Usable energy = V × Ah × depth × ηBackup time = usable energy ÷ loadBattery current = load ÷ (V × η)A 12 V, 150 Ah lead-acid battery (50% usable) with an 85% efficient inverter powering 300 W: 12 × 150 × 0.5 × 0.85 = 765 Wh, so 2.5 hours. A 4 hour backup needs about 235 Ah.
Backup time depends on the battery’s usable energy, the inverter’s losses and your load. Only part of a lead-acid battery’s capacity should be used if you want it to last for years, and the faster you discharge it, the less you get out (the Peukert effect).
Add up only the loads that must keep running, such as lights, a router and a few fans. Heaters, irons and motors with high starting current need a much larger inverter and bank.
At 12 V, 150 Ah, 80 % usable and 85 % efficiency there is about 1.2 kWh, so a 300 W load runs about 4 hours.
Ah = load W × hours ÷ (battery V × depth of discharge × efficiency).
Deep discharges shorten its life. Keep tubular and flat-plate batteries above about 50 % for long service.
Usable energy = V × Ah × depth × η; Backup time = usable energy ÷ load; Battery current = load ÷ (V × η).