Cleaning transducers are bolted piezo stacks (Langevin type) that turn 60W of electrical power into strong vibration. Glued under a stainless tank and driven by a matching generator, they make the bubbles that clean parts: 28kHz for heavy dirt, 40kHz general, 68kHz for delicate items. The NU series are sensing transducers: 75kHz for proximity, 200kHz for wind and distance, and 1MHz for flow measurement in liquids.
Key specs at a glance
- Cleaning power
- 60W each, 28, 40 or 68kHz
- Mounting
- Epoxy bonded to tank bottom, about 1 per litre
- Driver
- Matched ultrasonic generator board
- NU75E40TR
- 75kHz, 40mm, proximity
- NU200
- 200kHz, 12 or 18mm, wind and distance
- NU1ME21TR
- 1MHz, 21mm ceramic face, flow
Models in this guide
These are alternatives. Pick the one that fits your project; you only need one.
Option 128kHz 60W Ultrasonic Cleaning Transducer₹1,009
Option 240kHz 60W Ultrasonic Cleaning Transducer – Stainless Steel₹949
Option 368kHz 60W Ultrasonic Cleaning Transducer₹1,769
Option 4NU1ME21TR-1 21mm 1MHz Ultrasonic Flow & Distance Sensor – Ceramic Face, PWM Output, Lead Wire₹839
Option 5NU200E12TR-1 12mm 200kHz Ultrasonic Wind Speed Sensor₹6,609
Option 6NU200E12TR-1G2 12mm 200kHz Ultrasonic Wind Speed Sensor – Stainless Steel IP68₹7,609
What the Ultrasonic cleaning transducers (28, 40, 68kHz) and NU series 75kHz, 200kHz and 1MHz transducers is
Ultrasonic cleaning and high-frequency transducers are piezo elements (often 28 to 40 kHz) driven by a generator board to clean parts, atomise or weld.
Cleaning transducers need a generator tuned to their frequency; driving them from a function generator or a small audio amplifier will not work and can overheat them. Bond them with a thin layer of high-temperature epoxy on a clean, flat tank floor, and never run the tank dry.
Sensing transducers are driven with a short burst at their frequency and listened to for the echo or the transit time. Use a pulser and a low-noise amplifier stage, and keep the cable short and shielded.
Ultrasonic cleaning transducers (28, 40, 68kHz) and NU series 75kHz, 200kHz and 1MHz transducers pinout
The pins on the Ultrasonic cleaning transducers (28, 40, 68kHz) and NU series 75kHz, 200kHz and 1MHz transducers and what each one does.
| Pin | Function |
|---|---|
| Two leads | Piezo electrodes (cleaning) |
| Ground electrode | Bolted to the metal face |
| Signal leads | Sensing transducers |
| Shield | On cabled probes |
| Thread | Mounting on NU probes |
- Two leads
- Piezo electrodes (cleaning)
- Ground electrode
- Bolted to the metal face
- Signal leads
- Sensing transducers
- Shield
- On cabled probes
- Thread
- Mounting on NU probes
Wiring the Ultrasonic cleaning transducers (28, 40, 68kHz) and NU series 75kHz, 200kHz and 1MHz transducers
Cleaning generators run at high voltage; keep them enclosed and earth the tank.
| Ultrasonic cleaning transducers (28, 40, 68kHz) and NU series 75kHz, 200kHz and 1MHz transducers pin | Connection | Note |
|---|---|---|
| Cleaning transducer | Matched generator output | Correct frequency and power |
| Several transducers | In parallel | Same frequency |
| NU transducer | Pulser and receiver | Burst at resonance |
- Cleaning transducer
- Connection:
- Matched generator output
- Note:
- Correct frequency and power
- Several transducers
- Connection:
- In parallel
- Note:
- Same frequency
- NU transducer
- Connection:
- Pulser and receiver
- Note:
- Burst at resonance
Example code
Degas fresh water by running the tank for a few minutes before cleaning parts.
1. Choose frequency: 40kHz for general cleaning.
2. Clean and roughen the tank floor, then degrease.
3. Bond transducers with high-temperature epoxy, evenly spaced, and cure fully.
4. Wire them in parallel to a matched 40kHz generator of the same total power.
5. Fill the tank with water and a little detergent before switching on.
6. Never run the generator with the tank empty.Setup and tuning
use a matched generator board at the transducer's resonant frequency.
bond transducers to the tank with epoxy as specified.
never run without liquid in the tank.
generator boards often run on mains; build in an enclosure with proper insulation.
do not put hands in the tank while running.
What you need
Shop this list8 of 8 found in our store · ₹25,029
Generic 28kHz 60W Ultrasonic Cleaning Transducer: the part this guide covers28kHz 60W Ultrasonic Cleaning Transducer₹1,009
Generic 40kHz 60W Ultrasonic Cleaning Transducer – Stainless Steel: another version this guide covers40kHz 60W Ultrasonic Cleaning Transducer – Stainless Steel₹949
Generic 68kHz 60W Ultrasonic Cleaning Transducer: another version this guide covers68kHz 60W Ultrasonic Cleaning Transducer₹1,769
NU1ME21TR-1 21mm 1MHz Ultrasonic Flow & Distance Sensor – Ceramic Face, PWM Output, Lead Wire: another version this guide coversNU1ME21TR-1 21mm 1MHz Ultrasonic Flow & Distance Sensor – Ceramic Face, PWM Output, Lead Wire₹839
NU200E12TR-1 12mm 200kHz Ultrasonic Wind Speed Sensor: another version this guide coversNU200E12TR-1 12mm 200kHz Ultrasonic Wind Speed Sensor₹6,609
NU200E12TR-1G2 12mm 200kHz Ultrasonic Wind Speed Sensor – Stainless Steel IP68: another version this guide coversNU200E12TR-1G2 12mm 200kHz Ultrasonic Wind Speed Sensor – Stainless Steel IP68₹7,609
NU200E18TR-1 18mm 200kHz Ultrasonic Distance Sensor: another version this guide coversNU200E18TR-1 18mm 200kHz Ultrasonic Distance Sensor₹2,309
NU75E40TR-1 40mm 75kHz Ultrasonic Proximity Sensor: another version this guide coversNU75E40TR-1 40mm 75kHz Ultrasonic Proximity Sensor₹3,936
Alternatives and when to choose them
- 40kHz ultrasonic transducers: small distance transducers.
- Ultrasonic mist maker: 1.7MHz atomisers.
- Wind speed sensors: ultrasonic wind sensors.
Common mistakes to avoid
- Running dry.
- Mismatched generator frequency.
- Unsafe mains wiring.
- Poor epoxy bonding.
Frequently asked questions
What frequency should I use for cleaning?
About 40 kHz for general cleaning; 28 kHz for heavy dirt.
Can I run the transducer without water?
No. Without liquid the transducer overheats and can crack.
Why is cleaning weak?
The generator is not tuned to resonance or bonding is poor.
Can I build my own cleaner?
Yes, with a matched generator, bonded transducers and safe mains wiring.
Is it safe to touch the liquid?
Avoid putting hands in the liquid while it runs, as cavitation can harm skin.
Parts for this guide
Projects that use it
Put this into practice: 21 step-by-step builds in our project library use parts from this guide.
Keep learning
Sources
Written by the Geekobot team from manufacturer datasheets. Always check the datasheet for the exact part and variant you buy.