Component guide · Advanced · 4 min read
Industrial Lux and PAR Light Sensors

Winsen WIN-SN-LUX RS485, 4-20mA and 0-10V, FirstRate FST100-2003, DFRobot RS485 Lux and PAR Sensors and IP68 I2C Light Sensor
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
These sealed light sensors measure illuminance in lux for buildings, streets and solar sites, or PAR for plant growth, and send it to a PLC or data logger. Winsen WIN-SN-LUX models come with RS485 Modbus, 4-20mA or 0-10V outputs in 65,000 or 200,000 lux ranges. The DFRobot PAR sensor measures plant-useful light from 400 to 700 nm in µmol/m²/s.
Key specs at a glance
- Range
- 0-65,535 lux or 0-200,000 lux
- PAR
- 400-700 nm, µmol/m²/s
- Outputs
- RS485 Modbus RTU, 4-20mA or 0-10V
- Supply
- Usually 10-30V DC
- Housing
- IP65 to IP68
- I2C option
- DFRobot IP68 sensor for microcontrollers
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Winsen WIN-SN-LUX-M Lux Sensor (0-65,535 LUX) – Modbus RS485₹5,637
Option 2Winsen WIN-SN-LUX-M(200k) Lux Sensor Module – 0-200k Lux Range, Modbus RS485₹6,817
Option 3WIN-SN-LUX-AO(65k) Lux Sensor – 0-65k Lux Range, 4-20mA Analog Output₹6,913
Option 4Winsen WIN-SN-LUX-AO(65k) Lux Sensor Module – 0-65k Range, 0-10V Analog Output₹6,948
Option 5Winsen WIN-SN-LUX-AO(200k) Lux Sensor with Range 0-200k Lux & 0-10V Analog Output₹7,211
Option 6Winsen WIN-SN-LUX-AO(200k) Lux Sensor Module – 0-200k Lux Range, 4-20mA Analog Output₹7,211
What the Industrial lux and PAR light sensors (RS485, 4-20mA, 0-10V) is
Industrial lux and PAR sensors measure light for buildings, greenhouses and plant growth, with lux for human lighting and PAR (µmol/m²/s) for photosynthesis.
Pick 200,000 lux models for full sunlight outdoors and 65,000 lux models for indoor or shaded use. Use 4-20mA for long cable runs into a PLC, 0-10V for building controllers, and RS485 when several sensors share one cable.
For greenhouses and grow rooms, PAR is more useful than lux because it counts the light plants actually use. Mount sensors level, away from shadows and reflections, and keep the dome clean.
Industrial lux and PAR light sensors (RS485, 4-20mA, 0-10V) pinout
The pins on the Industrial lux and PAR light sensors (RS485, 4-20mA, 0-10V) and what each one does.
| Pin | Function |
|---|---|
| Brown or red | +V 10-30V |
| Black | 0V |
| Yellow / A | RS485 A or signal out |
| Blue / B | RS485 B |
| Shield | Earth at one end |
- Brown or red
- +V 10-30V
- Black
- 0V
- Yellow / A
- RS485 A or signal out
- Blue / B
- RS485 B
- Shield
- Earth at one end
Wiring the Industrial lux and PAR light sensors (RS485, 4-20mA, 0-10V)
4-20mA sensors are usually 2-wire loops; check the manual for loop wiring.
| Industrial lux and PAR light sensors (RS485, 4-20mA, 0-10V) pin | Connection | Note |
|---|---|---|
| +V | 24V supply | Check label |
| 0V | Supply 0V | Common |
| A / B | USB-RS485 converter | Modbus models |
| Signal | PLC analog input | 4-20mA or 0-10V models |
- +V
- Connection:
- 24V supply
- Note:
- Check label
- 0V
- Connection:
- Supply 0V
- Note:
- Common
- A / B
- Connection:
- USB-RS485 converter
- Note:
- Modbus models
- Signal
- Connection:
- PLC analog input
- Note:
- 4-20mA or 0-10V models
Example code
Register layout differs by maker. Check the Modbus table: some sensors give lux in one register, others split it over two.
# pip install minimalmodbus
import minimalmodbus, time
s = minimalmodbus.Instrument("/dev/ttyUSB0", 1)
s.serial.baudrate = 9600 # check the sensor manual (often 4800 or 9600)
s.serial.timeout = 1
while True:
hi = s.read_register(0) # many lux sensors use two registers for large values
lo = s.read_register(1)
lux = (hi << 16) | lo
print("Lux:", lux)
time.sleep(2)Setup and tuning
use lux sensors for room and street lighting, and PAR sensors for plants.
most give RS485 Modbus, 4 to 20 mA or 0 to 5 V outputs.
connect power (often 12 to 24 V) and the output to a PLC, logger or ADC.
keep the dome level, clean and free of shade.
check against a reference meter once a year.
What you need
Shop this list10 of 12 found in our store · ₹56,777
Winsen WIN-SN-LUX-M Lux Sensor (0-65,535 LUX) – Modbus RS485: the part this guide coversWinsen WIN-SN-LUX-M Lux Sensor (0-65,535 LUX) – Modbus RS485₹5,637
Winsen WIN-SN-LUX-M(200k) Lux Sensor Module – 0-200k Lux Range, Modbus RS485: another version this guide coversWinsen WIN-SN-LUX-M(200k) Lux Sensor Module – 0-200k Lux Range, Modbus RS485₹6,817
WIN-SN-LUX-AO(65k) Lux Sensor – 0-65k Lux Range, 4-20mA Analog Output: another version this guide coversWIN-SN-LUX-AO(65k) Lux Sensor – 0-65k Lux Range, 4-20mA Analog Output₹6,913
Winsen WIN-SN-LUX-AO(65k) Lux Sensor Module – 0-65k Range, 0-10V Analog Output: another version this guide coversWinsen WIN-SN-LUX-AO(65k) Lux Sensor Module – 0-65k Range, 0-10V Analog Output₹6,948
Winsen WIN-SN-LUX-AO(200k) Lux Sensor with Range 0-200k Lux & 0-10V Analog Output: another version this guide coversWinsen WIN-SN-LUX-AO(200k) Lux Sensor with Range 0-200k Lux & 0-10V Analog Output₹7,211
Winsen WIN-SN-LUX-AO(200k) Lux Sensor Module – 0-200k Lux Range, 4-20mA Analog Output: another version this guide coversWinsen WIN-SN-LUX-AO(200k) Lux Sensor Module – 0-200k Lux Range, 4-20mA Analog Output₹7,211
FirstRate FST100-2003 Illuminance Transmitter, 0-65535 Lux, RS485 Modbus, 1m Cable: another version this guide coversFirstRate FST100-2003 Illuminance Transmitter, 0-65535 Lux, RS485 Modbus, 1m Cable₹6,339
DFRobot RS485 Waterproof Ambient Light Sensor (0-200,000 Lux) – IP68 Submersible, Modbus-RTU: another version this guide coversDFRobot RS485 Waterproof Ambient Light Sensor (0-200,000 Lux) – IP68 Submersible, Modbus-RTU₹1,259
DFRobot RS485 Photosynthetically Active Radiation (PAR) Sensor (400-700nm) – IP67 Aluminium Alloy: another version this guide coversDFRobot RS485 Photosynthetically Active Radiation (PAR) Sensor (400-700nm) – IP67 Aluminium Alloy₹7,349
DFRobot Gravity IP68 I2C Waterproof Ambient Light Sensor (1–65535 lx): another version this guide coversDFRobot Gravity IP68 I2C Waterproof Ambient Light Sensor (1–65535 lx)₹1,093- USB to RS485 converter: to read Modbus sensors from a PCFind this part
- 24V switching power supply board: to power 12-24V industrial sensors on the benchFind this part
Alternatives and when to choose them
- Ambient light and lux sensors: I2C sensors for boards.
- RS485 water quality sensors: same Modbus wiring.
- 4-20mA signal conditioners: read loops with a microcontroller.
Common mistakes to avoid
- Using lux to judge plant lighting.
- Mounting the sensor tilted.
- Leaving the dome dirty.
- Feeding 0-10 V into a 3.3 V pin.
Frequently asked questions
What is the difference between lux and PAR?
Lux weights light to human eyes; PAR counts photons plants use.
Can I convert lux to PAR?
Only roughly, for a known light source.
Which output should I choose?
RS485 for several sensors, 4 to 20 mA for long cables.
Why are readings too low?
Dust on the dome or shade; clean and reposition it.
Can I read it with Arduino?
Yes, through an RS485 module or analog input.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.