Component guide · Intermediate · 3 min read
Bimetal Thermostat Switches
KSD9700, KSD301 and KSD302
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
A bimetal thermostat such as the KSD9700, KSD301 or KSD302 is a small snap-action switch that opens or closes at a fixed temperature, with no electronics. Normally-closed (NC) types cut a heater when it overheats. Normally-open (NO) types switch a fan on when it gets hot. They are accurate to a few degrees, so use them for protection and simple control, not precise regulation.
Key specs at a glance
- Trip temperatures
- Fixed values, commonly 40 to 180 °C; the number is printed on the body
- Accuracy
- Typically ±5 °C
- KSD9700
- Small plastic or metal-shell body, about 5 A at 250 V AC
- KSD301 / KSD302
- Ceramic or metal body, 10 to 16 A at 250 V AC
- Contacts
- NC (opens when hot) or NO (closes when hot)
- Reset
- Auto-reset after cooling by a set differential; manual reset types also exist
This part is often wired to 230 V mains. Do all wiring with the plug pulled out, keep mains wires inside a closed box with strain relief, add a fuse, and never touch the board while it is plugged in. If you are new to mains wiring, have an electrician check it before you switch on.
How a bimetal thermostat works
Inside the metal can sits a disc made of two metals bonded together. They expand at different rates, so as the disc heats it suddenly snaps from one curve to the opposite one, pushing a contact open or closed with a click. When it cools by a few degrees (the switching differential) the disc snaps back.
There is no power supply, no amplifier and no firmware, which is why these parts are trusted for overheating protection in kettles, hair dryers, coffee makers and heating pads.
KSD9700 vs KSD301 vs KSD302
All three use the same principle; they differ in body size and current rating.
| Series | Body | Rating (250 V AC) | Typical use |
|---|---|---|---|
| KSD9700 | Small plastic or metal shell, two tabs | About 5 A | Small heaters, fans, power supplies, appliances |
| KSD301 | Ceramic base with metal cap, larger tabs | 10 to 16 A | Water heaters, ovens, heating elements |
| KSD302 | Ceramic base, similar size to KSD301 | 10 A | Space heaters, hot plates |
- KSD9700
- Body:
- Small plastic or metal shell, two tabs
- Rating (250 V AC):
- About 5 A
- Typical use:
- Small heaters, fans, power supplies, appliances
- KSD301
- Body:
- Ceramic base with metal cap, larger tabs
- Rating (250 V AC):
- 10 to 16 A
- Typical use:
- Water heaters, ovens, heating elements
- KSD302
- Body:
- Ceramic base, similar size to KSD301
- Rating (250 V AC):
- 10 A
- Typical use:
- Space heaters, hot plates
NC or NO: which do you need?
conducts when cool and opens at the trip temperature. Wire it in series with a heating element or supply. If the part overheats, the circuit opens and cools down.
open when cool and closes at the trip temperature. Wire it in series with a fan or alarm so it turns on when the equipment gets hot.
The name on the switch says the trip temperature and sometimes the type, for example "KSD9700 85 °C NC 5 A 250 V".
Mounting and wiring
- 1Press the flat face of the metal shell hard against the surface being monitored, with a dab of thermal paste.
- 2Fix it with a screw, clip or high-temperature tape rated above the trip temperature.
- 3Connect the two tabs in series with the load using insulated crimp terminals.
- 4Keep the load current below the contact rating, with extra margin for motors and heaters that surge at switch-on.
Mains wiring can kill. Use insulated terminals, fuses and an enclosure, and only work on mains circuits if you are qualified.
Limits and alternatives
A bimetal switch has a fixed trip point and a wide differential, so it cannot hold a precise temperature. For adjustable control use a thermistor or DS18B20 with a microcontroller, or a ready-made temperature controller. For one-time safety cutoffs in appliances, use a thermal fuse, which opens once and must be replaced.
Common mistakes to avoid
- Choosing NO when you needed NC, so the heater never switches off.
- Exceeding the rated current with a motor or heater inrush.
- Using it as a precision thermostat.
- Holding it loosely so it reads air temperature, not the surface.
- Forgetting insulation on exposed tabs at mains voltage.
Frequently asked questions
What does NC mean on a thermostat?
Normally closed: the contacts conduct when cool and open when the part reaches its rated temperature.
Can I adjust the trip temperature?
No. The value is fixed at manufacture. Buy the rating you need.
How accurate are KSD9700 switches?
Typically within ±5 °C, with a few degrees of reset hysteresis.
Can I use it with a 12 V fan?
Yes, if the current is below the rating. DC loads are harder on contacts than AC, so keep current low.
What is the difference from a thermal fuse?
A thermostat resets itself. A thermal fuse opens once and stays open.
Which side is the sensing face?
The flat metal face of the can. Mount that against the hot surface.
Parts for this guide
Terms in this guide
Projects that use it
Put this into practice: 1 step-by-step build in our project library uses parts from this guide.
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.