Component guide · Intermediate · 3 min read
MAX31850K and CT1780 1-Wire Thermocouple Amplifiers, DFRobot I2C

and Grove High Temperature Sensors
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
These modules make a K-type thermocouple easy to read without SPI. The MAX31850K (Seeed Grove) and CT1780 (DFRobot) speak 1-Wire like the DS18B20, so several probes can share one pin. The DFRobot Gravity high temperature sensor reads up to 800 degrees C over I2C, and the Grove High Temperature Sensor gives an analog voltage with its own cold-junction thermistor.
Key specs at a glance
- Probe
- K-type
- Interface
- 1-Wire (MAX31850K, CT1780), I2C (DFRobot), analog (Grove high temp)
- Range
- About -270 to 1372 degrees C chip range; probe limits apply (800 degrees C on the DFRobot kit)
- Resolution
- 0.25 degrees C (MAX31850K, CT1780)
- Supply
- 3.3 to 5 V
- Bus
- Unique 64-bit ID per 1-Wire chip
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Seeed Studio Grove 1-Wire Thermocouple Amplifier (MAX31850K) – K-Type, 3.3V/5V₹1,589
Option 2DFRobot Gravity CT1780 1-Wire K-Type Thermocouple Amplifier Module (-270℃ to +1372℃) w/ Probe & Cable₹2,049
Option 3DFRobot Gravity I2C High Temperature Sensor (K-Type, 800°C) – Module & 1.5m Probe₹1,879
Option 4Seeed Studio Grove High Temperature Sensor Module – K-Type Thermocouple, 3.3-5V, 1m Cable₹1,339
What the MAX31850K, CT1780 and Grove thermocouple modules is
MAX31850K and CT1780 thermocouple modules convert a K-type thermocouple into a 1-Wire digital reading, so several thermocouples can share one data pin.
On 1-Wire you can hang several thermocouple boards and DS18B20s on one GPIO with a single 4.7 k pull-up. The MAX31850K also has address pins so you can tell which board is which.
The analog Grove board needs code that adds the thermistor reading back, so use the Seeed example rather than a plain analogRead.
MAX31850K, CT1780 and Grove thermocouple modules pinout
The pins on the MAX31850K, CT1780 and Grove thermocouple modules and what each one does.
| Pin | Function |
|---|---|
| VCC | 3.3 to 5 V |
| GND | Ground |
| DQ / SIG | 1-Wire data or analog out |
| SDA / SCL | I2C (DFRobot) |
| T+ / T- | K-type probe |
- VCC
- 3.3 to 5 V
- GND
- Ground
- DQ / SIG
- 1-Wire data or analog out
- SDA / SCL
- I2C (DFRobot)
- T+ / T-
- K-type probe
Wiring the MAX31850K, CT1780 and Grove thermocouple modules
Grove boards already include the pull-up. Do not add a second one if several share a bus; one per bus is enough.
| MAX31850K, CT1780 and Grove thermocouple modules pin | Arduino Uno | ESP32 |
|---|---|---|
| VCC | 5 V | 3.3 V |
| GND | GND | GND |
| DQ (1-Wire) | D2 with 4.7 k to VCC | GPIO 4 with 4.7 k to 3.3 V |
| SDA / SCL (DFRobot) | A4 / A5 | GPIO 21 / 22 |
- VCC
- Arduino Uno:
- 5 V
- ESP32:
- 3.3 V
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- DQ (1-Wire)
- Arduino Uno:
- D2 with 4.7 k to VCC
- ESP32:
- GPIO 4 with 4.7 k to 3.3 V
- SDA / SCL (DFRobot)
- Arduino Uno:
- A4 / A5
- ESP32:
- GPIO 21 / 22
Example code
The CT1780 uses DFRobot's own library and example; the scratchpad layout differs from the DS18B20.
#include <OneWire.h>
#include <DallasTemperature.h> // reads MAX31850 family too
OneWire bus(2);
DallasTemperature probes(&bus);
void setup() { Serial.begin(115200); probes.begin(); }
void loop() {
probes.requestTemperatures();
for (int i = 0; i < probes.getDeviceCount(); i++) {
Serial.print("Probe "); Serial.print(i); Serial.print(": ");
Serial.print(probes.getTempCByIndex(i), 2); Serial.println(" C");
}
delay(1000);
}Setup and tuning
VCC 3.3 V, GND and DQ to a digital pin with a 4.7 kΩ pull-up.
use OneWire and DallasTemperature, which support the MAX31850.
each module has a unique 64-bit ID; set AD0 to AD3 for location if needed.
connect K-type polarity correctly; reversed wires read backwards.
use ungrounded thermocouples on metal surfaces.
What you need
Shop this list8 of 9 found in our store · ₹9,058
Seeed Studio Studio Grove 1-Wire Thermocouple Amplifier (MAX31850K) – K-Type, 3.3V/5V: the part this guide coversSeeed Studio Grove 1-Wire Thermocouple Amplifier (MAX31850K) – K-Type, 3.3V/5V₹1,589
DFRobot Gravity CT1780 1-Wire K-Type Thermocouple Amplifier Module (-270℃ to +1372℃) w/ Probe & Cable: another version this guide coversDFRobot Gravity CT1780 1-Wire K-Type Thermocouple Amplifier Module (-270℃ to +1372℃) w/ Probe & Cable₹2,049
DFRobot Gravity I2C High Temperature Sensor (K-Type, 800°C) – Module & 1.5m Probe: another version this guide coversDFRobot Gravity I2C High Temperature Sensor (K-Type, 800°C) – Module & 1.5m Probe₹1,879
Seeed Studio Studio Grove High Temperature Sensor Module – K-Type Thermocouple, 3.3-5V, 1m Cable: another version this guide coversSeeed Studio Grove High Temperature Sensor Module – K-Type Thermocouple, 3.3-5V, 1m Cable₹1,339- Uno R3 development board: the controller used in the wiring tableFind this part
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389
K-type thermocouple probe: a probe to plug inK-Type Thermocouple Probe₹101
Resistor assortment kit (30 values): pull-up and divider resistorsResistor Assortment Kit (30 Values)₹33
DS18B20 waterproof temperature probe (1 m): a simple digital probe to compare againstDS18B20 Waterproof Temperature Sensor Probe w/ 1.8m Cable – 1-Wire Digital Interface₹1,679Closest match, check the specs
Alternatives and when to choose them
- MAX31856 and MCP9600: all thermocouple types.
- MAX6675 module: SPI, lowest cost.
- DS18B20 sensor: the 1-Wire sensor these boards behave like.
Common mistakes to avoid
- Reversing thermocouple polarity.
- Leaving out the pull-up.
- Using grounded probes on grounded metal.
- Running long unshielded cables.
Frequently asked questions
Can several MAX31850 modules share one pin?
Yes. 1-Wire lets many sensors share one data pin.
Which library reads the MAX31850?
DallasTemperature with the OneWire library reads it on Arduino, ESP32 and Pico.
Why does temperature go down when heating?
The thermocouple wires are reversed; swap the two leads at the module terminals.
What range does a K-type thermocouple cover?
About -200 to 1350 °C, though the probe sheath and cable often set a lower limit.
Why do I get fault readings?
The thermocouple is open, shorted to ground, or not connected.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.