Component guide · Intermediate · 3 min read
Temperature Controllers, Thermocouples and Probes (W1209, MAX6675)
By Geekobot Learning Team · Updated 24 Oct 2026
On this page
A temperature controller reads a probe and switches a heater, cooler or fan to hold a set point. Standalone boards such as the W1209 use an NTC probe and a relay, with hysteresis to prevent rapid switching. For high temperatures, thermocouples read by a MAX6675 or MAX31855 measure hundreds of degrees, and PT100 RTDs give precise industrial readings. For steady control, an Arduino or PID controller drives an SSR.
Key specs at a glance
- W1209
- 12 V thermostat, NTC 10 kΩ probe, about −50 to 110 °C, relay output
- K-type thermocouple
- About −200 to over 1000 °C (probe dependent)
- MAX6675
- K-type, 0 to 1024 °C, 0.25 °C steps, SPI
- MAX31855
- K-type, wider range, cold-junction compensation, SPI, 3.3 V
- PT100 / MAX31865
- Platinum RTD, accurate, 2/3/4-wire
- PID controllers
- Panel units (REX-C100 style) with SSR or relay output
This part is often wired to 230 V mains. Do all wiring with the plug pulled out, keep mains wires inside a closed box with strain relief, add a fuse, and never touch the board while it is plugged in. If you are new to mains wiring, have an electrician check it before you switch on.
Choosing the probe
| Probe | Range | Accuracy | Use |
|---|---|---|---|
| NTC thermistor | About −40 to 125 °C | Good near calibration point | Thermostats, battery packs |
| DS18B20 | −55 to 125 °C | ±0.5 °C typical | Liquids, rooms; see DS18B20 |
| K-type thermocouple | Up to about 1000 °C+ | ±2 °C typical | Ovens, kilns, hot plates |
| PT100 RTD | −200 to 600 °C | High | Industry, process control |
- NTC thermistor
- Range:
- About −40 to 125 °C
- Accuracy:
- Good near calibration point
- Use:
- Thermostats, battery packs
- DS18B20
- Range:
- −55 to 125 °C
- Accuracy:
- ±0.5 °C typical
- Use:
- Liquids, rooms; see DS18B20
- K-type thermocouple
- Range:
- Up to about 1000 °C+
- Accuracy:
- ±2 °C typical
- Use:
- Ovens, kilns, hot plates
- PT100 RTD
- Range:
- −200 to 600 °C
- Accuracy:
- High
- Use:
- Industry, process control
Using a W1209 thermostat
Power it from 12 V and place the probe where you want to measure. Connect the load through the relay's contacts, within the relay rating; for heaters above a few amps, switch a larger relay or SSR instead.
Set the target with the SET button and up/down keys. Menu options set heating or cooling mode (P0), the hysteresis or back-lash (P1) and limits. A hysteresis of 1 to 2 °C stops the relay clicking on and off around the set point. It is a simple thermostat for incubators, Peltier coolers, fermentation boxes and reptile heaters.
Thermocouples and PID with Arduino
A thermocouple produces a few microvolts per degree, so it needs an amplifier with cold-junction compensation such as the MAX6675 or MAX31855, read over SPI. Keep thermocouple wires away from mains and motor wiring, and use thermocouple extension wire, not copper, if you lengthen it.
To hold a temperature steadily, use PID control: a PID library adjusts the heater's on-time through an SSR, using slow time-proportioning (a window of a few seconds) for AC heaters. Always add an independent over-temperature cut-out such as a thermal fuse, because software can fail with the heater on.
Try it: Heating time and heater power calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Switching a large heater directly through the W1209's small relay.
- Zero hysteresis, so the relay chatters.
- Extending a thermocouple with copper wire.
- No independent thermal cut-out on a heater.
- Probe not touching the thing you want to control.
Frequently asked questions
How do I set the W1209 hysteresis?
Hold SET to enter the menu, choose P1 and set the value, typically 1 to 2 °C.
MAX6675 or MAX31855?
MAX31855 has a wider range and 3.3 V operation; the MAX6675 is simpler and 0 to 1024 °C only.
What probe for an oven?
A K-type thermocouple or a PT100 rated for the temperature.
Do I need PID control?
For stable temperature with little overshoot, yes. A simple thermostat is fine for incubators and fans.
Can I use the W1209 for cooling?
Yes. Set P0 to cooling mode (C) and it switches on above the set point.
Parts for this guide
Terms in this guide
Projects that use it
Put this into practice: 21 step-by-step builds in our project library use parts from this guide.
Keep learning
Sources
- Maxim MAX6675, MAX31855 and MAX31865 datasheets
- W1209 thermostat module manual
- IEC 60584 thermocouple tables
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.