Component guide · Intermediate · 3 min read
Tiger TK1300B (250 to 1000 kPa), TKJP (40 and 100 kPa)

and TKPS1700 (400 to 1700 kPa) UART and I2C Pressure Sensors
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
Tiger's TK series are calibrated pressure sensors that send readings digitally, so you avoid analog noise and calibration. The TK1300B covers 250 to 1000 kPa gauge, the TKJP 40 and 100 kPa gauge, and the TKPS1700 400 to 1700 kPa absolute with I2C or UART. Use them for compressors, tyre inflators, water systems and pneumatic tools.
Key specs at a glance
- Range
- 40 kPa to 1700 kPa
- Type
- Gauge (TK1300B, TKJP) or absolute (TKPS1700)
- Output
- UART or I2C (check model)
- Supply
- About 3.3 to 5 V
- Accuracy
- About ±1% FS
- Media
- Air and compatible gases or liquids per datasheet
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1Tiger TK1300B 0-500 kPa Gauge Pressure Sensor – Digital UART Output₹57
Option 2Tiger TK1300B 1000KPa Gauge Pressure Sensor – Digital UART Output₹59
Option 3Tiger TK1300B 250KPa Digital Pressure Sensor – UART Output, Gauge Pressure₹59
Option 4Tiger TK1300B 750 kPa Gauge Pressure Sensor – Digital UART Output₹57
Option 5Tiger TKJP040 40 kPa Gauge Pressure Sensor – Digital UART Output₹309
Option 6Tiger TKJP100 100kPa Gauge Pressure Sensor – Digital UART Output₹169
What the Tiger TK1300B, TKJP and TKPS1700 digital pressure sensors is
Tiger TK digital pressure sensors are compact I2C or SPI pressure sensors for air and gas pressure in medical devices, pumps and pneumatic systems.
Each family uses its own frame format; read the datasheet for the byte order and scale. Start by dumping the UART bytes to confirm the baud rate.
Absolute sensors read about 101 kPa at sea level when open; subtract it for gauge pressure.
Tiger TK1300B, TKJP and TKPS1700 digital pressure sensors pinout
The pins on the Tiger TK1300B, TKJP and TKPS1700 digital pressure sensors and what each one does.
| Pin | Function |
|---|---|
| VCC | Supply |
| GND | Ground |
| TX / RX | UART |
| SDA / SCL | I2C (some) |
- VCC
- Supply
- GND
- Ground
- TX / RX
- UART
- SDA / SCL
- I2C (some)
Wiring the Tiger TK1300B, TKJP and TKPS1700 digital pressure sensors
Connect the Tiger TK1300B, TKJP and TKPS1700 digital pressure sensors like this.
| Tiger TK1300B, TKJP and TKPS1700 digital pressure sensors pin | Arduino Uno | ESP32 |
|---|---|---|
| VCC | 5 V | 3V3 or 5 V (check) |
| GND | GND | GND |
| Sensor TX | D10 (SoftwareSerial RX) | GPIO 16 |
| Sensor RX | D11 | GPIO 17 |
- VCC
- Arduino Uno:
- 5 V
- ESP32:
- 3V3 or 5 V (check)
- GND
- Arduino Uno:
- GND
- ESP32:
- GND
- Sensor TX
- Arduino Uno:
- D10 (SoftwareSerial RX)
- ESP32:
- GPIO 16
- Sensor RX
- Arduino Uno:
- D11
- ESP32:
- GPIO 17
Example code
Once the frame is clear, decode pressure with the datasheet's scale.
const long BAUD = 9600; // try 9600, 19200, 115200
void setup() {
Serial.begin(115200);
Serial2.begin(BAUD, SERIAL_8N1, 16, 17);
}
void loop() {
while (Serial2.available()) {
uint8_t b = Serial2.read();
if (b < 0x10) Serial.print('0');
Serial.print(b, HEX); Serial.print(' ');
}
delay(100);
Serial.println();
}Setup and tuning
VCC, GND and I2C or SPI per datasheet.
choose gauge or absolute range for your use.
read raw counts and convert with the datasheet formula.
use with dry, non-corrosive gas unless rated for liquid.
use proper tube fittings.
What you need
Shop this list13 of 13 found in our store · ₹3,003
Tiger TK1300B 0-500 kPa Gauge Pressure Sensor – Digital UART Output: the part this guide coversTiger TK1300B 0-500 kPa Gauge Pressure Sensor – Digital UART Output₹57
Tiger TK1300B 1000KPa Gauge Pressure Sensor – Digital UART Output: another version this guide coversTiger TK1300B 1000KPa Gauge Pressure Sensor – Digital UART Output₹59
Tiger TK1300B 250KPa Digital Pressure Sensor – UART Output, Gauge Pressure: another version this guide coversTiger TK1300B 250KPa Digital Pressure Sensor – UART Output, Gauge Pressure₹59
Tiger TK1300B 750 kPa Gauge Pressure Sensor – Digital UART Output: another version this guide coversTiger TK1300B 750 kPa Gauge Pressure Sensor – Digital UART Output₹57
Tiger TKJP040 40 kPa Gauge Pressure Sensor – Digital UART Output: another version this guide coversTiger TKJP040 40 kPa Gauge Pressure Sensor – Digital UART Output₹309
Tiger TKJP100 100kPa Gauge Pressure Sensor – Digital UART Output: another version this guide coversTiger TKJP100 100kPa Gauge Pressure Sensor – Digital UART Output₹169
Tiger TKPS1700 Pressure Sensor 0-1200 kPa Absolute Pressure – I2C/UART Digital Output: another version this guide coversTiger TKPS1700 Pressure Sensor 0-1200 kPa Absolute Pressure – I2C/UART Digital Output₹129
Tiger TKPS1700 Pressure Sensor 0-1700 kPa Absolute Pressure – I2C Output: another version this guide coversTiger TKPS1700 Pressure Sensor 0-1700 kPa Absolute Pressure – I2C Output₹129
Tiger TKPS1700 Pressure Sensor 0-400 kPa Absolute Pressure – I2C/UART Digital Output: another version this guide coversTiger TKPS1700 Pressure Sensor 0-400 kPa Absolute Pressure – I2C/UART Digital Output₹181
Tiger TKPS1700 Pressure Sensor 0-800 kPa Absolute Pressure – I2C Output: another version this guide coversTiger TKPS1700 Pressure Sensor 0-800 kPa Absolute Pressure – I2C Output₹181
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389
USB to TTL serial converter: to talk to the module from a PCUSB to TTL Serial Converter (CH340G / CP2102 / FT232RL / PL2303)₹85Closest match, check the specs
Stainless steel pressure transducer 0.5 to 4.5 V (1 MPa): a low-cost threaded transducer0.5MPa Stainless Steel Pressure Transducer Sensor – G1/4 Thread, 0.5-4.5V Output₹1,199Closest match, check the specs
Alternatives and when to choose them
- GZP I2C sensors: small PCB sensors.
- Pressure transducers: analog threaded.
- Industrial transmitters: rugged process units.
Common mistakes to avoid
- Wrong range.
- Liquid use without rating.
- 5 V logic.
- No zero calibration.
Frequently asked questions
How do I convert raw counts to pressure?
Apply the transfer function from the datasheet to the raw counts.
Is it gauge or absolute?
The part number shows whether it is gauge or absolute.
Can I use it with water?
Only versions rated for liquid media can be used with water.
Why is the reading offset?
There is a zero offset; read it at zero pressure and subtract it.
Is it 5 V tolerant?
Check the datasheet; many are 3.3 V parts that need level shifting.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.