Shop by category
Shop all componentsPower, batteries & solar
Ratings are at full load. An unloaded small transformer reads 10–20% above its rated secondary voltage.
Np ÷ Ns = Vp ÷ VsI s = VA ÷ Vs, I p = VA ÷ VpV dc ≈ Vs × √2 − 1.4 VA 230 V to 12 V, 24 VA transformer: ratio 19.2 : 1, secondary 2 A, primary 0.104 A, and about 15.6 V DC after a bridge rectifier and filter capacitor.
A transformer’s voltage ratio is its turns ratio, while current runs the opposite way: a step-down transformer gives more current on the secondary than it draws on the primary.
The VA rating limits the product of voltage and current. For a rectified supply, choose a transformer whose current rating is about 1.5 to 2 times the DC current you need, because the rectifier and capacitor draw current in short peaks.
Np ÷ Ns = Vp ÷ Vs. A 230 V to 12 V transformer has about a 19:1 ratio.
Its VA rating is 24 VA. After rectifying and filtering, plan on about 60 % of the AC current as DC load.
The primary is at mains voltage. Use insulated terminals, a fuse and an enclosure, and ask a qualified electrician if unsure.
Np ÷ Ns = Vp ÷ Vs; I s = VA ÷ Vs, I p = VA ÷ Vp; V dc ≈ Vs × √2 − 1.4 V.
A 230 V to 12 V, 24 VA transformer: ratio 19.2 : 1, secondary 2 A, primary 0.104 A, and about 15.6 V DC after a bridge rectifier and filter capacitor.
Geekobot builds that use it include Solder a fused 12 V to 5 V power board on stripboard and 12 V solar battery monitor: volts, amps and amp-hours. Each has the full parts list, wiring and code.
Results are estimates for design and learning. Check critical designs against the component datasheet. Made by the Geekobot Learning Team. How we write our calculators