Shop all componentsCO2 rises when many people share a closed room, and high CO2 makes people sleepy. NDIR transmitters measure it accurately. The SN-3002-CO2-N01 reports 0-5000 ppm over RS485 Modbus. The ESP32 reads it and shows ppm on an OLED with OK below 800 ppm, AIR OUT to 1200 ppm and OPEN WINDOWS above. RS485 sensors from different makers use different default addresses, baud rates and register numbers. The values in the sketch are typical defaults; check them against the manual that came with your sensor before you rely on the readings.
Keep the 12 V supply wiring inside a closed box.
Tick anything you already have and the total updates.
SN-3002-CO2-N01 RS485 CO2 transmitter
Follow the colours: red is power, dark grey is ground, blue is a signal.
12 V adapter for the transmitter; the ESP32 runs from it through the 5 V buck.
rs485_co2.inoVerify & upload in Electrolark#include <ModbusMaster.h>
#include <Adafruit_SSD1306.h>
// From the sensor's manual: address, baud and the register to read
const uint8_t ADDR = 1;
const long BAUD = 4800;
const uint16_t REG = 0x0002; // CO2 in ppm on many transmitters
const float SCALE = 1;
ModbusMaster node;
Adafruit_SSD1306 oled(128, 64, &Wire, -1);
const int DE_RE = 4;
void preTx() { digitalWrite(DE_RE, HIGH); }
void postTx() { digitalWrite(DE_RE, LOW); }
void setup() {
Serial.begin(115200);
Serial2.begin(BAUD, SERIAL_8N1, 16, 17); // RX, TX to the MAX3485
pinMode(DE_RE, OUTPUT); postTx();
node.begin(ADDR, Serial2);
node.preTransmission(preTx);
node.postTransmission(postTx);
oled.begin(SSD1306_SWITCHCAPVCC, 0x3C);
}
void loop() {
uint8_t r = node.readHoldingRegisters(REG, 1);
oled.clearDisplay(); oled.setTextColor(WHITE); oled.setTextSize(2); oled.setCursor(0, 10);
if (r == node.ku8MBSuccess) {
int ppm = node.getResponseBuffer(0) * SCALE;
oled.print(ppm); oled.println(" ppm");
oled.setTextSize(1); oled.print(ppm < 800 ? "OK" : ppm < 1200 ? "AIR OUT" : "OPEN WINDOWS");
} else {
oled.setTextSize(1); oled.print("No reply, code "); oled.print(r, HEX);
}
oled.display();
delay(2000);
}
Check baud, address and A/B; many transmitters default to 4800 or 9600 baud.
Give it 10-20 minutes to warm up after power-on.
You are reading the wrong register; check the manual's register table.
Below about 800-1000 ppm means the room is well ventilated.
Yes, NDIR measures CO2 directly; MQ sensors only estimate it.
Yes, add Wi-Fi and post readings to your server.
8 parts: SN-3002-CO2-N01 Carbon Dioxide Sensor (0-5000ppm) – RS485 Modbus, MAX3485 TTL to RS485 Converter Module – 3.3V Logic, ESP32-WROOM-32 38-Pin Development Board, 0.96" OLED Display 128x64, Step-Down Converter to 5V USB / 5V 3A, DC Power Adapter (5.5x2.1mm), Solderless Breadboard and Dupont Jumper Wires (40 pcs). On this page you can tick the parts you already have and add only the rest to your cart.
It is a intermediate project and takes about 3 hours. The build on this page has 7 steps.
No. This page has the complete, tested code (rs485_co2.ino).
About ₹3,653 for the parts at the prices on this page. Quantity price breaks lower the cost when you build several.
NDIR CO2 measurement; Modbus RTU over RS485; Turning a reading into a simple traffic-light signal.
Keep the 12 V supply wiring inside a closed box.
A kitchen gas sniffer that beeps and flashes the moment LPG levels climb.
See the smoke level live on a crisp screen and get a loud warning when it spikes.
An infrared eye that spots an open flame and raises the alarm.
Walk into the room and it sounds the alarm: the classic first security build.
Lessons are free to read. Maker (₹499/month) and Pro add quizzes, worked problems and certificates, paid with your Geekobot account. See plans
Learning project. Check every circuit and the datasheet of each part before you power it up.