Component guide · Intermediate · 3 min read
40 kHz Ultrasonic Transducers
Open Transmitters, Receivers and Cleaning Transducers
By Geekobot Learning Team · Updated 29 Oct 2026
On this page
An ultrasonic transducer is a ceramic disc that vibrates at one resonant frequency, commonly 40 kHz. Open transmitter and receiver pairs let you build your own range finder or communication link. Drive the transmitter with a square wave at its exact resonance, and amplify the tiny receiver signal. Cleaning transducers of 28, 40 and 68 kHz are power devices that need a proper generator.
Key specs at a glance
- Frequencies
- 25, 28, 40, 68 kHz
- Open pair
- 12x9 mm and 16x12 mm transmitters and receivers
- Drive
- Square wave at resonance; 5 to 20 V for more range
- Receiver
- Needs an amplifier and filter
- Cleaning types
- 60 W stainless transducers for tanks
- Matching
- Transmitter and receiver must share a frequency
Types
Use the right transducer for the job.
| Type | Use | Notes |
|---|---|---|
| 40 kHz open transmitter (T) and receiver (R) | DIY range finders, proximity, communication | Pair them; 16 mm gives more range than 12 mm |
| 25 kHz transmitter | Longer range, lower frequency | Wider beam, lower resolution |
| Closed (waterproof) sensors | Parking sensors and level | See industrial ultrasonic sensors |
| 28/40/68 kHz cleaning transducers | Ultrasonic cleaners | 60 W; needs a generator board and a tank |
- 40 kHz open transmitter (T) and receiver (R)
- Use:
- DIY range finders, proximity, communication
- Notes:
- Pair them; 16 mm gives more range than 12 mm
- 25 kHz transmitter
- Use:
- Longer range, lower frequency
- Notes:
- Wider beam, lower resolution
- Closed (waterproof) sensors
- Use:
- Parking sensors and level
- Notes:
- See industrial ultrasonic sensors
- 28/40/68 kHz cleaning transducers
- Use:
- Ultrasonic cleaners
- Notes:
- 60 W; needs a generator board and a tank
Driving a transmitter
Feed the transmitter a 40 kHz square wave from a timer output, preferably with two inverted signals driving it differentially to double the voltage. A bare microcontroller pin gives short range; a driver such as a MOSFET gate driver or a MAX232-style level converter raises the voltage and range. Send short bursts of eight to ten cycles and then listen; see PWM and the ultrasonic distance tool.
Receiving the echo
The receiver gives millivolts. Amplify it with an op-amp stage, band-pass filter it around 40 kHz and use a comparator to produce a clean pulse; chips such as the CX20106 do this in one package. Time the delay between the burst and the echo to calculate distance. See HC-SR04 for a finished module.
Cleaning transducers
High-power transducers are glued or bolted to the bottom of a tank and driven by a generator at the correct frequency. They get hot and must never run dry. Do not touch the tank while it is running. Lower frequencies (28 kHz) clean heavy dirt; higher frequencies (68 kHz) are gentler on delicate parts.
Tips
- Match the drive frequency to the transducer's marked resonance; a few percent off cuts output sharply.
- Point transmitter and receiver at the target, spaced a few centimetres apart.
- Soft materials such as fabric absorb the echo.
- Temperature changes the speed of sound, so compensate for accurate distance.
Try it: Ultrasonic distance calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Driving at the wrong frequency.
- Using a transmitter and receiver of different frequencies.
- Forgetting to amplify the receiver.
- Running a cleaning transducer dry.
- Ignoring the speed of sound change with temperature.
Frequently asked questions
Can I use the same transducer for TX and RX?
Yes with switching, but separate parts are easier.
Why is my range short?
Drive voltage, frequency match and receiver gain are the usual causes.
Are ultrasonic transducers safe?
Airborne 40 kHz at low power is fine. High-power cleaning transducers need care.
What is the difference between T and R types?
The transmitter is built for output and the receiver for sensitivity.
Can a cleaning transducer run from a microcontroller?
No. It needs a power generator.
Parts for this guide
Calculators
Terms in this guide
Projects that use it
Put this into practice: 21 step-by-step builds in our project library use parts from this guide.
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.