Component guide · Intermediate · 4 min read
Flexible Tactile Pressure Arrays

DFRobot Gravity 4x8 and 6x6 Matrix FSR (UART), FS-INS-16Z 16-Zone Insole Film Sensor, Membrane Pressure Sensor Plate and Red Plate with Green Socket
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
Tactile arrays are sheets of many small force cells arranged in a grid, so you can see where pressure lands, not just how much. The DFRobot Gravity 4x8 and 6x6 arrays scan the grid on board and send all cell values over UART, and 4x8 boards can be chained. The FS-INS-16Z is a 16-zone insole film, and the membrane plates are simple press pads.
Key specs at a glance
- DFRobot 4x8
- 32 cells, UART, cascade support
- DFRobot 6x6
- 36 cells, UART
- FS-INS-16Z
- 16 zones, 0.5-10kg each, insole shape
- Membrane plate
- Pressure plate with 3-pin header or green socket
- Supply
- 3.3-5V on DFRobot boards
- Output
- Per-cell values over UART, or one analog per zone
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1DFRobot Gravity 4×8 Flexible Array Tactile Pressure Sensor (UART Cascade Support)₹2,939
Option 2DFRobot Gravity 6×6 Flexible Array Tactile Pressure Sensor (UART Matrix FSR)₹2,939
Option 3FS-INS-16Z Force Sensitive Resistor (0.5kg-10kg) – 16-Zone Flexible Film Sensor₹7,639
Option 4Membrane Pressure Sensor Plate – Red Plate w/ 3-Pin Green Header₹140
Option 5Red Plate for Membrane Pressure Sensor (Green Socket Type)₹156
What the Flexible tactile pressure arrays, 16-zone film and membrane pressure plates is
Flexible tactile pressure arrays are thin sensor mats with a grid of force-sensing points, used to map pressure in grippers, seats, insoles, beds and robot skin.
Use arrays for pressure maps: smart insoles and gait, seat and bed posture, robot skin and touch pads that know where you pressed. Read the DFRobot boards with the UART frame format in the wiki and draw the grid as a heat map on a PC or display.
The FS-INS-16Z has one lead per zone plus a common, so each zone needs its own divider and analog pin, or an analog multiplexer such as a CD74HC4067. Keep the film flat and protect it under a thin layer of foam or fabric.
Flexible tactile pressure arrays, 16-zone film and membrane pressure plates pinout
The pins on the Flexible tactile pressure arrays, 16-zone film and membrane pressure plates and what each one does.
| Pin | Function |
|---|---|
| VCC | 3.3-5V (DFRobot) |
| GND | Ground |
| TX / RX | UART to the controller |
| Zone leads | One per zone on FS-INS-16Z |
| Common | Shared lead on FS-INS-16Z |
- VCC
- 3.3-5V (DFRobot)
- GND
- Ground
- TX / RX
- UART to the controller
- Zone leads
- One per zone on FS-INS-16Z
- Common
- Shared lead on FS-INS-16Z
Wiring the Flexible tactile pressure arrays, 16-zone film and membrane pressure plates
Baud rate and frame format are in the DFRobot wiki for each board; match them exactly.
| Flexible tactile pressure arrays, 16-zone film and membrane pressure plates pin | Connection | Note |
|---|---|---|
| DFRobot TX | ESP32 GPIO16 (RX2) | Serial2 |
| DFRobot RX | ESP32 GPIO17 (TX2) | Serial2 |
| VCC / GND | 3.3V / GND | Common ground |
| FS-INS-16Z zones | CD74HC4067 inputs | 10k pull-down each |
- DFRobot TX
- Connection:
- ESP32 GPIO16 (RX2)
- Note:
- Serial2
- DFRobot RX
- Connection:
- ESP32 GPIO17 (TX2)
- Note:
- Serial2
- VCC / GND
- Connection:
- 3.3V / GND
- Note:
- Common ground
- FS-INS-16Z zones
- Connection:
- CD74HC4067 inputs
- Note:
- 10k pull-down each
Example code
This shows the raw frames so you can match them to the header and cell layout in the board's wiki, then parse each cell into a grid.
void setup() {
Serial.begin(115200);
Serial2.begin(115200, SERIAL_8N1, 16, 17); // set the array's baud rate
}
void loop() {
while (Serial2.available()) {
byte b = Serial2.read();
if (b < 0x10) Serial.print('0');
Serial.print(b, HEX);
Serial.print(' ');
}
delay(20);
}Setup and tuning
each crossing of a row and a column is a small force-sensing resistor whose resistance falls as you press.
drive one row at a time high and read every column through an analog multiplexer such as the CD74HC4067.
put a resistor (1 to 10 kΩ) from each column to ground so resistance becomes a voltage.
ground the unused rows or use the vendor scan board to stop false points between pressed cells.
press known weights on a few cells and fit a curve; readings are not linear.
keep the mat flat, support the connector tail and never bend it sharply.
What you need
Shop this list8 of 8 found in our store · ₹14,336
DFRobot Gravity 4×8 Flexible Array Tactile Pressure Sensor (UART Cascade Support): the part this guide coversDFRobot Gravity 4×8 Flexible Array Tactile Pressure Sensor (UART Cascade Support)₹2,939
DFRobot Gravity 6×6 Flexible Array Tactile Pressure Sensor (UART Matrix FSR): another version this guide coversDFRobot Gravity 6×6 Flexible Array Tactile Pressure Sensor (UART Matrix FSR)₹2,939
FS-INS-16Z Force Sensitive Resistor (0.5kg-10kg) – 16-Zone Flexible Film Sensor: another version this guide coversFS-INS-16Z Force Sensitive Resistor (0.5kg-10kg) – 16-Zone Flexible Film Sensor₹7,639
Generic Membrane Pressure Sensor Plate – Red Plate w/ 3-Pin Green Header: another version this guide coversMembrane Pressure Sensor Plate – Red Plate w/ 3-Pin Green Header₹140
Generic Red Plate for Membrane Pressure Sensor (Green Socket Type): another version this guide coversRed Plate for Membrane Pressure Sensor (Green Socket Type)₹156
ESP32-WROOM-32 38-pin development board: for Wi-Fi logging and dashboardsESP32-WROOM-32 38-Pin Development Board₹389
Dupont jumper wires: for the connectionsDupont Jumper Wires (40 pcs)₹49Closest match, check the specs
USB to TTL serial converter: to talk to the module from a PCUSB to TTL Serial Converter (CH340G / CP2102 / FT232RL / PL2303)₹85Closest match, check the specs
Alternatives and when to choose them
- RP and RFP602 thin-film sensors: single pads.
- Tekscan FlexiForce sensors: one repeatable cell.
- Force sensitive resistor guide: basics.
Common mistakes to avoid
- Bending or creasing the connector tail.
- Leaving unused rows floating, which causes ghost points.
- Treating raw readings as calibrated force.
- Cutting the mat to fit.
Frequently asked questions
How do I read a tactile pressure array with Arduino?
Drive one row at a time, read the columns through a multiplexer, then move to the next row.
Why do pressed points appear in other cells?
That is ghosting from current paths through other cells; ground the unused rows or add diodes.
Can the array measure exact force in newtons?
Only roughly. Calibrate each cell with known weights, and expect drift and hysteresis.
How fast can I scan the whole mat?
With a fast ADC, small mats scan at 50 to 100 frames per second; large mats are slower.
Can I cut the mat to a smaller size?
No. Cutting breaks the printed traces, so buy the size you need.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.