Shop all componentsGood growers keep records. The Mega logs air temperature and humidity, soil moisture and UV every five minutes to a CSV file. A season of data shows which weeks were too hot, when watering was late, and how the shade net changed the light.
Tick anything you already have and the total updates.
Measures air temperature (±0.5 °C) and relative humidity (±2–5 %) on a single data wire.
Capacitive probe that measures soil moisture without exposed metal, so it does not corrode like resistive probes.
Temperature-compensated real-time clock (±2 minutes a year) with a coin-cell backup, so the time survives power cuts.
Stores readings on a microSD card as a CSV file you can open in Excel or Google Sheets.
Follow the colours: red is power, dark grey is ground, blue is a signal.
mega_greenhouse_data_logger.inoVerify & upload in Electrolark// Greenhouse climate and soil logger on an Arduino Mega
// Geekobot project library · board: Arduino Mega 2560
// Wiring diagram, parts list and build steps: Geekobot project page "mega-greenhouse-data-logger"
#include <DHT.h>
#include <Wire.h>
#include <RTClib.h>
#include <SPI.h>
#include <SD.h>
// ---- pins ----
const uint8_t DHT_PIN = 22;
const uint8_t SOIL_PIN = A0;
const uint8_t UV_PIN = A1;
const uint8_t SD_CS = 53;
const int ADC_MAX = 1023; // 10-bit analog input
const float VREF = 5.0f;
DHT dht(DHT_PIN, DHT22);
const int SOIL_DRY = 520; // reading in dry air: calibrate
const int SOIL_WET = 260; // reading in a glass of water: calibrate
RTC_DS3231 rtc;
// ---- latest readings ----
float tempC = 0;
float humidity = 0;
int soilPct = 0;
float uvIndex = 0;
const unsigned long LOG_EVERY_MS = 300000UL; // one row per 300 s
unsigned long lastLog = 0;
bool cardOk = false;
void writeRow() {
File f = SD.open("LOG.CSV", FILE_WRITE);
if (!f) { Serial.println(F("Write failed")); return; }
DateTime t = rtc.now();
char stamp[20];
snprintf(stamp, sizeof(stamp), "%04d-%02d-%02d,%02d:%02d:%02d", t.year(), t.month(), t.day(), t.hour(), t.minute(), t.second());
f.print(stamp);
f.print(',');
f.print(tempC, 1);
f.print(',');
f.print(humidity, 0);
f.print(',');
f.print(soilPct);
f.print(',');
f.print(uvIndex, 1);
f.println();
f.close();
}
void setup() {
Serial.begin(115200);
dht.begin();
if (!rtc.begin()) Serial.println(F("RTC not found"));
if (rtc.lostPower()) rtc.adjust(DateTime(F(__DATE__), F(__TIME__))); // set from the upload time
cardOk = SD.begin(SD_CS);
Serial.println(cardOk ? F("SD card ready") : F("SD card not found"));
if (cardOk && !SD.exists("LOG.CSV")) {
File f = SD.open("LOG.CSV", FILE_WRITE);
if (f) { f.println(F("date,time,Temp(C),Humidity(%),Soil(%),UV index")); f.close(); }
}
}
void loop() {
if (millis() - lastLog < LOG_EVERY_MS && lastLog != 0) return;
lastLog = millis();
tempC = dht.readTemperature();
humidity = dht.readHumidity();
soilPct = constrain(map(analogRead(SOIL_PIN), SOIL_DRY, SOIL_WET, 0, 100), 0, 100);
uvIndex = analogRead(UV_PIN) * VREF / ADC_MAX / 0.1f;
Serial.print(F("Temp="));
Serial.print(tempC, 1);
Serial.print(F("C"));
Serial.print(F(", Humidity="));
Serial.print(humidity, 0);
Serial.print(F("%"));
Serial.print(F(", Soil="));
Serial.print(soilPct);
Serial.print(F("%"));
Serial.print(F(", UV index="));
Serial.print(uvIndex, 1);
Serial.println();
if (cardOk) writeRow();
}
The sketch above runs here on a simulated Arduino Mega. Move the sliders for the sensors and buttons it reads, and watch the Serial monitor, display and outputs change.
Check the DATA wire and the pull-up. The DHT22 needs at least 2 seconds between reads, so do not poll it faster.
Calibrate: note the raw reading in dry air and in water, and put them in SOIL_DRY and SOIL_WET.
Expected. Take it outside in daylight.
The coin cell is flat or missing. Some modules need the charging resistor removed when using a CR2032.
Check the card is FAT32, fully inserted, and CS is on the pin in the sketch.
Open the Serial Monitor at 115200 baud and check for messages. Make sure you chose the right board and port in the Arduino IDE.
Close other programs using the serial port, try another USB cable (some are charge-only) and press reset just before uploading.
Use a 5 V USB phone charger or a power bank into the board's USB port.
9 parts: MEGA 2560 R3 Dev Board with ATmega2560 & CH340G, DHT22 Temperature & Humidity Sensor, Capacitive Soil Moisture Sensor – 3.3V/5V Analog Output, GUVA-S12SD UV Sensor Module, DS3231 Precision RTC Module with EEPROM, DFRobot Fermion MicroSD Card Module – SPI, microSD Memory Card Class 10 (16GB), Solderless Breadboard (830 points) and Dupont Jumper Wires (40 pcs). Tools: Digital Multimeter and Wire Stripper and Cutter. On this page you can tick the parts you already have and add only the rest to your cart.
It is a intermediate project and takes about 2–3 hours. The build on this page has 11 steps.
No. This page has the complete, tested code (mega_greenhouse_data_logger.ino). Install these libraries first: DHT sensor library, Adafruit Unified Sensor, RTClib and SD.
Yes. The Run it panel under the code runs this exact sketch on a simulated board. Move the sliders or press the buttons for the sensors it reads, and the Serial monitor, display and outputs react as they will on the real build. It is a simulation, so real readings depend on your parts and wiring.
About ₹2,474 for the parts at the prices on this page, plus tools if you do not have them. Quantity price breaks lower the cost when you build several.
Calibrating an analog sensor with map(); Converting a voltage to a physical unit; Real-time clocks and backup batteries; SPI devices and CSV logging; Single-wire digital sensors and why some sensors need slow polling.
Ideas that reuse this build: Greenhouse data logger and Wi-Fi polyhouse climate. They are listed under Take it further on this page.
Your first MicroPython project: temperature and humidity on an OLED.
A web page with ON and OFF buttons that switches a relay over Wi-Fi.
A warm ring light that fades up at dusk and down at dawn.
Turn a Pi and a touchscreen into a home command centre with a clock and to-do list.
Learning project. Check every circuit and the datasheet of each part before you power it up.
%, UV index=15.0 Temp=27.0C, Humidity=55%, Soil=82%, UV index=15.0 Temp=27.1C, Humidity=55%, Soil=81%, UV index=15.0 Temp=27.0C, Humidity=55%, Soil=81%, UV index=15.1
A simulation of the sketch above, so you know what to expect. Real readings vary with your parts and wiring.