Shop by category
Shop all componentsWiring & PCB
A (mil²) = (I ÷ (k × ΔT^0.44))^(1 ÷ 0.725)Width = A ÷ (1.378 × oz)k = 0.048 external, 0.024 internal1 A, 10 °C rise, 1 oz external copper: A = (1 ÷ (0.048 × 10^0.44))^1.379 = 16.3 mil², width = 16.3 ÷ 1.378 = 11.8 mil = 0.30 mm.
A PCB trace is a flat wire, and like any wire it heats up with current. The IPC-2221 chart, captured in this formula, gives the cross-section needed to keep the temperature rise within your limit. Internal layers are surrounded by board material and need about twice the width.
Width is only part of the story: also check the voltage drop over long traces, and widen power and ground traces generously when there is space. Most hobby PCB services default to 1 oz copper; 2 oz costs a little more and halves the width needed.
On 1 oz outer copper with a 10 °C rise, about 0.3 mm (12 mil). Inner layers need roughly twice the width.
They are surrounded by board material and cannot shed heat to air, so IPC-2221 uses half the k factor.
1 ounce of copper spread over a square foot, about 35 µm thick. 2 oz copper halves the width needed.
A (mil²) = (I ÷ (k × ΔT^0.44))^(1 ÷ 0.725); Width = A ÷ (1.378 × oz); k = 0.048 external, 0.024 internal.
1 A, 10 °C rise, 1 oz external copper: A = (1 ÷ (0.048 × 10^0.44))^1.379 = 16.3 mil², width = 16.3 ÷ 1.378 = 11.8 mil = 0.30 mm.
Results are estimates for design and learning. Check critical designs against the component datasheet. Made by the Geekobot Learning Team. How we write our calculators