Component guide · Intermediate · 3 min read
LiFePO4 Batteries
Voltages, Charging and When to Use Them
By Geekobot Learning Team · Updated 24 Oct 2026
On this page
LiFePO4 (lithium iron phosphate, LFP) cells run at 3.2 V nominal and charge to 3.65 V, so four in series make a 12.8 V pack that can directly replace a 12 V lead-acid battery. They last thousands of cycles and are far more resistant to thermal runaway than ordinary Li-ion, but they hold less energy per kilogram. Use a charger and BMS made for LiFePO4: Li-ion chargers and BMS boards use the wrong voltages.
Key specs at a glance
- Cell voltage
- 3.2 V nominal, 3.65 V full, 2.5 V empty
- 4S pack
- 12.8 V nominal, 14.6 V full
- Cycle life
- About 2000 to 6000 cycles
- Energy density
- About 90 to 160 Wh/kg (Li-ion 150 to 270)
- Common cells
- 26650, 32650, 32700 cylindrical; prismatic blocks
- Charging
- CC/CV to 3.6 to 3.65 V per cell
A shorted, over-charged or damaged lithium cell can get very hot and catch fire. Use a protection board or BMS, never short the terminals, charge on a non-flammable surface and do not leave a charging pack alone. Throw away cells that are swollen or dented.
LiFePO4 vs Li-ion vs lead-acid
| LiFePO4 | Li-ion (NMC/NCA) | Lead-acid | |
|---|---|---|---|
| Cell voltage | 3.2 V | 3.6 to 3.7 V | 2 V |
| Energy per kg | Medium | High | Low |
| Cycle life | 2000 to 6000 | 300 to 1000 | 200 to 500 |
| Thermal safety | Very stable | Can enter thermal runaway | Stable, but gives off hydrogen when charging |
| Usable capacity | 90 to 100% | 80 to 90% | About 50% |
| Cost per cycle | Low | Medium | High |
| Best for | Solar storage, UPS, boats, robots that run all day | Phones, drones, compact projects | Cheap backup, car starting |
- Cell voltage
- LiFePO4:
- 3.2 V
- Li-ion (NMC/NCA):
- 3.6 to 3.7 V
- Lead-acid:
- 2 V
- Energy per kg
- LiFePO4:
- Medium
- Li-ion (NMC/NCA):
- High
- Lead-acid:
- Low
- Cycle life
- LiFePO4:
- 2000 to 6000
- Li-ion (NMC/NCA):
- 300 to 1000
- Lead-acid:
- 200 to 500
- Thermal safety
- LiFePO4:
- Very stable
- Li-ion (NMC/NCA):
- Can enter thermal runaway
- Lead-acid:
- Stable, but gives off hydrogen when charging
- Usable capacity
- LiFePO4:
- 90 to 100%
- Li-ion (NMC/NCA):
- 80 to 90%
- Lead-acid:
- About 50%
- Cost per cycle
- LiFePO4:
- Low
- Li-ion (NMC/NCA):
- Medium
- Lead-acid:
- High
- Best for
- LiFePO4:
- Solar storage, UPS, boats, robots that run all day
- Li-ion (NMC/NCA):
- Phones, drones, compact projects
- Lead-acid:
- Cheap backup, car starting
Charging LiFePO4 correctly
Charge with constant current, then constant voltage at 3.6 to 3.65 V per cell (14.4 to 14.6 V for a 4S pack), and stop when the current falls to a small fraction. A float voltage is not needed; if a charger has float, set it around 13.5 V for 4S. Do not charge below 0 °C. A Li-ion charger (4.2 V per cell) will overcharge LiFePO4, and a 3.65 V LiFePO4 charger will undercharge Li-ion. Many 12 V solar controllers have a LiFePO4 or 'user' mode; set it before connecting.
BMS and pack building
Use a BMS made for LiFePO4 thresholds (over-charge around 3.65 to 3.75 V, over-discharge around 2.5 V). LiFePO4 cells have a very flat voltage curve between about 10% and 90% charge, so voltage alone is a poor charge gauge; a coulomb counter or smart BMS gives a better reading. Match cell capacities and starting voltages before building a pack, and use a BMS with balancing.
Where LiFePO4 makes sense in projects
that cycle every day for years. See solar power.
replacing lead-acid: CCTV backup, routers, camper electronics, robot platforms.
that run for hours and are charged daily.
one LiFePO4 cell (3.2 V nominal, 3.65 V full) can power a 3.3 V ESP32 or Pico directly without a regulator, which is a neat trick for simple builds; check that 3.65 V is within the board's limit (the ESP32 module's absolute maximum is 3.6 V, so add a diode drop or regulator on a full cell).
For drones or anything where weight matters most, Li-ion or LiPo is still the better choice. See lithium batteries.
Try it: Battery pack calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Charging LiFePO4 with a Li-ion charger set to 4.2 V per cell.
- Using a Li-ion BMS on a LiFePO4 pack.
- Judging charge from voltage in the flat middle of the curve.
- Charging below freezing.
- Feeding a full 3.65 V cell straight into a 3.6 V-max module.
Frequently asked questions
What is the voltage of a LiFePO4 cell?
3.2 V nominal, 3.65 V fully charged and about 2.5 V empty.
Can I charge LiFePO4 with a Li-ion charger?
No. Li-ion chargers go to 4.2 V per cell, which overcharges LiFePO4. Use a charger or controller set to 3.6 to 3.65 V per cell.
Is LiFePO4 safer than Li-ion?
Yes. Its chemistry is far more resistant to thermal runaway, though any battery can be dangerous if shorted or damaged.
Can a 12 V LiFePO4 replace a lead-acid battery?
Usually yes, with a charger or controller that supports LiFePO4. It is lighter and lasts many more cycles.
Why is LiFePO4 heavier than Li-ion for the same capacity?
LiFePO4 stores less energy per kilogram, so a pack with the same watt-hours is larger and heavier.
Parts for this guide
Calculators
Terms in this guide
Keep learning
Sources
- LiFePO4 cell manufacturer datasheets (for example EVE, CATL, Lishen)
- IEC 62619 safety requirements for industrial lithium batteries
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.