Shop by category
Shop all componentsPower, batteries & solar
t (h) = capacity (Ah) ÷ (I × efficiency)C-rate = I ÷ capacity (Ah)A 2000 mAh 18650 on a TP4056 module at 1 A and 85% efficiency: 2 ÷ (1 × 0.85) = 2.35 hours. That is 0.5 C, a normal charge rate.
Charging time is roughly capacity divided by current, plus extra for losses. Lithium chargers use constant current until about 4.2 V, then constant voltage while the current tapers off, which adds the last half hour or so.
Most Li-ion cells are happiest charged at 0.5 C or less. The TP4056 module defaults to 1 A, set by its PROG resistor; for small LiPo cells below 1000 mAh, change that resistor to lower the current.
About 2000 ÷ 1000 ÷ 0.85 ≈ 2.4 hours, since charging is not 100 % efficient and slows near full.
0.5 C is a common safe rate: 1 A for a 2000 mAh cell. Check the datasheet for the maximum.
Li-ion chargers switch to constant voltage near full, so the current tapers off as the cell fills.
t (h) = capacity (Ah) ÷ (I × efficiency); C-rate = I ÷ capacity (Ah).
A 2000 mAh 18650 on a TP4056 module at 1 A and 85% efficiency: 2 ÷ (1 × 0.85) = 2.35 hours. That is 0.5 C, a normal charge rate.
Geekobot builds that use it include DIY 18650 power bank, 18650 charging station with USB output, Cup-full alert for blind and low-vision users and Vibrating kitchen timer with a big knob. Each has the full parts list, wiring and code.
Results are estimates for design and learning. Check critical designs against the component datasheet. Made by the Geekobot Learning Team. How we write our calculators