Component guide · Beginner · 3 min read
STC-1000, STC-3028 and ZFX-W9002 Temperature and Humidity Controllers

and Hatchery Controller
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
These panel-mount controllers run fridges, incubators, brewing and mushroom rooms without programming. The STC-1000 has separate heating and cooling relays and a 10k probe. The STC-3028 and ZFX-W9002 add a humidity sensor and a second relay for a humidifier or fan. The hatchery controller adds egg-turning and alarm outputs.
Key specs at a glance
- Supply
- 220 V AC (12 V versions of ZFX-W9002 exist)
- Temperature range
- About -50 to 99 degrees C (STC-1000)
- Humidity range
- About 1 to 99% RH (STC-3028, ZFX-W9002)
- Outputs
- Relays, about 10 A each
- Cut-out
- About 71 x 29 mm panel hole (STC-1000)
- Settings
- Setpoint, hysteresis, compressor delay, calibration
This part is often wired to 230 V mains. Do all wiring with the plug pulled out, keep mains wires inside a closed box with strain relief, add a fuse, and never touch the board while it is plugged in. If you are new to mains wiring, have an electrician check it before you switch on.
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1STC-1000 Digital Temperature Controller, 220V AC₹328
Option 2STC-3028 Digital Temperature and Humidity Controller₹741
Option 3ZFX-W9002 Smart Thermostat Temperature Humidity Controller 220V AC – 0-110°C Range, 4-Digit Display₹1,359
Option 4ZFX-W9002 Smart Thermostat Temperature Humidity Controller 12V₹1,322
Option 5Automatic Hatchery Machine Temperature Controller – AC160-240V, 7 Output Channels, w/ Temp & Humidity Sensors₹2,609
What the STC-1000, STC-3028 and ZFX-W9002 controllers is
The STC-1000 is a panel-mount digital thermostat with an NTC probe and two relays, one for heating and one for cooling, used for fermenters, incubators and fridges.
On the STC-1000: F1 sets the target, F2 the hysteresis, F3 the compressor delay and F4 the probe offset. Heating relay on means below target; cooling relay on means above target.
Humidity controllers can be set to humidify (relay on when dry) or dehumidify (relay on when damp).
STC-1000, STC-3028 and ZFX-W9002 controllers pinout
The pins on the STC-1000, STC-3028 and ZFX-W9002 controllers and what each one does.
| Pin | Function |
|---|---|
| Power terminals | AC supply |
| Heat relay | Heater or humidifier |
| Cool relay | Compressor or fan |
| Sensor | NTC or combined T and RH probe |
- Power terminals
- AC supply
- Heat relay
- Heater or humidifier
- Cool relay
- Compressor or fan
- Sensor
- NTC or combined T and RH probe
Wiring the STC-1000, STC-3028 and ZFX-W9002 controllers
Mains wiring must be in an earthed, closed enclosure with a fuse. Each relay only switches; it does not supply power, so link live into the common terminal.
| STC-1000, STC-3028 and ZFX-W9002 controllers pin | STC-1000 | STC-3028 / ZFX-W9002 |
|---|---|---|
| L and N | Mains supply | Mains supply |
| Heat relay | Live to heater | Live to humidifier (STC-3028) |
| Cool relay | Live to fridge or fan | Live to fan |
| Probe | Probe terminals | Probe socket |
- L and N
- STC-1000:
- Mains supply
- STC-3028 / ZFX-W9002:
- Mains supply
- Heat relay
- STC-1000:
- Live to heater
- STC-3028 / ZFX-W9002:
- Live to humidifier (STC-3028)
- Cool relay
- STC-1000:
- Live to fridge or fan
- STC-3028 / ZFX-W9002:
- Live to fan
- Probe
- STC-1000:
- Probe terminals
- STC-3028 / ZFX-W9002:
- Probe socket
Example code
A minimal sketch to check the part works.
Hold S for 3 s to enter the menu.
F1 = 18.0 target (degrees C)
F2 = 0.5 hysteresis
F3 = 3 compressor delay in minutes
F4 = 0.0 probe offset
Heat relay -> heat belt, cool relay -> fridge.
Fridge runs above 18.5 C, heat belt runs below 17.5 C.Setup and tuning
check whether yours is the 230 V AC, 110 V or 12 V version before wiring.
wire the heater to the heating relay and the compressor or fan to the cooling relay; mains wiring must be done by a qualified person in an enclosure.
set F1 (temperature) and F2 (hysteresis, such as 0.5 °C).
set F3 to protect fridge compressors from short cycling.
place the NTC probe in the space or liquid you control.
What you need
Shop this list8 of 8 found in our store · ₹7,084
STC-1000 Digital Temperature Controller, 220V AC: the part this guide coversSTC-1000 Digital Temperature Controller, 220V AC₹328
STC-3028 Digital Temperature and Humidity Controller: another version this guide coversSTC-3028 Digital Temperature and Humidity Controller₹741
ZFX-W9002 Smart Thermostat Temperature Humidity Controller 220V AC – 0-110°C Range, 4-Digit Display: another version this guide coversZFX-W9002 Smart Thermostat Temperature Humidity Controller 220V AC – 0-110°C Range, 4-Digit Display₹1,359
ZFX-W9002 Smart Thermostat Temperature Humidity Controller 12V: another version this guide coversZFX-W9002 Smart Thermostat Temperature Humidity Controller 12V₹1,322
Generic Automatic Hatchery Machine Temperature Controller – AC160-240V, 7 Output Channels, w/ Temp & Humidity Sensors: another version this guide coversAutomatic Hatchery Machine Temperature Controller – AC160-240V, 7 Output Channels, w/ Temp & Humidity Sensors₹2,609- 12 V silicone heating pad: a heater to control12V Silicone Heating Pad₹250
Digital multimeter: to check supply and signal voltagesDigital Multimeter₹177
SMPS power supply in metal enclosure (5/12/24 V): a 12 V or 24 V supplySMPS Power Supply, Metal Enclosure (5V / 12V / 24V)₹298Closest match, check the specs
Alternatives and when to choose them
- W1209 and XH-W3001 modules: single relay, low voltage.
- Temperature controllers and probes: PID controllers with SSR output.
- AM2301 humidity sensors: build your own with a microcontroller.
Common mistakes to avoid
- Wiring the wrong supply version.
- Exceeding the relay rating.
- Zero compressor delay.
- Mains wiring outside an enclosure.
Frequently asked questions
How do I set the temperature on an STC-1000?
Hold SET, choose F1, set the value and save.
What does F2 hysteresis do?
It sets how far temperature must drift before the relay switches again.
Can the relays switch a fridge compressor?
Small compressors yes, within the 10 A rating; use a contactor for bigger loads.
Why does the display show EE or HH?
The probe is faulty, disconnected or out of range.
Can I extend the probe cable?
Yes, short extensions work; calibrate with F4 if needed.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.