Figaro TGS sensors are high-quality metal-oxide gas sensors used in commercial gas alarms. TGS2600 and TGS2602 detect air contaminants and VOCs, TGS2610 detects LP gas, TGS2611 methane and natural gas, TGS3870 methane and CO with a pulsed heater, and TGS6812 hydrogen, methane and LPG with a catalytic element. LPM2610 and NGM2611 modules are factory calibrated.
Key specs at a glance
- Heater
- 5 V, about 40 to 56 mA (TGS26xx)
- Circuit
- Load resistor in series with the sensor, 5 V supply
- TGS2610 / 2611
- LP gas / methane, about 500 to 10,000 ppm
- TGS2600 / 2602
- Air contaminants, VOC, odour
- TGS3870
- Pulsed heater, battery-friendly CO and methane
- Modules
- Calibrated analog output (LPM2610, NGM2611)
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Figaro Engineering TGS 2600 Air Quality Sensor – MOS Type, TO-5 Metal Can₹479
Option 2Figaro Engineering TGS2602 Air Quality / VOC Sensor – MOS Metal-Oxide Semiconductor₹1,509
Option 3Figaro Engineering TGS2610-C00 LP Gas Sensor – TO-5 Metal Can₹499
Option 4Figaro Engineering TGS2611-C00 Methane & Natural Gas Sensor – TO-5 Metal Can₹1,129
Option 5Figaro Engineering TGS3870-F00 Methane/Carbon Monoxide Sensor – MOS Micro-Bead₹2,049
Option 6Figaro Engineering TGS6812-D00 Hydrogen/Methane/LPG Gas Sensor₹2,259
What the Figaro TGS gas sensors and modules is
Figaro TGS gas sensors are metal-oxide sensors whose resistance falls when gases such as LPG, methane, CO, alcohol or VOCs are present, sold as bare sensors and modules.
Figaro sensors are more stable and use less heater power than MQ sensors, but they are read the same way: measure Rs through a load resistor and compare it to the clean-air value.
The TGS3870 and TGS6812 need special heater timing or bridge circuits. Follow Figaro's application notes for them.
Figaro TGS gas sensors and modules pinout
The pins on the Figaro TGS gas sensors and modules and what each one does.
| Pin | Function |
|---|---|
| Pin 1, 4 | Heater (TGS26xx) |
| Pin 2 | Sensor |
| Pin 3 | Sensor |
| Modules | VCC, GND, analog out |
- Pin 1, 4
- Heater (TGS26xx)
- Pin 2
- Sensor
- Pin 3
- Sensor
- Modules
- VCC, GND, analog out
Wiring the Figaro TGS gas sensors and modules
Connect the Figaro TGS gas sensors and modules like this.
| Figaro TGS gas sensors and modules pin | Arduino Uno | ESP32 |
|---|---|---|
| Heater | 5 V across pins 1 and 4 | 5 V across pins 1 and 4 |
| Sensor pin 2 | 5 V | 5 V |
| Sensor pin 3 | A0 and load resistor to GND | GPIO 34 via divider, load resistor to GND |
| Load resistor | About 10 k (check datasheet) | Same |
- Heater
- Arduino Uno:
- 5 V across pins 1 and 4
- ESP32:
- 5 V across pins 1 and 4
- Sensor pin 2
- Arduino Uno:
- 5 V
- ESP32:
- 5 V
- Sensor pin 3
- Arduino Uno:
- A0 and load resistor to GND
- ESP32:
- GPIO 34 via divider, load resistor to GND
- Load resistor
- Arduino Uno:
- About 10 k (check datasheet)
- ESP32:
- Same
Example code
A minimal sketch to check the part works.
const float RL = 10.0; // load resistor on the module, kilo-ohms (check yours)
float R0 = 10.0; // sensor resistance in clean air, set by calibration
float rs() {
long sum = 0;
for (int i = 0; i < 32; i++) sum += analogRead(A0);
float v = sum / 32.0 * 5.0 / 1023.0;
return RL * (5.0 - v) / v;
}
void setup() {
Serial.begin(115200);
delay(120000); // let the heater warm up (much longer for the first use)
R0 = rs(); // calibrate in clean air
}
void loop() {
float ratio = rs() / R0; // look up ppm from the datasheet curve for your gas
Serial.print("Rs/R0 = "); Serial.println(ratio, 3);
delay(1000);
}Setup and tuning
feed the rated heater voltage (often 5 V); the heater draws tens of mA.
read the sensor through a load resistor in a divider and measure the voltage.
let it run 24 to 48 hours on first use and a few minutes each start.
record the clean-air resistance (R0) and use the datasheet Rs/R0 curve.
set thresholds from your calibration, not from raw ADC counts.
What you need
Shop this list12 of 13 found in our store · ₹11,511
Figaro Engineering TGS 2600 Air Quality Sensor – MOS Type, TO-5 Metal Can: the part this guide coversFigaro Engineering TGS 2600 Air Quality Sensor – MOS Type, TO-5 Metal Can₹479
Figaro Engineering TGS2602 Air Quality / VOC Sensor – MOS Metal-Oxide Semiconductor: another version this guide coversFigaro Engineering TGS2602 Air Quality / VOC Sensor – MOS Metal-Oxide Semiconductor₹1,509
Figaro Engineering TGS2610-C00 LP Gas Sensor – TO-5 Metal Can: another version this guide coversFigaro Engineering TGS2610-C00 LP Gas Sensor – TO-5 Metal Can₹499
Figaro Engineering TGS2611-C00 Methane & Natural Gas Sensor – TO-5 Metal Can: another version this guide coversFigaro Engineering TGS2611-C00 Methane & Natural Gas Sensor – TO-5 Metal Can₹1,129
Figaro Engineering TGS3870-F00 Methane/Carbon Monoxide Sensor – MOS Micro-Bead: another version this guide coversFigaro Engineering TGS3870-F00 Methane/Carbon Monoxide Sensor – MOS Micro-Bead₹2,049
Figaro Engineering TGS6812-D00 Hydrogen/Methane/LPG Gas Sensor: another version this guide coversFigaro Engineering TGS6812-D00 Hydrogen/Methane/LPG Gas Sensor₹2,259
Figaro Engineering LPM2610-D09 Butane and Propane Gas Sensor Module: another version this guide coversFigaro Engineering LPM2610-D09 Butane and Propane Gas Sensor Module₹1,249
Figaro Engineering NGM2611-E13 Methane Sensor Module – Factory Calibrated: another version this guide coversFigaro Engineering NGM2611-E13 Methane Sensor Module – Factory Calibrated₹1,649- Uno R3 development board: the controller used in the wiring tableFind this part
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389
ADS1115 16-bit 4-channel ADC module: to read small sensor voltages accuratelyADS1115 16-Bit 4-Channel ADC Module₹199
Buzzer module 3.3-5 V: for an audible alarmBuzzer Module 3.3–5V₹27
5 V relay module with optocoupler: to switch a fan or alarm5V Relay Module with Optocoupler₹74
Alternatives and when to choose them
- MQ gas sensors: cheaper, more power.
- Catalytic combustible sensors: for LEL measurement.
- DFRobot Fermion MEMS: very low power.
Common mistakes to avoid
- Reading the sensor before it has warmed up.
- Trusting raw ADC values as ppm.
- Running the heater from a GPIO pin.
- Using the sensor as a certified life-safety alarm.
Frequently asked questions
Why do readings drift at first?
New sensors need a burn-in of a day or more before readings settle.
Can a TGS sensor give exact ppm values?
Only roughly. Accurate ppm needs calibration with known gas.
Which TGS sensor detects LPG?
The TGS2610 is made for LPG; check the datasheet for each gas.
Does humidity affect readings?
Yes. Temperature and humidity change the resistance, so compensate for them.
Can I power the heater from an Arduino pin?
No. Use the 5 V rail or a transistor, because the heater draws too much current.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.