A bar load cell is an aluminium block with strain gauges glued inside a hole, wired as a full Wheatstone bridge. Bolt one end to the base and the other to the platform, and the bridge gives a few millivolts per volt as weight bends it. An HX711 amplifier turns that into a reading on Arduino or ESP32. Pick a capacity about 1.5 times your heaviest load.
Key specs at a glance
- Capacity
- 1kg to 200kg depending on model
- Output
- About 1.0 to 2.0 mV/V full scale
- Bridge
- Full bridge, 4 wires, about 1000 ohm
- Excitation
- 3 to 10V DC, 5V typical
- Mounting
- M4, M5 or M6 screws, one end fixed, other end loaded
- Material
- Aluminium alloy, some anodised
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Phaeton 613 N Load Cell Sensor 40KG – Screw-Fastened Strain Gauge₹130
Option 2Phaeton 616BA 1KG Aluminum Alloy Load Cell Sensor₹94
Option 3Phaeton B05 Load Cell Sensor 2-3KG – Screw-Fastened Strain Gauge₹109
Option 4Phaeton Big 6 Load Cell Sensor – 50kg Push Down, Screw-Fastened₹121
Option 5Phaeton CZL-400 Load Cell Sensor 7KG Weighing Screw-fastened₹68
Option 6Phaeton CZL-611CD-01 Load Cell Sensor 5KG Weighing Screw-fastened₹116
What the Bar (single-point) load cells: Phaeton CZL series, YZC-131 and YZC-133 is
A bar load cell is an aluminium beam with strain gauges inside that bends slightly under weight, giving a tiny voltage that an HX711 amplifier turns into a reading.
These suit kitchen and parcel scales, beehive scales, feeder and tank weighing, and robot or test-rig force readings. A single bar cell under the middle of a platform reads the whole load, so you do not need four cells and a combiner.
Follow the arrow on the side of the cell: it points the way the load should push. Fit spacers so only the gauge section can bend, and never let the cell touch the base or the platform anywhere except the screw pads.
Bar (single-point) load cells: Phaeton CZL series, YZC-131 and YZC-133 pinout
The pins on the Bar (single-point) load cells: Phaeton CZL series, YZC-131 and YZC-133 and what each one does.
| Pin | Function |
|---|---|
| Red | E+ (excitation +) |
| Black | E- (excitation -) |
| Green | S+ or A+ (signal +) |
| White | S- or A- (signal -) |
| Shield | Bare or yellow wire, to GND (optional) |
- Red
- E+ (excitation +)
- Black
- E- (excitation -)
- Green
- S+ or A+ (signal +)
- White
- S- or A- (signal -)
- Shield
- Bare or yellow wire, to GND (optional)
Wiring the Bar (single-point) load cells: Phaeton CZL series, YZC-131 and YZC-133
Colour codes vary by maker. Measure: about 1k between E+ and E-, and the same between S+ and S-.
| Bar (single-point) load cells: Phaeton CZL series, YZC-131 and YZC-133 pin | Connection | Note |
|---|---|---|
| Red | E+ | HX711 excitation |
| Black | E- | HX711 ground side |
| Green | A+ | Signal |
| White | A- | Swap A+ and A- if weight reads negative |
| HX711 DT | D3 | Data |
| HX711 SCK | D2 | Clock |
| HX711 VCC/GND | 5V / GND | Or 3.3V on ESP32 |
- Red
- Connection:
- E+
- Note:
- HX711 excitation
- Black
- Connection:
- E-
- Note:
- HX711 ground side
- Green
- Connection:
- A+
- Note:
- Signal
- White
- Connection:
- A-
- Note:
- Swap A+ and A- if weight reads negative
- HX711 DT
- Connection:
- D3
- Note:
- Data
- HX711 SCK
- Connection:
- D2
- Note:
- Clock
- HX711 VCC/GND
- Connection:
- 5V / GND
- Note:
- Or 3.3V on ESP32
Example code
Calibrate with a known weight: factor = raw reading after tare divided by the true weight. Each load cell needs its own factor.
#include "HX711.h"
const int DT_PIN = 3;
const int CLK_PIN = 2;
HX711 scale;
float factor = 420.0; // change until a known weight reads right
void setup() {
Serial.begin(9600);
scale.begin(DT_PIN, CLK_PIN);
scale.set_scale(factor);
scale.tare(); // empty platform = 0
Serial.println("Place a known weight");
}
void loop() {
Serial.print("Weight: ");
Serial.print(scale.get_units(10), 1); // average of 10 readings
Serial.println(" g");
delay(500);
}Setup and tuning
bolt one end to the base and the other to the platform, with spacers so the middle can bend freely.
load the cell in the direction of the arrow on its label.
connect red and black to E+ and E-, and green and white to A+ and A-; swap the signal pair if readings go negative.
tare with nothing on, then place a known weight and set the scale factor in code.
choose a cell rated about 1.5 times your largest load, so it is not overloaded.
What you need
Shop this list20 of 20 found in our store · ₹2,242
Phaeton 613 N Load Cell Sensor 40KG – Screw-Fastened Strain Gauge: the part this guide coversPhaeton 613 N Load Cell Sensor 40KG – Screw-Fastened Strain Gauge₹130
Phaeton 616BA 1KG Aluminum Alloy Load Cell Sensor: another version this guide coversPhaeton 616BA 1KG Aluminum Alloy Load Cell Sensor₹94
Phaeton B05 Load Cell Sensor 2-3KG – Screw-Fastened Strain Gauge: another version this guide coversPhaeton B05 Load Cell Sensor 2-3KG – Screw-Fastened Strain Gauge₹109
Phaeton Big 6 Load Cell Sensor – 50kg Push Down, Screw-Fastened: another version this guide coversPhaeton Big 6 Load Cell Sensor – 50kg Push Down, Screw-Fastened₹121
Phaeton CZL-400 Load Cell Sensor 7KG Weighing Screw-fastened: another version this guide coversPhaeton CZL-400 Load Cell Sensor 7KG Weighing Screw-fastened₹68
Phaeton CZL-611CD-01 Load Cell Sensor 5KG Weighing Screw-fastened: another version this guide coversPhaeton CZL-611CD-01 Load Cell Sensor 5KG Weighing Screw-fastened₹116
Phaeton CZL-611CF 6KG Aluminum Load Cell Sensor – Screw-Fastened: another version this guide coversPhaeton CZL-611CF 6KG Aluminum Load Cell Sensor – Screw-Fastened₹59
Phaeton CZL-611E Load Cell Sensor 200KG Downforce – Screw-Fastened: another version this guide coversPhaeton CZL-611E Load Cell Sensor 200KG Downforce – Screw-Fastened₹163
Phaeton CZL-611N 20KG Load Cell Sensor – Screw-fastened: another version this guide coversPhaeton CZL-611N 20KG Load Cell Sensor – Screw-fastened₹131
Phaeton CZL-611N Load Cell Sensor 1-2kg Screw-Fastened: another version this guide coversPhaeton CZL-611N Load Cell Sensor 1-2kg Screw-Fastened₹131
Phaeton CZL-611N Load Cell Sensor 10KG Screw-fastened: another version this guide coversPhaeton CZL-611N Load Cell Sensor 10KG Screw-fastened₹131
Phaeton CZL-611N Load Cell Sensor 5-7KG Screw-fastened: another version this guide coversPhaeton CZL-611N Load Cell Sensor 5-7KG Screw-fastened₹128
Phaeton CZL-611P Load Cell Sensor 40KG Aluminum Alloy: another version this guide coversPhaeton CZL-611P Load Cell Sensor 40KG Aluminum Alloy₹145
Phaeton CZL-611RD Aluminum Alloy Load Cell Sensor 10kg – Screw-Fastened: another version this guide coversPhaeton CZL-611RD Aluminum Alloy Load Cell Sensor 10kg – Screw-Fastened₹177
Phaeton CZL-611RD-20KG Load Cell Sensor – Aluminum Alloy Weighing: another version this guide coversPhaeton CZL-611RD-20KG Load Cell Sensor – Aluminum Alloy Weighing₹130
Phaeton CZL-611RD-3KG Aluminum Alloy Load Cell Sensor: another version this guide coversPhaeton CZL-611RD-3KG Aluminum Alloy Load Cell Sensor₹69
Phaeton CZL-611RD-5KG Aluminum Alloy Load Cell Sensor: another version this guide coversPhaeton CZL-611RD-5KG Aluminum Alloy Load Cell Sensor₹128
Phaeton CZL-635NB 3KG Aluminum Load Cell Sensor: another version this guide coversPhaeton CZL-635NB 3KG Aluminum Load Cell Sensor₹124
Phaeton CZL-701 Load Cell Sensor – 50kg Capacity, Screw-Fastened: another version this guide coversPhaeton CZL-701 Load Cell Sensor – 50kg Capacity, Screw-Fastened₹44
Phaeton CZL-U-700E Load Cell Sensor 50kg Pressed Down – Screw-Fastened: another version this guide coversPhaeton CZL-U-700E Load Cell Sensor 50kg Pressed Down – Screw-Fastened₹44
Alternatives and when to choose them
- HX711 load cell guide: the amplifier in detail.
- Load cell types: bar, S-type and half bridge.
- S-type and industrial load cells: for heavy and hanging loads.
Common mistakes to avoid
- Bolting the cell flat to the base so it cannot bend.
- Loading it against the arrow direction.
- Overloading a small cell, which bends it permanently.
- Skipping calibration with a known weight.
Frequently asked questions
Which capacity should I choose?
Pick about 1.5 times the heaviest load you expect, for example a 5 kg cell for loads up to about 3 kg.
Why does my reading drift over time?
Temperature change and creep cause drift. Let the cell warm up, avoid drafts and re-tare regularly.
Why is my reading negative?
The signal wires are swapped or the cell is loaded against its arrow. Swap A+ and A- or turn the cell over.
Can I use one bar cell for a large platform?
Yes, within its rating, but a stiff platform is needed so the load passes through the cell.
Do I need an HX711?
Yes, or a similar 24-bit amplifier, because the cell's output is only a few millivolts.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.