Same-day dispatch before 2 PM · Free delivery over ₹999 · GST invoices Get the appPrices incl. GST
Geekobot
Snap & SendNEWGeeko AIWhere's myOrder
Log in
Products
  • Projects
    • Component guidesHow parts work, with code you can run
    • Learning pathsFrom your first LED to your first robot
    • Workshops & eventsOnline sessions for makers and classes
    • ElectrolarkFree guided builds, simulator and certificates
    • Students & teachersStudent discount and classroom help
    • CommunityShare builds and ask other makers
    • CalculatorsOhm's law, LED resistor, 555 and 100+ more
    • Circuit builderWire parts and run the circuit, powered by Electrolark
    • Geeko AIAsk what to buy or how to wire it
    • Snap & SendPhotograph a part or list, we find it
    • Part finderAnswer a few questions, get the right part
    • Compatibility checkWill these two parts work together?
    • Compare partsSpecs side by side
    • Business & bulk ordersGST invoices, credit and volume prices
    • Request a quotationSend your list, get a quote
    • Classroom kitsPer-student kits and lab bundles
    • Gift cardsFor students, teams and events
  • Atal Tinkering Lab
BOM to cart
Geekobot

Components, kits and know-how for makers, students, engineers, labs and businesses across India.

Ask Geeko AIOrders, parts and projects, any timeEmail supportReply within 1 working dayGet the Geekobot appAdd it to your home screen, free

Follow us

Shop

  • Boards & SBCs
  • Sensors & Modules
  • IoT & Wireless
  • Drone & FPV
  • 3D Printing
  • Filaments & Resins
  • Motors & Drivers
  • Power & Batteries
  • Semiconductors
  • Passive
  • Displays & LEDs
  • Switches & Relays
  • Wires & Cables
  • Prototyping
  • Tools & Test
  • Robotics
  • STEM Kits
  • Atal Tinkering Lab
  • Mechanical Parts
  • Audio

Orders

  • Track your order
  • Help & support
  • Shipping and delivery
  • Refunds and cancellation
  • Contact us

Learn

  • Projects
  • Geeko AI project assistant
  • Learning paths
  • Guides
  • Calculators
  • Electrolark: free guided builds

Part tools

  • Part finder
  • Compare parts
  • Will it work with my board?

Institutions

  • Classroom kits
  • Atal Tinkering Lab
  • Students & teachers
  • Workshops & Events

Business

  • Business & education
  • Request a quotation
  • BOM bulk upload
  • Quick order by SKU

Company

  • About Geekobot
  • Community
  • Gift cards
  • Terms & conditions
  • Privacy policy
  • Product directory
  • Sitemap

© 2026 Geekobot, a trade name of OLatus Systems Private Limited. All rights reserved.

20, 1st Floor, Neeladri Complex, 10th Cross, Sampige Rd, 2nd Main, Malleshwaram, Bengaluru, Karnataka 560003 · GSTIN 29AACCO0462F1ZM

+91 91810 15607 · connect@geekobot.in · Monday to Saturday, 10 AM to 2 PM IST

UPI · CARDS · NETBANKING · GST INVOICES

ShopProjectsGeeko AIGuides
Compare 0 parts →
Log in

Shop by category

Shop all components
  • Boards & SBCs1,910 products
    • Alternative Single Board Computers
    • Arduino Ecosystem
    • FPGA & Logic Boards
    • Microcontroller & Wireless Boards
    View all
  • Sensors & Modules4,701 products
    • Biomedical & Heart Rate
    • Current, Voltage & Power
    • Force, Weight & Pressure
    • Gas, Weather & Environmental
    View all
  • IoT & Wireless2,314 products
    • RF Modules
    • RFID & NFC
    • Antennas & RF Accessories
    • Cameras & Smart Vision
    View all
  • Drone & FPV3,558 products
    • Flight Control & Navigation
    • FPV Video & Optics
    • Frames & Structural Parts
    • Motors & Propulsion
    View all
  • 3D Printing2,204 products
    • 3D Printers
    • 3D Scanners & Digitizers
    • Laser Engravers & Cutters
    • Material Management & Upgrades
    View all
  • Filaments & Resins1,472 products
    • Filaments
    • Photopolymer Resins
    View all
  • Motors & Drivers463 products
    • BLDC Motor Drivers
    • DC & Geared Motors
    • DC Motor Drivers
    • Linear Actuators & Solenoids
    View all
  • Power & Batteries557 products
    • Battery Holders & Connectors
    • Breadboard Power
    • Chargers & BMS
    • DC-DC Converters
    View all
  • Semiconductors295 products
    • Diodes & Rectifiers
    • Interface & RF Encoder ICs
    • Logic ICs (74xx)
    • Logic ICs (CD4000)
    View all
  • Passive67 products
    • Capacitors
    • Circuit Protection
    • Crystals & Oscillators
    • Inductors
    View all
  • Displays & LEDs572 products
    • 7-Segment & Dot Matrix
    • Addressable LEDs
    • Character LCDs
    • Graphic LCDs
    View all
  • Switches & Relays184 products
    • Keypads & Touch
    • Push Buttons & Tactile
    • Relay Modules
    • Relays
    View all
  • Wires & Cables233 products
    • Board-to-Wire Connectors
    • Crimp & Splice
    • Headers & Dupont
    • Heat Shrink & Sleeving
    View all
  • Prototyping101 products
    • Breadboards
    • Interface Modules
    • PCBs & Perfboards
    View all
  • Tools & Test717 products
    • Bench Power Supplies
    • Hand Tools
    • Measuring Tools
    • Meters & Testers
    View all
  • Robotics180 products
    • Humanoid & Legged Robots
    • Robot Chassis & Platforms
    • Robotic Arms & Grippers
    • Wheels & Casters
    View all
  • STEM Kits268 products
    • Arduino Learning Kits
    • Coding & IoT Kits
    • Early Coding (Ages 3-8)
    • Invention Kits
    View all
  • Atal Tinkering Lab196 products
    • Package 1: Electronics, Robotics, IoT and Sensors
    • Package 2: Rapid Prototyping Tools
    • Package 3: Mechanical, Electrical and Measurement Tools
    • Package 4: Power Supply, Accessories and Safety Equipment
    View all
  • Mechanical Parts212 products
    • Bearings
    • Brackets & Mounts
    • Couplers
    • Fasteners & Standoffs
    View all
  • Audio109 products
    • Amplifier Modules
    • Buzzers & Sirens
    • Speakers
    View all
  1. Home
  2. ›Guides
  3. ›Sensors
  4. ›RS485 Modbus Water Quality Sensors

Component guide · Advanced · 7 min read

RS485 Modbus Water Quality Sensors

Renke, Desun Uniwill and FirstRate pH, ORP, Conductivity, Dissolved Oxygen, Turbidity, Residual Chlorine, COD, BOD, TOC, Ammonia, Nitrate, Chlorophyll and Oil-in-Water

By Geekobot Learning Team · Updated 29 Oct 2026

On this page
Short answerWhat the RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD) isRS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD) pinoutWiring the RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD)Example codeSetup and tuningWhat you needAlternatives and when to choose themCommon mistakesFAQsParts and next steps
Short answer

These sensors measure water quality and report it over RS485 Modbus RTU, so a PLC, data logger or ESP32 with a converter can read them directly. Use them for fish farms, water treatment, swimming pools, effluent and river monitoring. pH and ORP sensors need regular calibration; optical sensors such as fluorescence DO and turbidity need less, and some have automatic wiper cleaning.

Key specs at a glance

Parameters
pH, ORP, EC/TDS, DO, turbidity, chlorine, COD, BOD, TOC, NH4-N, NO3-N, chlorophyll, oil in water
Output
RS485 Modbus RTU, some also 4-20mA
Supply
Typically 12-24V DC
Protection
IP68 immersion types
Temperature
Built-in compensation on most
Cleaning
Automatic brush on some optical sensors

Models in this guide

These are alternatives. Pick the one that fits your project; you only need one.

  • Option 1Renke RS-PH-N01-2-201T Industrial pH Sensor, 0-14.00pH, 0-80°C, RS485/4-20mA/0-5V/0-10V Output, IP65₹15,369
  • Option 2FirstRate FST100-PH104A pH Sensor, Range: 0-14pH, RS485 Modbus, 5m Cable, NPT3/4 Port, IP68₹17,839
  • Option 3SN-300HHT-PH-N01-201T Handheld Water Quality pH Transmitter (RS485 Modbus)₹12,420
  • Option 4Renke RS-ORP-N01-2-300 ORP Sensor -1999~1999mV, RS485 Modbus₹15,749
  • Option 5SN-3003-ORP-N01-300T Industrial ORP Sensor with Temperature Probe – RS485 Modbus, IP68 Waterproof₹7,829
  • Option 6Renke RS-EC-N01-2-SUS01 Water Conductivity Sensor -20~100℃, RS485/4-20mA/0-10V/0-5V Output₹14,619
01

What the RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD) is

RS485 water quality sensors measure pH, EC/TDS, dissolved oxygen, turbidity, ORP or chlorine and report readings over Modbus for aquaculture, hydroponics and water treatment.

Start from the parameter you must control: pH and ORP for pools and dosing, DO for aquaculture aeration, EC for nutrient and salinity, turbidity and chlorine for drinking water, and COD, BOD, ammonia or nitrate for effluent reports.

Each sensor has its own Modbus address, so several can share one RS485 line if you give them different addresses. Calibrate pH with buffer solutions (for example 4.00, 6.86 and 9.18) as the manual says, keep electrodes wet, and clean optical windows on a schedule.

02

RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD) pinout

The pins on the RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD) and what each one does.

PinFunction
Brown or red+V supply, 5-30V or 12-24V DC
Black0V
Yellow or greenRS485 A (D+)
Blue or whiteRS485 B (D-)
ShieldEarth at one end only
PinFunction
Brown or red
+V supply, 5-30V or 12-24V DC
Black
0V
Yellow or green
RS485 A (D+)
Blue or white
RS485 B (D-)
Shield
Earth at one end only
03

Wiring the RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD)

Keep the electrode wet when stored. Give each sensor a unique Modbus address before connecting several to one bus.

RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD) pinConnectionNote
+V12 or 24V DC supplyCheck the label
0VSupply 0VCommon with the converter GND
AConverter A / D+Twisted pair
BConverter B / D-Terminate long runs with 120 ohm
+V
Connection:
12 or 24V DC supply
Note:
Check the label
0V
Connection:
Supply 0V
Note:
Common with the converter GND
A
Connection:
Converter A / D+
Note:
Twisted pair
B
Connection:
Converter B / D-
Note:
Terminate long runs with 120 ohm
04

Example code

Register addresses, decimals and default baud differ by maker. Check the sensor's Modbus table before trusting a value.

Read a Modbus RTU water sensor from a PC · MicroPython
# pip install minimalmodbus
import minimalmodbus, time

s = minimalmodbus.Instrument("/dev/ttyUSB0", 1)   # COM3 on Windows, slave address 1
s.serial.baudrate = 4800      # many Renke-style sensors ship at 4800; others use 9600
s.serial.timeout = 1

while True:
    raw = s.read_register(0, 2)   # register 0 with 2 decimals; see the sensor's register map
    print("Reading:", raw)
    time.sleep(2)
05

Setup and tuning

Power

typically 12 to 24 V DC.

Wiring

A and B to RS485; keep cables away from pumps and motors.

Calibration

calibrate pH with buffer solutions and EC with standard solutions regularly.

Installation

keep probes submerged at the right depth and away from bubbles.

Cleaning

clean probes on a schedule to prevent fouling.

06

What you need

Shop this list20 of 20 found in our store · ₹5,12,221

  • Renke RS-PH-N01-2-201T Industrial pH Sensor, 0-14.00pH, 0-80°C, RS485/4-20mA/0-5V/0-10V Output, IP65: the part this guide coversRenke RS-PH-N01-2-201T Industrial pH Sensor, 0-14.00pH, 0-80°C, RS485/4-20mA/0-5V/0-10V Output, IP65₹15,369
  • FirstRate FST100-PH104A pH Sensor, Range: 0-14pH, RS485 Modbus, 5m Cable, NPT3/4 Port, IP68: another version this guide coversFirstRate FST100-PH104A pH Sensor, Range: 0-14pH, RS485 Modbus, 5m Cable, NPT3/4 Port, IP68₹17,839
  • SN-300HHT-PH-N01-201T Handheld Water Quality pH Transmitter (RS485 Modbus): another version this guide coversSN-300HHT-PH-N01-201T Handheld Water Quality pH Transmitter (RS485 Modbus)₹12,420
  • Renke RS-ORP-N01-2-300 ORP Sensor -1999~1999mV, RS485 Modbus: another version this guide coversRenke RS-ORP-N01-2-300 ORP Sensor -1999~1999mV, RS485 Modbus₹15,749
  • SN-3003-ORP-N01-300T Industrial ORP Sensor with Temperature Probe – RS485 Modbus, IP68 Waterproof: another version this guide coversSN-3003-ORP-N01-300T Industrial ORP Sensor with Temperature Probe – RS485 Modbus, IP68 Waterproof₹7,829
  • Renke RS-EC-N01-2-SUS01 Water Conductivity Sensor -20~100℃, RS485/4-20mA/0-10V/0-5V Output: another version this guide coversRenke RS-EC-N01-2-SUS01 Water Conductivity Sensor -20~100℃, RS485/4-20mA/0-10V/0-5V Output₹14,619
  • Renke RS-EC-N01-3-10-EX Integrated Conductivity Sensor (RS485 Modbus-RTU) K=10, 5m Cable: another version this guide coversRenke RS-EC-N01-3-10-EX Integrated Conductivity Sensor (RS485 Modbus-RTU) K=10, 5m Cable₹11,189
  • SN-3003-EC-N01-01 Four Electrodes EC Sensor – RS485 Modbus, IP68 Waterproof: another version this guide coversSN-3003-EC-N01-01 Four Electrodes EC Sensor – RS485 Modbus, IP68 Waterproof₹14,689
  • FirstRate FST100-EC106 Electrical Conductivity Sensor, Range: 0-5000uS/cm, RS485 Modbus, 4-20mA, Stainless Steel, IP68, 5m Cable: another version this guide coversFirstRate FST100-EC106 Electrical Conductivity Sensor, Range: 0-5000uS/cm, RS485 Modbus, 4-20mA, Stainless Steel, IP68, 5m Cable₹26,569
  • Desun Uniwill DS480 Conductivity Sensor, 0-300mS/cm, RS485 Output, IP68 Waterproof: another version this guide coversDesun Uniwill DS480 Conductivity Sensor, 0-300mS/cm, RS485 Output, IP68 Waterproof₹33,019
  • Renke SN-300HHT-EC-N01-01 Handheld Water Quality EC Transmitter – RS485 Modbus, 2.8″ Display: another version this guide coversRenke SN-300HHT-EC-N01-01 Handheld Water Quality EC Transmitter – RS485 Modbus, 2.8″ Display₹18,029
  • Desun Uniwill DS285 TDS Sensor, 0-60PPT, RS485 Modbus Output, SS316 + PPEK Body, IP68: another version this guide coversDesun Uniwill DS285 TDS Sensor, 0-60PPT, RS485 Modbus Output, SS316 + PPEK Body, IP68₹34,649
  • LFS1305 CLASS C / F0.6 Conductivity Sensor 100 µS/cm–200 mS/cm, 4 Electrode: another version this guide coversLFS1305 CLASS C / F0.6 Conductivity Sensor 100 µS/cm–200 mS/cm, 4 Electrode₹4,499
  • Renke RS-LDO-N01-2-20 Dissolved Oxygen Sensor, 0~20mg/L, IP68, RS485 Modbus, 5m Cable: another version this guide coversRenke RS-LDO-N01-2-20 Dissolved Oxygen Sensor, 0~20mg/L, IP68, RS485 Modbus, 5m Cable₹17,129
  • SN-3001-LDO-N01-20 Fluorescence Dissolved Oxygen Sensor – RS485 Output, IP68: another version this guide coversSN-3001-LDO-N01-20 Fluorescence Dissolved Oxygen Sensor – RS485 Output, IP68₹13,959
  • FirstRate FST100-DO202A Dissolved Oxygen Sensor, 0-20 mg/L, RS485 Output, 5m Cable, IP68, NPT3/4 Port: another version this guide coversFirstRate FST100-DO202A Dissolved Oxygen Sensor, 0-20 mg/L, RS485 Output, 5m Cable, IP68, NPT3/4 Port₹30,639
  • Desun Uniwill DS380 Fluorescence Dissolved Oxygen Sensor, 0–20 mg/L, RS485 Modbus Output, IP68 Submersible: another version this guide coversDesun Uniwill DS380 Fluorescence Dissolved Oxygen Sensor, 0–20 mg/L, RS485 Modbus Output, IP68 Submersible₹47,549
  • Desun Uniwill DYS-1 Portable Dissolved Oxygen Meter with DS380 Sensor, 0-20mg/l, RS485 Modbus Output: another version this guide coversDesun Uniwill DYS-1 Portable Dissolved Oxygen Meter with DS380 Sensor, 0-20mg/l, RS485 Modbus Output₹62,999
  • Renke RS-ZD-N01-1S-1000 Turbidity Sensor 0-4000NTU, IP68, RS485 Modbus, 5m Cable: another version this guide coversRenke RS-ZD-N01-1S-1000 Turbidity Sensor 0-4000NTU, IP68, RS485 Modbus, 5m Cable₹27,359
  • FirstRate ST100-ZD102 Turbidity Sensor, 0-4000 NTU, 4-20mA & RS485 Modbus, 316 Stainless Steel, IP68, 5m Cable: another version this guide coversFirstRate ST100-ZD102 Turbidity Sensor, 0-4000 NTU, 4-20mA & RS485 Modbus, 316 Stainless Steel, IP68, 5m Cable₹86,119
07

Alternatives and when to choose them

  • ✓Analog pH sensor: low-cost maker option.
  • ✓Analog turbidity sensor: simple turbidity.
  • ✓pH and TDS pen meters: spot checks by hand.
08

Common mistakes to avoid

  • !Skipping calibration.
  • !Letting probes dry out.
  • !Placing probes in bubbles.
  • !Running cables next to pump wires.
09

Frequently asked questions

How often should I calibrate a pH probe?

Every 2 to 4 weeks in continuous use, with pH 4 and 7 buffers.

Why does the pH reading drift?

Fouling on the glass bulb, an ageing probe or missed calibration all cause drift.

Can I use several water sensors on one bus?

Yes, as long as each sensor has a unique Modbus address.

Why are dissolved oxygen readings unstable?

Bubbles on the membrane or too little water flow past the probe.

How long do pH probes last?

About 1 to 2 years, depending on the water and how well they are kept wet.

Parts for this guide

  • Renke RS-PH-N01-2-201T Industrial pH Sensor, 0-14.00pH, 0-80°C, RS485/4-20mA/0-5V/0-10V Output, IP65
    ₹15,369View
  • FirstRate FST100-PH104A pH Sensor, Range: 0-14pH, RS485 Modbus, 5m Cable, NPT3/4 Port, IP68
    ₹17,839View
  • SN-300HHT-PH-N01-201T Handheld Water Quality pH Transmitter (RS485 Modbus)
    ₹12,420View
  • Renke RS-ORP-N01-2-300 ORP Sensor -1999~1999mV, RS485 Modbus
    ₹15,749View
  • SN-3003-ORP-N01-300T Industrial ORP Sensor with Temperature Probe – RS485 Modbus, IP68 Waterproof
    ₹7,829View
  • Renke RS-EC-N01-2-SUS01 Water Conductivity Sensor -20~100℃, RS485/4-20mA/0-10V/0-5V Output
    ₹14,619View
  • Renke RS-EC-N01-3-10-EX Integrated Conductivity Sensor (RS485 Modbus-RTU) K=10, 5m Cable
    ₹11,189View
  • SN-3003-EC-N01-01 Four Electrodes EC Sensor – RS485 Modbus, IP68 Waterproof
    ₹14,689View
  • FirstRate FST100-EC106 Electrical Conductivity Sensor, Range: 0-5000uS/cm, RS485 Modbus, 4-20mA, Stainless Steel, IP68, 5m Cable
    ₹26,569View
  • Desun Uniwill DS480 Conductivity Sensor, 0-300mS/cm, RS485 Output, IP68 Waterproof
    ₹33,019View
  • Renke SN-300HHT-EC-N01-01 Handheld Water Quality EC Transmitter – RS485 Modbus, 2.8″ Display
    ₹18,029View
  • Desun Uniwill DS285 TDS Sensor, 0-60PPT, RS485 Modbus Output, SS316 + PPEK Body, IP68
    ₹34,649View
  • LFS1305 CLASS C / F0.6 Conductivity Sensor 100 µS/cm–200 mS/cm, 4 Electrode
    ₹4,499View
  • Renke RS-LDO-N01-2-20 Dissolved Oxygen Sensor, 0~20mg/L, IP68, RS485 Modbus, 5m Cable
    ₹17,129View
  • SN-3001-LDO-N01-20 Fluorescence Dissolved Oxygen Sensor – RS485 Output, IP68
    ₹13,959View
  • FirstRate FST100-DO202A Dissolved Oxygen Sensor, 0-20 mg/L, RS485 Output, 5m Cable, IP68, NPT3/4 Port
    ₹30,639View
  • Desun Uniwill DS380 Fluorescence Dissolved Oxygen Sensor, 0–20 mg/L, RS485 Modbus Output, IP68 Submersible
    ₹47,549View
  • Desun Uniwill DYS-1 Portable Dissolved Oxygen Meter with DS380 Sensor, 0-20mg/l, RS485 Modbus Output
    ₹62,999View
  • Renke RS-ZD-N01-1S-1000 Turbidity Sensor 0-4000NTU, IP68, RS485 Modbus, 5m Cable
    ₹27,359View
  • FirstRate ST100-ZD102 Turbidity Sensor, 0-4000 NTU, 4-20mA & RS485 Modbus, 316 Stainless Steel, IP68, 5m Cable
    ₹86,119View
  • Desun Uniwill DSS410 Fiber Optical Turbidity Sensor, 0-4000NTU, RS485 Modbus Output, IP68 Waterproof
    ₹83,999View
  • FirstRate FST-100-YL106 Smart Residual Chlorine Sensor, 0-20mg/L, RS485 Modbus & 4-20mA Output
    ₹45,189View
  • Renke RS-CL-N01-3-20-EX Residual Chlorine Sensor, 0-20 mg/L, RS485/4-20mA/0-10V Output, 3/4″ Thread
    ₹25,769View
  • Renke SN-3003-CL-N01-20 Industrial Residual Chlorine Sensor (Fresh Water) – RS485 Modbus, IP68
    ₹43,789View
  • Renke RS-COD-N01-2-500-EX COD Sensor, 0-500 mg/L, RS485 Modbus, IP68 Waterproof
    ₹58,479View
  • Desun Uniwill DS500 COD Sensor, 0–2000 mg/L, RS485 Modbus Output, IP68 SS316/Titanium Body
    ₹1,70,079View
  • Desun Uniwill DS502 BOD Sensor, 0-1000mg/l, RS485 MODBUS Output, SS316/Titanium, IP68
    ₹1,73,399View
  • Desun Uniwill DS502 TOC Sensor, 0-1000mg/l, RS485 Output, IP68 Immersion Probe
    ₹1,73,399View
  • DSN260 NH₄ Ammonia Sensor, 0-1000mg/l – RS485 Modbus RTU
    ₹1,33,159View
  • Desun Uniwill DSN260 Ammonia Nitrogen Sensor, 0-1000mg/l, RS485 Modbus Output
    ₹1,17,299View
  • Desun Uniwill DSN260 Nitrate Sensor, 0-1000mg/l, RS485 Output, IP68 Waterproof, 5m Cable
    ₹1,33,059View
  • Renke RS-CH-N01-2-EX Chlorophyll Sensor with Automatic Cleaning – RS485 Modbus, 0-400ug/L
    ₹69,949View
  • Renke RS-OIL-N01-2-EX Oil in Water Sensor with Automatic Cleaning – RS485 Modbus
    ₹82,559View
  • USB to RS485 Converter Adapter
    ₹74View
  • 24V 4A AC-DC Switching Power Supply Board
    ₹411View
Shop Water, Liquid Level & Flow Sensors

Keep learning

Component guideIntermediateAnalog pH Sensor Kit (BNC Probe and PH-4502C Board)An analog pH kit pairs a glass pH electrode with a small amplifier board that turns the electrode's millivolts into a 0 to 5 V signal.3 min read · SensorsComponent guideBeginnerAnalog Turbidity Sensor (DFRobot SEN0189 Style)A turbidity sensor shines infrared light through water and measures how much is scattered by particles, so murky water gives a lower output voltage.4 min read · SensorsComponent guideBeginnerDigital pH Pen and TDS/EC MeterPen-style pH and TDS/EC meters are pocket testers for drinking water, aquariums, hydroponics and science labs.3 min read · Tools & Workshop Skills

Sources

  • Renke sensor manuals
  • Desun Uniwill and FirstRate data sheets

Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.

On this page
Short answerWhat the RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD) isRS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD) pinoutWiring the RS485 Modbus water quality sensors (pH, ORP, EC, DO, turbidity, chlorine, COD)Example codeSetup and tuningWhat you needAlternatives and when to choose themCommon mistakesFAQsParts and next steps
Need a hand?Ask Geeko AI which part fits your project, or talk to the Geekobot team.Ask Geeko AIHelp & support

Parts for this guide2 items · ₹19,868

Renke RS-PH-N01-2-201T Industrial pH Sensor, 0-14.00pH, 0-80°C, RS485/4-20mA/0-5V/0-10V Output, IP65 · LFS1305 CLASS C / F0.6 Conductivity Sensor 100 µS/cm–200 mS/cm, 4 Electrode

Run itChange the inputs and watch the output

Register 0 with two decimals, for example pH 7.12 or 1.85 mS/cm depending on the probe.

Shell
Reading: 7.11

A simulation of the sketch above, so you know what to expect. Real readings vary with your parts and wiring.

Ask the Community

Ask a question