Shop by category
Shop all componentsWiring & PCB
Rule-of-thumb values for PVC-insulated copper. Silicone wire and short runs can carry more; mains wiring must follow IS 732 and the cable maker’s rating.
d (mm) = 0.127 × 92^((36 − AWG) ÷ 39)A = π ÷ 4 × d²R per m = ρ ÷ A, ρ copper = 1.724 × 10⁻⁸ Ω·m18 AWG: d = 0.127 × 92^(18/39) = 1.02 mm, area 0.823 mm², 21 mΩ per metre. Good for about 16 A in short chassis wiring, 2.3 A in long bundled runs.
AWG (American Wire Gauge) numbers go down as wire gets thicker: every 3 gauges halves the area, every 6 gauges halves the diameter. Indian and European cables are sold by cross-section in mm², so this calculator gives both.
How much current a wire can carry depends on how well it can get rid of heat, so short single wires in open air can take far more than long bundled cables. For battery leads, motors and LED strips, also check the voltage drop: a wire can be safe for the current but still lose too much voltage.
For short runs in free air, 1.5 mm² (about 16 AWG) copper is common for 10 A. Long runs need thicker wire to limit voltage drop.
Use the calculator. Common pairs: 22 AWG ≈ 0.33 mm², 18 AWG ≈ 0.82 mm², 14 AWG ≈ 2.1 mm².
Yes. Each step down in AWG makes the wire thicker; 3 steps roughly double the cross-section.
d (mm) = 0.127 × 92^((36 − AWG) ÷ 39); A = π ÷ 4 × d²; R per m = ρ ÷ A, ρ copper = 1.724 × 10⁻⁸ Ω·m.
18 AWG: d = 0.127 × 92^(18/39) = 1.02 mm, area 0.823 mm², 21 mΩ per metre. Good for about 16 A in short chassis wiring, 2.3 A in long bundled runs.
Geekobot builds that use it include Wi-Fi smart switch, Pico W Wi-Fi switch (MicroPython), Touch lamp switch and Wi-Fi dusk light with manual override. Each has the full parts list, wiring and code.
Results are estimates for design and learning. Check critical designs against the component datasheet. Made by the Geekobot Learning Team. How we write our calculators