Component guide · Advanced · 4 min read
Electrochemical Gas Cells

Winsen ME3, ME4, MED, ME2-CO, Asair ACM3000 / AHS3000 and Figaro TGS5042 / TGS5141
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
These are bare electrochemical gas cells: CO, H2S, NH3, NO2, SO2, O3, HF, HCl and H2. Each makes a tiny current proportional to the gas, measured in nanoamps per ppm. Three-electrode ME3 and ME4 cells need a potentiostat circuit such as one built around an LMP91000-style chip, while two-electrode CO cells such as the TGS5042 can be read with a simple op-amp.
Key specs at a glance
- Output
- Current, about 10 to 100 nA per ppm by gas
- Electrodes
- 3 (ME3, ME4, MED) or 2 (TGS5042, TGS5141, ME2-CO)
- Ranges
- e.g. CO 0 to 1000 ppm, NH3 0 to 50 ppm, NO2 0 to 20 ppm
- Response
- T90 under 30 to 60 s
- Life
- About 2 years in air
- Power
- Almost zero; ideal for battery alarms
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Winsen ME3-CO Electrochemical Carbon Monoxide Sensor – 0-1000ppm Range₹1,499
Option 2Winsen ME3-H2S Hydrogen Sulfide Sensor – Electrochemical Gas Sensor₹953
Option 3Winsen ME3-NH3 Electrochemical Ammonia Sensor – 0-50 ppm Range₹6,279
Option 4Winsen ME3-NO2 Electrochemical Nitrogen Dioxide Gas Sensor – 0-20ppm Range₹6,759
Option 5Winsen ME3-SO2 Electrochemical SO2 Gas Sensor – 0-20ppm Range₹9,869
Option 6Winsen ME3-HF Electrochemical Hydrogen Fluoride Sensor – 0-10ppm Range₹8,639
What the Winsen ME3, ME4 and MED electrochemical cells is
Winsen ME3 and ME4 electrochemical gas sensors measure gases like CO, H2S, NH3, O2 and NO2 with good selectivity, giving a small current proportional to concentration.
Keep the working and reference electrodes shorted when the cell is unpowered; most boards use a JFET to do this. Without it, the cell takes hours to settle after power-up.
If you need ppm without analog design work, use the matching ZE module or the Figaro CMM5042 module, which already contain the circuit.
Winsen ME3, ME4 and MED electrochemical cells pinout
The pins on the Winsen ME3, ME4 and MED electrochemical cells and what each one does.
| Pin | Function |
|---|---|
| WE | Working electrode |
| RE | Reference electrode |
| CE | Counter electrode |
| Two-pin cells | + and - |
- WE
- Working electrode
- RE
- Reference electrode
- CE
- Counter electrode
- Two-pin cells
- + and -
Wiring the Winsen ME3, ME4 and MED electrochemical cells
Each gas has its own bias voltage (0 mV for CO and H2S, a set bias for NH3 on some cells). Copy it from the cell's datasheet.
| Winsen ME3, ME4 and MED electrochemical cells pin | Arduino Uno | ESP32 |
|---|---|---|
| Cell | Potentiostat or op-amp board | Potentiostat or op-amp board |
| Board output | ADS1115 A0 | ADS1115 A0 |
| ADS1115 SDA / SCL | A4 / A5 | GPIO 21 / 22 |
| Supply | 3.3 to 5 V | 3.3 V |
- Cell
- Arduino Uno:
- Potentiostat or op-amp board
- ESP32:
- Potentiostat or op-amp board
- Board output
- Arduino Uno:
- ADS1115 A0
- ESP32:
- ADS1115 A0
- ADS1115 SDA / SCL
- Arduino Uno:
- A4 / A5
- ESP32:
- GPIO 21 / 22
- Supply
- Arduino Uno:
- 3.3 to 5 V
- ESP32:
- 3.3 V
Example code
A minimal sketch to check the part works.
#include <Adafruit_ADS1X15.h>
Adafruit_ADS1115 ads;
const float GAIN_V_PER_NA = 0.001; // your transimpedance: e.g. 1 M ohm = 1 mV per nA
const float NA_PER_PPM = 70.0; // sensitivity from the cell's test sheet
float zeroV = 0;
void setup() {
Serial.begin(115200);
ads.begin(); ads.setGain(GAIN_ONE);
delay(60000); // settle, in clean air
zeroV = ads.computeVolts(ads.readADC_SingleEnded(0));
}
void loop() {
float v = ads.computeVolts(ads.readADC_SingleEnded(0)) - zeroV;
float ppm = v / GAIN_V_PER_NA / NA_PER_PPM;
Serial.print(ppm, 1); Serial.println(" ppm");
delay(1000);
}Setup and tuning
use a potentiostat or transimpedance amplifier circuit from the datasheet; modules may include it.
keep the reference and working electrodes shorted when stored, if required.
calibrate with known gas for accurate ppm.
most last 2 to 3 years.
allow stabilisation after power-up.
What you need
Shop this list20 of 20 found in our store · ₹1,00,545
Winsen ME3-CO Electrochemical Carbon Monoxide Sensor – 0-1000ppm Range: the part this guide coversWinsen ME3-CO Electrochemical Carbon Monoxide Sensor – 0-1000ppm Range₹1,499
Winsen ME3-H2S Hydrogen Sulfide Sensor – Electrochemical Gas Sensor: another version this guide coversWinsen ME3-H2S Hydrogen Sulfide Sensor – Electrochemical Gas Sensor₹953
Winsen ME3-NH3 Electrochemical Ammonia Sensor – 0-50 ppm Range: another version this guide coversWinsen ME3-NH3 Electrochemical Ammonia Sensor – 0-50 ppm Range₹6,279
Winsen ME3-NO2 Electrochemical Nitrogen Dioxide Gas Sensor – 0-20ppm Range: another version this guide coversWinsen ME3-NO2 Electrochemical Nitrogen Dioxide Gas Sensor – 0-20ppm Range₹6,759
Winsen ME3-SO2 Electrochemical SO2 Gas Sensor – 0-20ppm Range: another version this guide coversWinsen ME3-SO2 Electrochemical SO2 Gas Sensor – 0-20ppm Range₹9,869
Winsen ME3-HF Electrochemical Hydrogen Fluoride Sensor – 0-10ppm Range: another version this guide coversWinsen ME3-HF Electrochemical Hydrogen Fluoride Sensor – 0-10ppm Range₹8,639
Winsen ME3-O3 Ozone Gas Sensor Module – Electrochemical Sensor: another version this guide coversWinsen ME3-O3 Ozone Gas Sensor Module – Electrochemical Sensor₹8,839
Winsen ME3-SO2/HCL Electrochemical Gas Sensor – 0-20ppm SO2/HCL Detection: another version this guide coversWinsen ME3-SO2/HCL Electrochemical Gas Sensor – 0-20ppm SO2/HCL Detection₹7,239
Winsen ME4-CO CO Gas Sensor Electrochemical Module: another version this guide coversWinsen ME4-CO CO Gas Sensor Electrochemical Module₹3,939
Winsen ME4-H2 Hydrogen Gas Sensor Module – 0-1000ppm Electrochemical: another version this guide coversWinsen ME4-H2 Hydrogen Gas Sensor Module – 0-1000ppm Electrochemical₹13,150
Winsen ME4-NH3 Ammonia Gas Sensor – 0-50ppm Range, Constant Potential Electrolysis: another version this guide coversWinsen ME4-NH3 Ammonia Gas Sensor – 0-50ppm Range, Constant Potential Electrolysis₹10,019
Winsen MED-2CO Electrochemical Carbon Monoxide Sensor – 0-200ppm Range: another version this guide coversWinsen MED-2CO Electrochemical Carbon Monoxide Sensor – 0-200ppm Range₹4,999
Winsen MED-NH3 Electrochemical NH3 Gas Sensor – High Sensitivity Ammonia Detection: another version this guide coversWinsen MED-NH3 Electrochemical NH3 Gas Sensor – High Sensitivity Ammonia Detection₹9,879
Winsen ME2-CO Carbon Monoxide Gas Detection Sensor Module – UART & Analog Output: another version this guide coversWinsen ME2-CO Carbon Monoxide Gas Detection Sensor Module – UART & Analog Output₹489
Asair ACM3000 Carbon Monoxide Gas Sensor – 0-1000 ppm Electrochemical: another version this guide coversAsair ACM3000 Carbon Monoxide Gas Sensor – 0-1000 ppm Electrochemical₹479
Asair AHS3000 Hydrogen Sulfide Gas Sensor – 0-100ppm Electrochemical: another version this guide coversAsair AHS3000 Hydrogen Sulfide Gas Sensor – 0-100ppm Electrochemical₹689
Figaro Engineering TGS5042-A00 Carbon Monoxide Sensor – Electrochemical AA-Battery Package: another version this guide coversFigaro Engineering TGS5042-A00 Carbon Monoxide Sensor – Electrochemical AA-Battery Package₹1,549
Figaro Engineering TGS5141-P00 Carbon Monoxide Sensor – 0-5000ppm, Battery Operable: another version this guide coversFigaro Engineering TGS5141-P00 Carbon Monoxide Sensor – 0-5000ppm, Battery Operable₹1,219
Figaro Engineering CMM5042 Embedded Module for Carbon Monoxide – Electrochemical CO Sensor: another version this guide coversFigaro Engineering CMM5042 Embedded Module for Carbon Monoxide – Electrochemical CO Sensor₹3,859
ADS1115 16-bit 4-channel ADC module: to read small sensor voltages accuratelyADS1115 16-Bit 4-Channel ADC Module₹199
Alternatives and when to choose them
- Electrochemical gas sensors: background.
- Winsen ZE03 modules: the same cells with electronics.
- Oxygen sensors: galvanic O2 cells.
Common mistakes to avoid
- Reading the cell without amplifier.
- No calibration.
- Using past their life.
- Using as a certified alarm.
Frequently asked questions
Can I connect an ME3 sensor directly to Arduino?
No. It outputs nanoamps, so use an amplifier board or ready module.
How accurate are electrochemical sensors?
Good selectivity, typically within a few percent after calibration.
How long do they last?
About 2 to 3 years, after which readings drop and the cell needs replacing.
Why does the reading drift?
Temperature changes and ageing shift the reading; recalibrate regularly.
Are they safety certified?
No. Use certified gas detectors where people's safety depends on it.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.