How-to · Intermediate · 3 min read
Pressure Transducers and Transmitters
0.5-4.5 V, 4-20 mA and How to Wire Them
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
A pressure transducer turns fluid or gas pressure into an electrical signal. The two common outputs are a 0.5 to 4.5 V ratiometric voltage on 5 V supply and a 4 to 20 mA current loop. Choose the pressure range, thread and wetted material first, then read the signal with an ADC and scale it to the range.
Key specs at a glance
- Output 0.5-4.5 V
- 5 V supply, 3 wires, ratiometric; read directly with a 5 V ADC
- Output 4-20 mA
- 9 to 36 V supply, 2 wires; add a 250 Ω shunt to get 1 to 5 V
- Pressure types
- Gauge, absolute, sealed gauge, differential
- Ranges
- From a few kPa up to hundreds of bar
- Threads
- G1/4, 1/4 NPT, M12 and others
- Media
- Check that the wetted material suits water, oil, air or chemicals
Gauge, absolute and differential
Gauge sensors read relative to the air around them, absolute sensors relative to a vacuum, and differential sensors the difference between two ports. Gauge pressure is the usual choice for tanks and pipes. A tyre or water-line sensor is gauge; a barometer or altimeter is absolute.
Voltage or current output
Pick the output that fits your cable run and controller.
| Output | Wires | Best for | Notes |
|---|---|---|---|
| 0.5-4.5 V (ratiometric) | 3: +5 V, GND, signal | Short runs to an Arduino or ESP32 | Output scales with supply; use a 5 V ADC or a divider for 3.3 V |
| 0-5 V / 0-10 V | 3 or 4 | PLC and panel inputs | Check the supply voltage |
| 4-20 mA | 2 | Long cables and noisy plants | Needs loop supply of 12 to 24 V; broken wire reads 0 mA |
| I2C / SPI chip | 4 | Small boards, low pressure | Chip-level sensors; pressure port on the board |
- 0.5-4.5 V (ratiometric)
- Wires:
- 3: +5 V, GND, signal
- Best for:
- Short runs to an Arduino or ESP32
- Notes:
- Output scales with supply; use a 5 V ADC or a divider for 3.3 V
- 0-5 V / 0-10 V
- Wires:
- 3 or 4
- Best for:
- PLC and panel inputs
- Notes:
- Check the supply voltage
- 4-20 mA
- Wires:
- 2
- Best for:
- Long cables and noisy plants
- Notes:
- Needs loop supply of 12 to 24 V; broken wire reads 0 mA
- I2C / SPI chip
- Wires:
- 4
- Best for:
- Small boards, low pressure
- Notes:
- Chip-level sensors; pressure port on the board
Converting the signal to pressure
For a 0.5 to 4.5 V sensor with a range of 0 to 10 bar, 0.5 V is 0 bar and 4.5 V is 10 bar. Scale linearly. For 4-20 mA, put a 250 Ω shunt resistor across the loop return so 4 mA reads 1 V and 20 mA reads 5 V. See the shunt resistor calculator.
const float P_MAX = 10.0; // sensor range, bar
void setup() { Serial.begin(115200); }
void loop() {
float v = analogRead(A0) * 5.0 / 1023.0;
float bar = (v - 0.5) / 4.0 * P_MAX; // 0.5 V = 0, 4.5 V = full scale
if (bar < 0) bar = 0;
Serial.print(bar); Serial.println(" bar");
delay(250);
}Choosing the right one
- 1Range: select a range so normal pressure sits in the middle and the peak is no more than about 80 % of full scale. Spikes beyond the rating can damage the sensor.
- 2Wetted material: stainless steel suits water, air and most oils. Ceramic suits harsher media. Confirm compatibility before using on chemicals.
- 3Thread and seal: match G, NPT or M thread and use the correct sealing washer or tape.
- 4Electrical connector: Packard, Hirschmann or flying leads, depending on the sensor.
- 5Protection: use a snubber or pulsation damper on pumps.
Try it: Pressure converter calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Buying a range much larger than the real pressure and losing resolution.
- Connecting a 5 V output straight to a 3.3 V ADC.
- Forgetting the loop supply on a 4-20 mA sensor.
- Using the wrong thread or sealing method and leaking.
- Applying pressure spikes beyond the rated overpressure.
Frequently asked questions
What is the difference between a transducer and a transmitter?
A transducer usually outputs a millivolt or voltage signal, a transmitter a conditioned 4-20 mA signal. The names are often used loosely.
Can I read 4-20 mA with Arduino?
Yes, with a 250 Ω precision shunt across the loop return and an ADC input, or with a 4-20 mA input module.
What does ratiometric mean?
The output is a fixed fraction of the supply voltage, so it follows supply changes. Use the same 5 V for the sensor and the ADC reference.
Which unit should I use?
Use bar, kPa or psi to match the sensor label; see the pressure converter.
Can I use it for liquid level?
Yes, a submersible transmitter reads the water column pressure, about 1 bar per 10 m of water.
Parts for this guide
Calculators
Terms in this guide
Keep learning
Sources