Wire gauge sets how much current a wire can carry safely: the lower the AWG number, the thicker the wire. For signals, 22 to 28 AWG is fine. For 2 to 5 A use 20 to 18 AWG, for 10 A about 16 to 14 AWG, and for 30 A battery leads 14 to 12 AWG silicone wire. Long runs need thicker wire to limit voltage drop.
Key specs at a glance
- 28 AWG
- 0.08 mm², signals, about 0.5 A
- 22 AWG
- 0.33 mm², breadboard hook-up, about 1 to 2 A
- 18 AWG
- 0.82 mm², about 5 to 7 A
- 14 AWG
- 2.1 mm², about 15 A
- 12 AWG
- 3.3 mm², about 20 A (more in silicone, short runs)
- Rule
- Each 3 AWG step thinner halves the area and doubles resistance
AWG chart with practical current guide
Current values are conservative figures for short hobby wiring in free air; enclosed bundles and mains wiring follow stricter rules.
| AWG | Diameter (solid) | Area | Resistance per metre | Practical current |
|---|---|---|---|---|
| 28 | 0.32 mm | 0.08 mm² | 0.21 Ω | 0.5 A |
| 26 | 0.40 mm | 0.13 mm² | 0.13 Ω | 1 A |
| 24 | 0.51 mm | 0.20 mm² | 0.084 Ω | 1.5 A |
| 22 | 0.64 mm | 0.33 mm² | 0.053 Ω | 2 A |
| 20 | 0.81 mm | 0.52 mm² | 0.033 Ω | 3 to 5 A |
| 18 | 1.02 mm | 0.82 mm² | 0.021 Ω | 5 to 7 A |
| 16 | 1.29 mm | 1.31 mm² | 0.013 Ω | 8 to 10 A |
| 14 | 1.63 mm | 2.08 mm² | 0.0083 Ω | 12 to 15 A |
| 12 | 2.05 mm | 3.31 mm² | 0.0052 Ω | 20 A |
| 10 | 2.59 mm | 5.26 mm² | 0.0033 Ω | 30 A |
- 28
- Diameter (solid):
- 0.32 mm
- Area:
- 0.08 mm²
- Resistance per metre:
- 0.21 Ω
- Practical current:
- 0.5 A
- 26
- Diameter (solid):
- 0.40 mm
- Area:
- 0.13 mm²
- Resistance per metre:
- 0.13 Ω
- Practical current:
- 1 A
- 24
- Diameter (solid):
- 0.51 mm
- Area:
- 0.20 mm²
- Resistance per metre:
- 0.084 Ω
- Practical current:
- 1.5 A
- 22
- Diameter (solid):
- 0.64 mm
- Area:
- 0.33 mm²
- Resistance per metre:
- 0.053 Ω
- Practical current:
- 2 A
- 20
- Diameter (solid):
- 0.81 mm
- Area:
- 0.52 mm²
- Resistance per metre:
- 0.033 Ω
- Practical current:
- 3 to 5 A
- 18
- Diameter (solid):
- 1.02 mm
- Area:
- 0.82 mm²
- Resistance per metre:
- 0.021 Ω
- Practical current:
- 5 to 7 A
- 16
- Diameter (solid):
- 1.29 mm
- Area:
- 1.31 mm²
- Resistance per metre:
- 0.013 Ω
- Practical current:
- 8 to 10 A
- 14
- Diameter (solid):
- 1.63 mm
- Area:
- 2.08 mm²
- Resistance per metre:
- 0.0083 Ω
- Practical current:
- 12 to 15 A
- 12
- Diameter (solid):
- 2.05 mm
- Area:
- 3.31 mm²
- Resistance per metre:
- 0.0052 Ω
- Practical current:
- 20 A
- 10
- Diameter (solid):
- 2.59 mm
- Area:
- 5.26 mm²
- Resistance per metre:
- 0.0033 Ω
- Practical current:
- 30 A
Voltage drop: why length matters
Current flows out and back, so the drop is current x resistance per metre x twice the length. A 12 V LED strip drawing 5 A through 3 m of 20 AWG wire loses 5 x 0.033 x 6 = 1 V, so the far end sees 11 V and dims. At 5 V the same loss is 20%. Fix it with thicker wire, shorter runs, or by feeding power at both ends. The voltage drop calculator and wire gauge calculator work it out for you.
Solid vs stranded, PVC vs silicone
holds its shape and pushes into breadboards and terminal blocks. It breaks if flexed repeatedly. Good for breadboards and fixed wiring inside boxes.
flexible and survives vibration. Use it for anything that moves (robots, cables to sensors) and tin or ferrule the ends before clamping.
cheap and common; melts near a soldering iron.
very flexible, heat resistant (about 200 °C) and the standard for batteries, drones and motors.
In India, mains house wiring is sold in mm² (1, 1.5, 2.5 mm²) and must follow electrical codes; this guide is about low-voltage project wiring.
Try it: Wire gauge calculator
Change the values and the diagram and results update as you type.
Common mistakes to avoid
- Sizing wire by the voltage instead of the current.
- Ignoring the return path when estimating voltage drop.
- Using solid-core wire on moving parts.
- Clamping bare stranded wire in screw terminals without tinning or ferrules.
- Running battery leads through thin breadboard jumpers.
Frequently asked questions
What gauge wire do I need for 10 amps?
About 16 to 14 AWG for short low-voltage runs. Use thicker wire for long runs or enclosed bundles.
Is a lower AWG number thicker?
Yes. 12 AWG is much thicker than 22 AWG. Every three steps down roughly doubles the copper area.
What wire should I use for a breadboard?
22 AWG solid-core hook-up wire, or ready-made jumper wires.
Why use silicone wire for batteries?
It is very flexible, survives heat from soldering and high currents, and resists vibration, which suits batteries, drones and robots.
How do I convert AWG to mm²?
Use a chart: 22 AWG is about 0.33 mm², 18 AWG about 0.82 mm², 14 AWG about 2.08 mm² and 12 AWG about 3.31 mm².