13 mV in normal air, and need an amplifier or 16-bit ADC. Ultrasonic modules (AOF1010, US1000, Gasboard-7500HA) measure 0 to 100 percent O2 in concentrators over UART. Fluorescent sensors (AOX4000) last much longer and need no consumable cell.
Key specs at a glance
- Range
- 0 to 25% (ambient) or 0 to 100% (medical, concentrators)
- Galvanic output
- About 9 to 13 mV in air (20.9% O2)
- Ultrasonic
- UART, also gives flow and temperature
- Accuracy
- About plus or minus 1 to 2% O2 typical
- Galvanic life
- About 1 to 2 years (lead-free AOX3000 longer)
- Use
- Confined spaces, incubators, oxygen concentrators
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Asair AO-02 Oxygen Sensor – Electrochemical Partial Pressure Sensor₹1,839
Option 2Asair AO-03 Oxygen Sensor Module – 1-25% Vol. Linear Output₹1,219
Option 3Asair AO-07 Oxygen Sensor Module – 0-100% Vol. O2, 9-13mV Output₹2,599
Option 4Asair AO-09 Oxygen Sensor Module – Medical Grade, 0-100% O2₹2,519
Option 5Asair AOX3000 Lead-free Oxygen Sensor – Industrial Fuel Cell Design₹2,219
Option 6Winsen ME2-O2-Ф20 Oxygen Gas Sensor Module – 0-25%Vol Electrochemical₹3,389
What the Oxygen (O2) sensors is
Oxygen (O2) sensors such as the DFRobot Gravity O2, Winsen ME2-O2 and SGX electrochemical cells measure oxygen level in air, for incubators, safety monitors and grow rooms.
Galvanic cells need no power and drift slowly: calibrate in fresh air as 20.9 percent and the output is proportional from there.
Ultrasonic sensors need a flow of oxygen-air mix through them, so they suit concentrators rather than room monitoring.
Oxygen (O2) sensors pinout
The pins on the Oxygen (O2) sensors and what each one does.
| Pin | Function |
|---|---|
| Galvanic + | Amplifier or ADC + |
| Galvanic - | Ground |
| UART modules | VCC, GND, TX, RX |
- Galvanic +
- Amplifier or ADC +
- Galvanic -
- Ground
- UART modules
- VCC, GND, TX, RX
Wiring the Oxygen (O2) sensors
Use the ADS1115 at gain 16 (plus or minus 0.256 V range) for the best resolution on a 10 mV signal.
| Oxygen (O2) sensors pin | Arduino Uno | ESP32 |
|---|---|---|
| Cell + | ADS1115 A0 | ADS1115 A0 |
| Cell - | ADS1115 A1 (differential) or GND | Same |
| ADS1115 SDA / SCL | A4 / A5 | GPIO 21 / 22 |
| ADS1115 VDD | 5 V | 3.3 V |
- Cell +
- Arduino Uno:
- ADS1115 A0
- ESP32:
- ADS1115 A0
- Cell -
- Arduino Uno:
- ADS1115 A1 (differential) or GND
- ESP32:
- Same
- ADS1115 SDA / SCL
- Arduino Uno:
- A4 / A5
- ESP32:
- GPIO 21 / 22
- ADS1115 VDD
- Arduino Uno:
- 5 V
- ESP32:
- 3.3 V
Example code
A minimal sketch to check the part works.
#include <Adafruit_ADS1X15.h>
Adafruit_ADS1115 ads;
float airMv;
float mv() { return ads.computeVolts(ads.readADC_Differential_0_1()) * 1000.0; }
void setup() {
Serial.begin(115200);
ads.begin(); ads.setGain(GAIN_SIXTEEN);
delay(5000);
airMv = mv(); // calibrate in fresh air
}
void loop() {
float o2 = mv() / airMv * 20.9;
Serial.print(o2, 1); Serial.println(" % O2");
delay(1000);
}Setup and tuning
most are electrochemical cells with a 1 to 2 year life; galvanic cells need no power.
Gravity boards use I2C or analog at 3.3 to 5 V; bare cells give microamps that need an amplifier.
calibrate in fresh air at 20.9 % O2 after installation.
allow a few minutes after power-up before reading.
keep the cell away from direct airflow, solvents and condensation.
What you need
Shop this list15 of 16 found in our store · ₹32,813
Asair AO-02 Oxygen Sensor – Electrochemical Partial Pressure Sensor: the part this guide coversAsair AO-02 Oxygen Sensor – Electrochemical Partial Pressure Sensor₹1,839
Asair AO-03 Oxygen Sensor Module – 1-25% Vol. Linear Output: another version this guide coversAsair AO-03 Oxygen Sensor Module – 1-25% Vol. Linear Output₹1,219
Asair AO-07 Oxygen Sensor Module – 0-100% Vol. O2, 9-13mV Output: another version this guide coversAsair AO-07 Oxygen Sensor Module – 0-100% Vol. O2, 9-13mV Output₹2,599
Asair AO-09 Oxygen Sensor Module – Medical Grade, 0-100% O2: another version this guide coversAsair AO-09 Oxygen Sensor Module – Medical Grade, 0-100% O2₹2,519
Asair AOX3000 Lead-free Oxygen Sensor – Industrial Fuel Cell Design: another version this guide coversAsair AOX3000 Lead-free Oxygen Sensor – Industrial Fuel Cell Design₹2,219
Winsen ME2-O2-Ф20 Oxygen Gas Sensor Module – 0-25%Vol Electrochemical: another version this guide coversWinsen ME2-O2-Ф20 Oxygen Gas Sensor Module – 0-25%Vol Electrochemical₹3,389
Winsen MED-O2-LA Oxygen Gas Sensor – Fuel Cell Electrochemical Sensor: another version this guide coversWinsen MED-O2-LA Oxygen Gas Sensor – Fuel Cell Electrochemical Sensor₹2,769
Asair AOF1010 Ultrasonic Oxygen Sensor – UART/9600bps: another version this guide coversAsair AOF1010 Ultrasonic Oxygen Sensor – UART/9600bps₹929
Winsen US1000 Ultrasonic Oxygen Sensor – UART Output: another version this guide coversWinsen US1000 Ultrasonic Oxygen Sensor – UART Output₹1,919
Cubic Sensor Gasboard-7500HA Ultrasonic Oxygen Sensor Module (0-100% O₂, 0-10L/min) – UART TTL & Analog Output: another version this guide coversCubic Sensor Gasboard-7500HA Ultrasonic Oxygen Sensor Module (0-100% O₂, 0-10L/min) – UART TTL & Analog Output₹9,919
Asair AOX4000 Fluorescent Oxygen Sensor Module – Digital Output, Temperature Compensated: another version this guide coversAsair AOX4000 Fluorescent Oxygen Sensor Module – Digital Output, Temperature Compensated₹2,739
ADS1115 16-bit 4-channel ADC module: to read small sensor voltages accuratelyADS1115 16-Bit 4-Channel ADC Module₹199
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389- Uno R3 development board: the controller used in the wiring tableFind this part
Buzzer module 3.3-5 V: for an audible alarmBuzzer Module 3.3–5V₹27
0.96 inch OLED display 128x64: to show readings without a computer0.96" OLED Display 128x64₹139Closest match, check the specs
Alternatives and when to choose them
- DFRobot Gravity O2 boards: ready I2C output.
- Electrochemical gas sensors: related cells.
- Winsen ME3 and ME4: toxic gas cells.
Common mistakes to avoid
- Calibrating in a closed room with low oxygen.
- Using an old cell past its life.
- Exposing the cell to solvents.
- Using it as a medical oxygen monitor.
Frequently asked questions
What oxygen level is normal in air?
Fresh air contains about 20.9 % oxygen; below 19.5 % is considered unsafe.
How long does an oxygen sensor last?
Electrochemical cells usually last 1 to 2 years, then the reading drops and the cell must be replaced.
How do I calibrate the O2 sensor?
Place it in fresh outdoor air and set the reading to 20.9 %.
Can I read it with Arduino?
Yes. The DFRobot Gravity O2 sensor uses I2C with a ready library.
Can it be used for medical oxygen?
Not as a medical device; certified analysers are required for patients.