Component guide · Beginner · 3 min read
W1209, XH-W1219, XH-W1301, W3230 and XH-W3001 Digital Thermostat Modules

Setup and Wiring
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
These are ready-made digital thermostats with an NTC probe, display, buttons and relay. You set a target temperature and the relay switches a heater or cooler on and off around it. The W1209 and XH-W1219 run from 12 V, the W3230 from 12 or 24 V, and the XH-W3001 from 12, 24 or 220 V with a 10 A relay. No programming is needed.
Key specs at a glance
- Supply
- 12 V (W1209, XH-W1219), 12 or 24 V (W3230), 12, 24 or 110 to 220 V (XH-W3001 by model)
- Range
- About -50 to 110 degrees C
- Resolution
- 0.1 degrees C
- Relay
- About 10 A contacts (check the module)
- Probe
- 10k NTC, waterproof
- Modes
- Heating (H) or cooling (C)
This part is often wired to 230 V mains. Do all wiring with the plug pulled out, keep mains wires inside a closed box with strain relief, add a fuse, and never touch the board while it is plugged in. If you are new to mains wiring, have an electrician check it before you switch on.
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 1W1209 Digital Temperature Controller Module, 12V₹150
Option 2XH-W1219 12V Digital Temperature Controller with Waterproof Probe₹188
Option 3W3230 24V DC Digital Temperature Controller₹224
Option 4XH-W3001 Digital Thermostat Controller, 220V 1500W₹141
Option 5XH-W1301 Digital Display Intelligent Thermostat Controller – 50℃~110℃ Range, 0.1℃ Accuracy, 12V DC/AC, 50cm Cable₹249
What the W1209, XH-W1219, W3230 and XH-W3001 thermostat modules is
The W1209 and XH-W3001 are low-cost digital thermostat modules with an NTC probe and relay, used to control heaters or fans in incubators, boxes and fermenters.
Long-press SET to open the menu. On the W1209: P0 selects C (cooling) or H (heating), P1 sets hysteresis, P2 and P3 limit the setpoint range, P4 corrects the probe offset, P5 adds a start delay and P6 sets a high-temperature alarm. The XH-W3001 and W3230 have similar menus with their own codes.
The relay is a dry contact. It switches whatever runs through it, but the 10 A rating assumes a resistive load; derate for motors and compressors.
W1209, XH-W1219, W3230 and XH-W3001 thermostat modules pinout
The pins on the W1209, XH-W1219, W3230 and XH-W3001 thermostat modules and what each one does.
| Pin | Function |
|---|---|
| +12 V / GND | Module supply |
| K0, K1 (relay) | Switched contact |
| NTC | Probe socket |
| SET, +, - | Buttons |
- +12 V / GND
- Module supply
- K0, K1 (relay)
- Switched contact
- NTC
- Probe socket
- SET, +, -
- Buttons
Wiring the W1209, XH-W1219, W3230 and XH-W3001 thermostat modules
For mains loads, use the 220 V XH-W3001 inside a closed box with a fuse, and switch only the live wire. Ask a qualified person if unsure.
| W1209, XH-W1219, W3230 and XH-W3001 thermostat modules pin | 12 V heater | Mains heater (XH-W3001 220 V) |
|---|---|---|
| Module supply | 12 V supply + and - | Mains L and N, through a fuse |
| Relay contact | In series with the heater + lead | In series with the heater live wire |
| Heater return | Heater - to supply - | Heater neutral to mains N |
| Probe | Plug into NTC socket | Plug into NTC socket |
- Module supply
- 12 V heater:
- 12 V supply + and -
- Mains heater (XH-W3001 220 V):
- Mains L and N, through a fuse
- Relay contact
- 12 V heater:
- In series with the heater + lead
- Mains heater (XH-W3001 220 V):
- In series with the heater live wire
- Heater return
- 12 V heater:
- Heater - to supply -
- Mains heater (XH-W3001 220 V):
- Heater neutral to mains N
- Probe
- 12 V heater:
- Plug into NTC socket
- Mains heater (XH-W3001 220 V):
- Plug into NTC socket
Example code
These modules are stand-alone. To log the temperature, add a separate sensor to a microcontroller.
1. Long-press SET for 5 s. Display shows P0.
2. P0 = H (heat: relay on when cold)
3. P1 = 0.5 (hysteresis in degrees C)
4. P4 = 0.0 (probe offset; correct after a check)
5. Press SET to save, wait to exit.
6. Short-press SET, use + / - to set 37.5 (incubator).
Relay turns on below 37.5 and off once the temperature rises 0.5 above it.Setup and tuning
W1209 runs on 12 V DC; XH-W3001 comes in 12 V, 24 V and 230 V versions.
switch loads within the relay rating; mains loads need an enclosure and safe wiring.
set heating (H) or cooling (C) mode.
set the return difference so the relay does not chatter.
place the NTC probe where you control temperature.
What you need
Shop this list9 of 9 found in our store · ₹1,837
W1209 Digital Temperature Controller Module, 12V: the part this guide coversW1209 Digital Temperature Controller Module, 12V₹150
XH-W1219 12V Digital Temperature Controller with Waterproof Probe: another version this guide coversXH-W1219 12V Digital Temperature Controller with Waterproof Probe₹188
W3230 24V DC Digital Temperature Controller: another version this guide coversW3230 24V DC Digital Temperature Controller₹224
XH-W3001 Digital Thermostat Controller, 220V 1500W: another version this guide coversXH-W3001 Digital Thermostat Controller, 220V 1500W₹141
XH-W1301 Digital Display Intelligent Thermostat Controller – 50℃~110℃ Range, 0.1℃ Accuracy, 12V DC/AC, 50cm Cable: another version this guide coversXH-W1301 Digital Display Intelligent Thermostat Controller – 50℃~110℃ Range, 0.1℃ Accuracy, 12V DC/AC, 50cm Cable₹249
SMPS power supply in metal enclosure (5/12/24 V): a 12 V or 24 V supplySMPS Power Supply, Metal Enclosure (5V / 12V / 24V)₹298Closest match, check the specs- 12 V silicone heating pad: a heater to control12V Silicone Heating Pad₹250
12 V relay module: to switch a bigger load from the controller12V Relay Module₹160
Digital multimeter: to check supply and signal voltagesDigital Multimeter₹177
Alternatives and when to choose them
- STC-1000 and ZFX-W9002 controllers: panel-mount with separate heat and cool outputs.
- Temperature controllers and probes: industrial PID controllers.
- Sonoff TH switch: Wi-Fi control.
Common mistakes to avoid
- Wrong supply voltage.
- Overloading the relay.
- Wrong mode.
- Zero hysteresis.
Frequently asked questions
How do I set heating mode on the W1209?
Hold SET, go to P0 and choose H for heating mode.
What is hysteresis on these thermostats?
It is the temperature gap before the relay switches back, which stops rapid clicking.
Can the relay switch mains heaters?
Only small loads within the relay rating, wired inside a safe enclosure.
Why does the display show LLL or HHH?
The probe is unplugged, damaged or outside its range.
Is the W1209 accurate?
About ±0.5 to 1 °C; calibrate with the offset setting.
Parts for this guide
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.