Shop by category
Shop all componentsComponent codes & values
3 digits ABC: AB × 10^C Ω4 digits ABCD: ABC × 10^D ΩR = decimal point: 4R7 = 4.7 ΩEIA-96 NNL: E96 value N × letter multiplier472 = 47 × 10² = 4.7 kΩ. 1002 = 100 × 10² = 10 kΩ. 4R7 = 4.7 Ω. 01C = 100 × 100 = 10 kΩ (EIA-96).
Surface-mount resistors in 0805 and larger cases carry a short code instead of colour bands. The common 3-digit code gives two digits and a power of ten; 4-digit codes give three digits for 1% parts. An R stands in for the decimal point on low values.
0603 parts are too small for four characters, so 1% values use the EIA-96 system: a two-digit index into the E96 value table plus a letter for the multiplier. 0402 and smaller parts are usually unmarked, so measure them or keep them in labelled tape.
The first two digits are the value and the last is the number of zeros: 10 followed by 3 zeros, so 10,000 Ω or 10 kΩ.
R marks the decimal point, so 4R7 is 4.7 Ω.
That is the EIA-96 code used on 1 % resistors. The two digits pick a value from a table (01 = 100) and the letter is the multiplier (C = ×100), so 01C is 10 kΩ.
3 digits ABC: AB × 10^C Ω; 4 digits ABCD: ABC × 10^D Ω; R = decimal point: 4R7 = 4.7 Ω; EIA-96 NNL: E96 value N × letter multiplier. Here EIA-96 letters is Z ×0.001 · Y/R ×0.01 · X/S ×0.1 · A ×1 and is B/H ×10 · C ×100 · D ×1k · E ×10k · F ×100k.
472 = 47 × 10² = 4.7 kΩ. 1002 = 100 × 10² = 10 kΩ. 4R7 = 4.7 Ω. 01C = 100 × 100 = 10 kΩ (EIA-96).
Results are estimates for design and learning. Check critical designs against the component datasheet. Made by the Geekobot Learning Team. How we write our calculators