Component guide · Intermediate · 4 min read
SGP40 and SGP41 VOC Index Sensors

Wiring and Code
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
The Sensirion SGP40 measures volatile organic compounds and gives a VOC Index from 1 to 500, where 100 is the room's normal level. The SGP41 adds a NOx Index for combustion gases. Both use I2C at address 0x59, need a humidity reading for compensation, and run Sensirion's Gas Index Algorithm in your code. They are the sensors inside many air purifiers.
Key specs at a glance
- Measures
- VOC Index (SGP40), VOC and NOx Index (SGP41)
- Output
- Index 1 to 500 (VOC, 100 = normal), 1 to 500 (NOx, 1 = normal)
- Interface
- I2C, address 0x59
- Supply
- 1.7 to 3.6 V (breakouts 3.3 to 5 V)
- Current
- About 3 mA while measuring
- Warm-up
- About 1 minute for VOC; the index learns over hours
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Adafruit SGP40 Air Quality Sensor Breakout – VOC Index – STEMMA QT/Qwiic₹2,446
Option 2DFRobot Gravity SGP40 Air Quality Sensor – I2C VOC Index₹1,499
Option 3GY-SGP40 Air Quality Sensor Module – SGP40 Metal Oxide Gas Sensor w/ I2C Interface & Header Pin₹1,009
Option 4Waveshare SGP40 VOC Gas Sensor I2C Module₹1,509
Option 5Sensirion SGP40-D-R4 Indoor Air Quality Sensor – Digital DFN 6-Pin₹479
Option 6SGP40 Digital Gas Sensor Module with Cotton Core & Card Holder – 1m Cable₹1,469
What the SGP40 / SGP41 sensor is
The sensor's metal-oxide element changes resistance with VOC levels. Rather than ppm, Sensirion's algorithm learns your room's normal air over time and reports how far the current air is from it: above 100 means worse than usual, below means better.
For accurate results, send it the current humidity and temperature from a sensor such as the SHT40 or SHTC3 before each reading.
SGP40 / SGP41 sensor pinout
The pins on the SGP40 / SGP41 sensor and what each one does.
| Pin | Function |
|---|---|
| VIN / VCC | Supply (3.3 or 5 V on breakouts) |
| GND | Ground |
| SDA | I2C data |
| SCL | I2C clock |
- VIN / VCC
- Supply (3.3 or 5 V on breakouts)
- GND
- Ground
- SDA
- I2C data
- SCL
- I2C clock
Wiring the SGP40 / SGP41 sensor
Most breakouts have pull-up resistors and a regulator, so they run from 3.3 V or 5 V. Bare sensor ICs are 3.3 V (or 1.8 V) only: solder them to a breakout first and use a level shifter with 5 V boards. Mount it with a humidity sensor next to it and read both once a second.
| SGP40 / SGP41 sensor pin | Arduino Uno | ESP32 |
|---|---|---|
| VCC | 5V (or 3.3V) | 3V3 |
| GND | GND | GND |
| SDA | A4 | GPIO 21 |
| SCL | A5 | GPIO 22 |
- VCC
- Arduino Uno:
- 5V (or 3.3V)
- ESP32:
- 3V3
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- SDA
- Arduino Uno:
- A4
- ESP32:
- GPIO 21
- SCL
- Arduino Uno:
- A5
- ESP32:
- GPIO 22
Example code
For the SGP41 use the Sensirion I2C SGP41 library with the Gas Index Algorithm library to get both VOC and NOx indexes.
#include <Adafruit_SGP40.h>
#include <Adafruit_SHTC3.h> // any humidity sensor works
Adafruit_SGP40 sgp;
Adafruit_SHTC3 sht;
void setup() {
Serial.begin(115200);
if (!sgp.begin()) { Serial.println("SGP40 not found"); while (1); }
sht.begin();
}
void loop() {
sensors_event_t hum, temp;
sht.getEvent(&hum, &temp);
int32_t voc = sgp.measureVocIndex(temp.temperature, hum.relative_humidity);
Serial.print("VOC Index: "); Serial.println(voc);
delay(1000); // the algorithm expects 1 reading per second
}Setup and tuning
the Gas Index Algorithm assumes a steady 1 Hz rate.
the index settles over several hours; do not judge it in the first few minutes.
always pass real humidity and temperature, or readings drift with weather.
it needs about 10 seconds of conditioning at start-up before NOx readings.
What you need
Shop this list14 of 15 found in our store · ₹17,056
Adafruit SGP40 Air Quality Sensor Breakout – VOC Index – STEMMA QT/Qwiic: the part this guide coversAdafruit SGP40 Air Quality Sensor Breakout – VOC Index – STEMMA QT/Qwiic₹2,446
DFRobot Gravity SGP40 Air Quality Sensor – I2C VOC Index: another version this guide coversDFRobot Gravity SGP40 Air Quality Sensor – I2C VOC Index₹1,499
Generic GY-SGP40 Air Quality Sensor Module – SGP40 Metal Oxide Gas Sensor w/ I2C Interface & Header Pin: another version this guide coversGY-SGP40 Air Quality Sensor Module – SGP40 Metal Oxide Gas Sensor w/ I2C Interface & Header Pin₹1,009
Waveshare SGP40 VOC Gas Sensor I2C Module: another version this guide coversWaveshare SGP40 VOC Gas Sensor I2C Module₹1,509
Sensirion SGP40-D-R4 Indoor Air Quality Sensor – Digital DFN 6-Pin: another version this guide coversSensirion SGP40-D-R4 Indoor Air Quality Sensor – Digital DFN 6-Pin₹479
SGP40 Digital Gas Sensor Module with Cotton Core & Card Holder – 1m Cable: another version this guide coversSGP40 Digital Gas Sensor Module with Cotton Core & Card Holder – 1m Cable₹1,469
Sensirion SGP40 VOC Sensor – Stainless Steel Probe w/ 1m Cable, I2C Digital Output: another version this guide coversSensirion SGP40 VOC Sensor – Stainless Steel Probe w/ 1m Cable, I2C Digital Output₹889
Adafruit SGP41 Multi-Pixel Gas Sensor Breakout – VOC & NOx Index – STEMMA QT / Qwiic: another version this guide coversAdafruit SGP41 Multi-Pixel Gas Sensor Breakout – VOC & NOx Index – STEMMA QT / Qwiic₹3,342
Generic GY-SGP41 Air Quality Sensor Module – I2C Interface: another version this guide coversGY-SGP41 Air Quality Sensor Module – I2C Interface₹1,239
Seeed Studio Studio Grove SGP41 Smart Air Quality Sensor (VOC & NOx) – I2C Grove Interface: another version this guide coversSeeed Studio Grove SGP41 Smart Air Quality Sensor (VOC & NOx) – I2C Grove Interface₹1,989
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389- Uno R3 development board: the controller used in the wiring tableFind this part
DFRobot SHTC3 humidity sensor: for humidity compensationDFRobot Fermion SHTC3 Humidity & Temperature Sensor – I2C Interface₹609
0.96 inch OLED display 128x64: to show readings without a computer0.96" OLED Display 128x64₹139Closest match, check the specs
Dupont jumper wires: for the connectionsDupont Jumper Wires (40 pcs)₹49Closest match, check the specs
Alternatives and when to choose them
- ENS160 air quality sensor: gives AQI, TVOC and eCO2 values directly.
- SCD40 and SCD41 CO2 sensors: true CO2 for ventilation decisions.
- VOC and indoor air quality sensors: how the options compare.
Try it: I2c pullup calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Expecting ppm values: the output is a relative index.
- Reading it irregularly, which confuses the algorithm.
- Skipping humidity compensation.
- Judging the readings before the sensor has learned the room.
Frequently asked questions
What does a VOC Index of 100 mean?
The air is at the room's normal level. Above 100 is worse than usual; below is better.
SGP40 or SGP41?
SGP41 if you also want NOx (cooking, gas stoves, traffic); SGP40 for VOCs only.
Does it measure CO2?
No. Use an NDIR sensor such as the SCD40 for CO2.
What is the I2C address?
0x59 for both.
Why does the index return to 100?
The algorithm adapts to long-lasting changes and treats them as the new normal.
Parts for this guide
Calculators
Projects that use it
Put this into practice: 1 step-by-step build in our project library uses parts from this guide.
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.